44 en Configuring the System

High Speed Pan/Tilt System

 

 

Preset Menu

The Preset menu displays and allows changes to all parameters for the available preset posi- tions in the UPH. Use the up and down function of the joystick to move between the presets in units, i.e.: PRST 01 to PRST 02 to PRST 03. Use the left and right function of the joystick to move between the presets in tens, i.e.: PRST 01 to PRST 11 to PRST 21. Press Focus to edit the chosen preset, using the joystick and Focus button to fine tune these parameters. Use the Iris button to exit.

 

PRESET EDIT MENU

 

PRST

PAN

:

+ 0.0

01

TILT

:

+ 0.0

 

ENABLE

:

NO

 

ZOOM

:

00000

 

FOCUS

:

00000

 

IRIS

:

00000

 

SPEED

:

040.0

 

DWELL

:

00001

 

TXT: PRESET NR. 1

 

 

 

Fig. 11.12 Preset Menu

 

Feature

Description

Default

Options

 

 

 

 

PAN

Moves a camera on a horizontal

0.0

-180.00°-

 

axis.

 

+180.00°

 

 

 

 

TILT

Moves a camera on a vertical axis.

0.0

-40.00°-

 

 

 

+90.00°

 

 

 

 

ENABLE

Enables preset.

NO

YES, NO

 

 

 

 

ZOOM

Changing the effective focal length

00000

65535

 

to allow different fields of view to

 

 

 

fill the picture area. Zoom can be

 

 

 

optical, where the lens is adjusted,

 

 

 

or digital, where a portion of the

 

 

 

view selected is magnified elec-

 

 

 

tronically.

 

 

 

 

 

 

FOCUS

Positions

00000

65535

 

 

 

 

IRIS

Positions

00000

65535

 

 

 

 

SPEED

Speed for reaching the position

040.0

.1 - 100.0°

 

when the preset position is loaded

 

 

 

by the patrol function.

 

 

 

 

 

 

DWELL

Dwell time during patrol and auto-

00001

00000 -

 

pan movements.

 

01000 sec.

 

 

 

 

TXT: PRESET NR. 1

Message displayed when the pre-

 

 

 

set position is reached.

 

 

 

 

 

 

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 44
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksParts List 2UnpackingTools Required Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionWarranties are void Installing the High Speed Pan/TiltMounting the High Speed Pan/Tilt Description Outdoor Pole Mount for UPH SeriesOutdoor Wall Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesConnecting the Power Supply That the disconnecting switch is openWire Color VAC Terminal Connection Per local Installer Neutral Live/Active Green/Yellow Earth5RS-232 Wiring BiphaseRS-232 is used for firmware upgrades only see Figure Connecting the Washer Pump optional Washer Pipe NutNosecap CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsMetal Fixing Accessory Attaching the Top UnitSalt Bag Fixing ScrewsAligning the Tabs Configuration Window Place safety label near unit that warns of moving partsScrew Screw SealConfiguring the Device Baud Rate SwitchesRocker for DIP switch No is OFF PROGRAM. OFF For updating the firmwareProtocol Switches Setting the AddressProtocol Baud Rate Menu setup OSD Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections RS-485 Divar Biphase RS-485 Biphase Bilinx/Video IntuikeyboardIntuikeyboard AllegiantRS485-2 EthernetEthernet VideoTo configure the UPH, proceed as follows Switching On and OffConfiguring the Device Using the Joystick On-screen Display OSDMoving Around the Menus Open or Iris Close button10.1 Keyboard Commands List Setup and ConfigurationPresets Auxiliary ConnectionsConfiguring the System 10.2 Changing the Settings10.3 Changing the Numeric Fields Main menu by pressing AUX on 200 EnterPlayed on the screen 11.2 Display Setup Menu11.1 Language Menu Feature Description Default Options Enables / disables the on-screen message By the device Enables the user to edit a customized, onArea Parameters Menu Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset PanSpeed Menu Wiper-washer, and the alarm settings of the UPH11.3 Motion Parameters Menu Tilt Speed Data is expressed as degrees per secondPAN Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedPatrol loading of preset positions Start PositionEND Position First Prst SpeedMotions Recall Menu Autopan menu is used to indicate preset position settingsAutopan Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuDynamic Masking UPH-Z Series only Parameters Mode Infrared MenuAuto Exposure Parameters Menu Mask NR Mask ChangingPosition Recall Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskImage Stabilization Back Light CompenSAT 11.6 Load Default Configuration 11.7 Setup Info MenuLoad Default menu is used to load the default settings UPH boardsMaintenance 12.1 Cleaning12.2 Replacing the Fuses Voltage Fuse F1 Fuse F2Troubleshooting Error TroubleshootingProblem Possible Cause Solution 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems