28 en Configuring the Device

High Speed Pan/Tilt System

 

 

7.4Connections

Please take note of the particular UPH model that you have installed. All three versions, UPH- Z, UPH-2D, and UPH-3D Series, support Bilinx and Biphase telemetry control, i.e.: PTZ.

The camera menu setup of UPH-Z Series is done via the OSD, i.e.: AUX ON - 200 - Enter. The camera menu setup of UPH-2D and UPH-3D Series is done via two different AUX commands, i.e.: AUX ON - 46 - Enter (DinionXF main menu) and AUX ON - 801 - Enter (DinionXF installa- tion menu). See Figure 10.1 for more information about keyboard commands.

Bilinx is a Bosch two-way communication protocol that allows remote control, configuration, and updates over a video coax cable. Bilinx is available on all UPH models.

Biphase is used for communicating telemetry (control) and set up information with the UPH- Series units. Biphase does not pass the video signal from the UPH-Series units, so a separate video coax cable is required. Biphase should be wired with Belden 8760 or equivalent.

Biphase is available on all UPH models.

Note: If the UPH is the only unit connected, or the last unit in a daisy chain configuration, then turn ON dip-switch 1 of Biphase + Bilinx to terminate the data line. Turn OFF dip-switch 1 of Biphase + Bilinx for each UPH in a daisy chain (i.e. unterminated). A maximum of four (4) UPH units can be daisy chained together.

LTC5136 or equivalent

RS-232

 

Interface

 

Biphase

 

 

 

 

 

 

 

 

Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CCTV Monitor

Video

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPH Series: unitized pan/ tilt head

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 28 Contents
High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksParts List 2UnpackingTools Required Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionMounting the High Speed Pan/Tilt Installing the High Speed Pan/TiltWarranties are void Description Outdoor Pole Mount for UPH SeriesOutdoor Wall Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesConnecting the Power Supply That the disconnecting switch is openWire Color VAC Terminal Connection Per local Installer Neutral Live/Active Green/Yellow EarthRS-232 is used for firmware upgrades only see Figure Wiring Biphase5RS-232 Connecting the Washer Pump optional Washer Pipe NutNosecap CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsMetal Fixing Accessory Attaching the Top UnitSalt Bag Fixing ScrewsAligning the Tabs Configuration Window Place safety label near unit that warns of moving partsScrew Screw Seal Configuring the Device Baud Rate Switches Rocker for DIP switch No is OFF PROGRAM. OFF For updating the firmwareProtocol Switches Setting the AddressProtocol Baud Rate Menu setup OSD Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections RS-485 Divar Biphase RS-485 Biphase Bilinx/Video IntuikeyboardIntuikeyboard AllegiantRS485-2 EthernetEthernet VideoConfiguring the Device Switching On and OffTo configure the UPH, proceed as follows Using the Joystick On-screen Display OSDMoving Around the Menus Open or Iris Close button10.1 Keyboard Commands List Setup and ConfigurationPresets Auxiliary ConnectionsConfiguring the System 10.2 Changing the Settings10.3 Changing the Numeric Fields Main menu by pressing AUX on 200 Enter11.1 Language Menu 11.2 Display Setup MenuPlayed on the screen Feature Description Default Options Enables / disables the on-screen message By the device Enables the user to edit a customized, onArea Parameters Menu Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset Pan11.3 Motion Parameters Menu Wiper-washer, and the alarm settings of the UPHSpeed Menu PAN Speed Data is expressed as degrees per secondTilt Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedPatrol loading of preset positions Start PositionEND Position First Prst SpeedAutopan Autopan menu is used to indicate preset position settingsMotions Recall Menu Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuAuto Exposure Parameters Menu Parameters Mode Infrared MenuDynamic Masking UPH-Z Series only Mask NR Mask ChangingPosition Recall Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskSAT Back Light CompenImage Stabilization 11.6 Load Default Configuration 11.7 Setup Info MenuLoad Default menu is used to load the default settings UPH boardsMaintenance 12.1 Cleaning12.2 Replacing the Fuses Voltage Fuse F1 Fuse F2Problem Possible Cause Solution TroubleshootingTroubleshooting Error 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems