Patrol (loading of preset positions)

The Patrol menu is a defined path from preset to preset. This can be from two (2) presets up to 250. For example, the random option allows various presets such as preset 4, then preset 1, then preset 8, then preset 3.

PATROL MENU

 

 

 1

- START POSITION

:

00001

2

- END POSITION

:

00250

3

- FIRST PRST SPEED

:

20.0

4

- RANDOM

:

NO

Fig. 11.14 Patrol Menu

Feature

Description

Default

Options

 

 

 

 

START POSITION

The first preset position consid-

00001

00001 -

 

ered valid for carrying out the

 

00250

 

patrol function.

 

 

 

 

 

 

END POSITION

The last preset position consid-

00250

00001 -

 

ered valid for carrying out the

 

00250

 

patrol function.

 

 

 

 

 

 

FIRST PRST SPEED

Speed at which the UPH reachs

20.0

01 - 100.0°

 

the first preset position when the

 

 

 

patrol function is activated.

 

 

 

Increase the First PRST Speed

 

 

 

from the default value to reach

 

 

 

presets faster.

 

 

 

 

 

 

RANDOM

Enables execution of the Patrol

NO

YES, NO

 

function by passing through the

 

 

 

defined positions in a random

 

 

 

manner. The random sequence is

 

 

 

continually recalculated.

 

 

 

 

 

 

Bosch Security Systems

Instruction Manual

F01U.073.990 Version 1.0 2007.07

Image 47
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Important safety instructions SafetySafety precautions Coax grounding Important noticesTrademarks CopyrightSmall, straight-blade screwdriver 2.5 mm 0.1 Parts List2Unpacking Tools Required3Description Safety RulesWarranties are void Installing the High Speed Pan/TiltMounting the High Speed Pan/Tilt Pole Adapter for MTC-WUPH DescriptionOutdoor Pole Mount for UPH Series Outdoor Wall Mount for UPH SeriesBase Gasket Screw Ring Washer Bracket Support Reference # DescriptionTie Threads used to Group and Secure Signal Cables Wiring the Video CablePer local Installer Neutral Live/Active Green/Yellow Earth Connecting the Power SupplyThat the disconnecting switch is open Wire Color VAC Terminal Connection5RS-232 Wiring BiphaseRS-232 is used for firmware upgrades only see Figure Connecting the Washer Pump optional Coupling Washer PipeNut NosecapCalibrating the Nozzle AL1 Reference DescriptionBase with 19-pin Connector for Connecting Peripherals Connecting the PeripheralsFixing Screws Metal Fixing AccessoryAttaching the Top Unit Salt BagAligning the Tabs Screw Seal Configuration WindowPlace safety label near unit that warns of moving parts ScrewFor updating the firmware Configuring the DeviceBaud Rate Switches Rocker for DIP switch No is OFF PROGRAM. OFFPelco D 2400 Preset Biphase Auto AUX-On Bilinx Protocol SwitchesSetting the Address Protocol Baud Rate Menu setup OSDAddress Combinations 4Connections Allegiant RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard IntuikeyboardEthernetEthernet Video RS485-2To configure the UPH, proceed as follows Switching On and OffConfiguring the Device Open or Iris Close button Using the JoystickOn-screen Display OSD Moving Around the MenusAuxiliary Connections 10.1 Keyboard Commands ListSetup and Configuration PresetsMain menu by pressing AUX on 200 Enter Configuring the System10.2 Changing the Settings 10.3 Changing the Numeric FieldsPlayed on the screen 11.2 Display Setup Menu11.1 Language Menu Feature Description Default Options Depending on the horizontal position reached Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Area Parameters MenuChanging the Edit Text Menu Setting the Area Position ValuesOffset Pan Display ParametersSpeed Menu Wiper-washer, and the alarm settings of the UPH11.3 Motion Parameters Menu Tilt Speed Data is expressed as degrees per secondPAN Speed Limits Feature Description Preset/Patrol/AutopanPreset Menu Special Preset Parameters Reached Speed Home PositionFirst Prst Speed Patrol loading of preset positionsStart Position END PositionMotions Recall Menu Autopan menu is used to indicate preset position settingsAutopan Wiper-Washer 11.4 Camera Parameters AlarmsUPH-2D and UPH-3D Series DinionXF Cameras Zoom Parameters Menu UPH-Z Series camera moduleFocus Parameters Menu Focus Parameters menu is used to enable focus settingsDynamic Masking UPH-Z Series only Parameters Mode Infrared MenuAuto Exposure Parameters Menu Changing Colour Mask NRMask Changing Position Recall11.5 Creating a New Dynamic Mask PTZ Mode MaskingImage Stabilization Back Light CompenSAT UPH boards 11.6 Load Default Configuration11.7 Setup Info Menu Load Default menu is used to load the default settingsVoltage Fuse F1 Fuse F2 Maintenance12.1 Cleaning 12.2 Replacing the FusesTroubleshooting Error TroubleshootingProblem Possible Cause Solution 514 584 13.1 Dimensions and Range of MovementR385 Technical Specifications Bosch Security Systems