Bosch Appliances UPH-2D, UPH-Z, UPH-3D instruction manual Limits

Page 42

42 en Configuring the System

High Speed Pan/Tilt System

 

 

11.3.2Limits

The Limits menu sets the movement limits for the UPH. These limits apply to all presets, auto- pan and patrols, including manual operation of the UPH using the joystick. After the limits are set in the OSD and the UPH moves into the "limited pan and tilt zone", it will not move outside of those limits until they are altered in the OSD or the UPH is reset. On reset, the UPH returns to within the limited pan and tilt zone.

LIMITS MENU

 

 

1

- ENABLE PAN LIM.

:

NO

2

- START PAN

: +

0.00

3

- END PAN

: +

0.00

4

- ENABLE TILT LIM.

:

NO

5

- START TILT

: +

0.00

6

- END TILT

: +

0.00

7

- COMPL. ROTATION

:

YES

8

- RAMP TYPE

:

012

Fig. 11.10 Limits Menu

.

Feature

Description

Default

Options

 

 

 

 

ENABLE PAN LIM.

Enables limits and values in

NO

YES, NO

 

degrees taken by the device in

 

 

 

pan.

 

 

 

Enables or disables complete rota-

 

 

 

tion for scan/patrol/autopan move-

 

 

 

ments (this function is useful when

 

 

 

using accessories with external

 

 

 

cables, such as infrared spotlights,

 

 

 

where continuous rotation of the

 

 

 

UPH could break the accessories

 

 

 

themselves).

 

 

 

 

 

 

START PAN

Enables the location that the UPH

+0.00

-180.00°-

 

begins to pan.

 

+180.00°

 

 

 

 

 

 

 

END PAN

Enables the location that the UPH

+0.00

-180.00°-

 

stops panning.

 

+180.00°

 

 

 

 

 

 

 

ENABLE TILT LIM.

Enables limits and values in

NO

YES, NO

 

degrees taken by the device in tilt.

 

 

 

 

 

 

START TILT

Enables the location that the UPH

+0.00

-40.00°-

 

begins to tilt.

 

+90.00°

 

 

 

 

 

 

 

END TILT

Enables the location that the UPH

+0.00

-40.00°-

 

stops tilting.

 

+90.00°

 

 

 

 

 

 

 

COMPL. ROTATION

Enables the search for the shortest

YES

YES, NO

 

route during scan, patrol, and

 

 

 

autopan movements.

 

 

 

 

 

 

RAMP TYPE

Changes start and stop times for

012

000 - 012

 

the UPH. The higher the number,

 

 

 

the greater the acceleration/decel-

 

 

 

eration during starting/stopping.

 

 

 

 

 

 

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 42
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksTools Required Parts List2Unpacking Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionInstalling the High Speed Pan/Tilt Mounting the High Speed Pan/TiltWarranties are void Outdoor Wall Mount for UPH Series DescriptionOutdoor Pole Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesWire Color VAC Terminal Connection Connecting the Power SupplyThat the disconnecting switch is open Per local Installer Neutral Live/Active Green/Yellow EarthWiring Biphase RS-232 is used for firmware upgrades only see Figure5RS-232 Connecting the Washer Pump optional Nosecap Washer PipeNut CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsSalt Bag Metal Fixing AccessoryAttaching the Top Unit Fixing ScrewsAligning the Tabs Screw Configuration WindowPlace safety label near unit that warns of moving parts Screw SealRocker for DIP switch No is OFF PROGRAM. OFF Configuring the DeviceBaud Rate Switches For updating the firmwareProtocol Baud Rate Menu setup OSD Protocol SwitchesSetting the Address Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections Intuikeyboard RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard AllegiantRS485-2 EthernetEthernet VideoSwitching On and Off Configuring the DeviceTo configure the UPH, proceed as follows Moving Around the Menus Using the JoystickOn-screen Display OSD Open or Iris Close buttonPresets 10.1 Keyboard Commands ListSetup and Configuration Auxiliary Connections10.3 Changing the Numeric Fields Configuring the System10.2 Changing the Settings Main menu by pressing AUX on 200 Enter11.2 Display Setup Menu 11.1 Language MenuPlayed on the screen Feature Description Default Options Area Parameters Menu Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset PanWiper-washer, and the alarm settings of the UPH 11.3 Motion Parameters MenuSpeed Menu Data is expressed as degrees per second PAN SpeedTilt Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedEND Position Patrol loading of preset positionsStart Position First Prst SpeedAutopan menu is used to indicate preset position settings AutopanMotions Recall Menu Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuParameters Mode Infrared Menu Auto Exposure Parameters MenuDynamic Masking UPH-Z Series only Position Recall Mask NRMask Changing Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskBack Light Compen SATImage Stabilization Load Default menu is used to load the default settings 11.6 Load Default Configuration11.7 Setup Info Menu UPH boards12.2 Replacing the Fuses Maintenance12.1 Cleaning Voltage Fuse F1 Fuse F2Troubleshooting Problem Possible Cause SolutionTroubleshooting Error 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems