High Speed Pan/Tilt System

Configuring the System en 39

 

 

The character being edited flashes and the joystick (up and down) can be used to change it. After making the change, confirm and continue to edit the text, or else exit with the Iris but- ton.

EDIT TEXT MENU

v _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

> 1ABC

2DEF

3GHI

4JKL

5MNO

6PQR

7STU

8VWX

9YZ

0()x

+,-.

 

Fig. 11.6 Edit Text Menu

Offset Pan

By default, the offset pan is +0.00. The value can be changed to move the default pan position of the unit to wherever is convenient. For example, if the installation requires that the NORTH position should be at 0.00 ° (pan), then an offset pan can be entered to compensate for any deviation from NORTH. After mounting, the NORTH position was found to be +41.37 ° (pan position); therefore, the offset pan should be set to - 41.37 ° to make the pan +0.00 ° position point to NORTH.

This has an effect on the Area Titles as defined in the Area Position menu. In the above exam- ple, after the offset pan has been set to -41.37 °, the Area Text Menu "1 - Area" could be changed to "1 - NORTH" to display NORTH on the screen at pan +0.00 ° position.

11.2.3Display Parameters

The Display Parameters menu is used to enter the settings menus for the device movement parameters.

DISPLAY PARAMETERS

 

 1

- OSD VIDEO ENABLING

: YES

2

- VIDEO CHARACTER TYPE

: 000

3

- HORIZONTAL DELTA

: 000

4

- VERTICAL DELTA

: 000

5

- ADDRSS NUMBER

YES

Fig. 11.7 Display Parameters Menu

OSD Video Enabling

Set to YES to superimpose the menu text over the video signal

 

from the camera. Set to NO to have a blue screen behind the

 

menu TEXT.

 

 

Video Character Type

Set to 0 to make the background of the text to transparent; set to

 

1 to make it black.

 

 

Horizontal Delta/Vertical

These set the position of reference to the titler so that the text

Delta

can be centralized.

 

 

Address Number

If enabled, the address number of the unit is shown at the top left

 

of the screen during normal operation.

 

 

Bosch Security Systems

Instruction Manual

F01U.073.990 Version 1.0 2007.07

Image 39
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Important safety instructions SafetySafety precautions Coax grounding Important noticesTrademarks CopyrightSmall, straight-blade screwdriver 2.5 mm 0.1 Parts List2Unpacking Tools Required3Description Safety RulesInstalling the High Speed Pan/Tilt Mounting the High Speed Pan/TiltWarranties are void Pole Adapter for MTC-WUPH DescriptionOutdoor Pole Mount for UPH Series Outdoor Wall Mount for UPH SeriesBase Gasket Screw Ring Washer Bracket Support Reference # DescriptionTie Threads used to Group and Secure Signal Cables Wiring the Video CablePer local Installer Neutral Live/Active Green/Yellow Earth Connecting the Power SupplyThat the disconnecting switch is open Wire Color VAC Terminal ConnectionWiring Biphase RS-232 is used for firmware upgrades only see Figure5RS-232 Connecting the Washer Pump optional Coupling Washer PipeNut NosecapCalibrating the Nozzle AL1 Reference DescriptionBase with 19-pin Connector for Connecting Peripherals Connecting the PeripheralsFixing Screws Metal Fixing AccessoryAttaching the Top Unit Salt BagAligning the Tabs Screw Seal Configuration WindowPlace safety label near unit that warns of moving parts ScrewFor updating the firmware Configuring the DeviceBaud Rate Switches Rocker for DIP switch No is OFF PROGRAM. OFFPelco D 2400 Preset Biphase Auto AUX-On Bilinx Protocol SwitchesSetting the Address Protocol Baud Rate Menu setup OSDAddress Combinations 4Connections Allegiant RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard IntuikeyboardEthernetEthernet Video RS485-2Switching On and Off Configuring the DeviceTo configure the UPH, proceed as follows Open or Iris Close button Using the JoystickOn-screen Display OSD Moving Around the MenusAuxiliary Connections 10.1 Keyboard Commands ListSetup and Configuration PresetsMain menu by pressing AUX on 200 Enter Configuring the System10.2 Changing the Settings 10.3 Changing the Numeric Fields11.2 Display Setup Menu 11.1 Language MenuPlayed on the screen Feature Description Default Options Depending on the horizontal position reached Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Area Parameters MenuChanging the Edit Text Menu Setting the Area Position ValuesOffset Pan Display ParametersWiper-washer, and the alarm settings of the UPH 11.3 Motion Parameters MenuSpeed Menu Data is expressed as degrees per second PAN SpeedTilt Speed Limits Feature Description Preset/Patrol/AutopanPreset Menu Special Preset Parameters Reached Speed Home PositionFirst Prst Speed Patrol loading of preset positionsStart Position END PositionAutopan menu is used to indicate preset position settings AutopanMotions Recall Menu Wiper-Washer 11.4 Camera Parameters AlarmsUPH-2D and UPH-3D Series DinionXF Cameras Zoom Parameters Menu UPH-Z Series camera moduleFocus Parameters Menu Focus Parameters menu is used to enable focus settingsParameters Mode Infrared Menu Auto Exposure Parameters MenuDynamic Masking UPH-Z Series only Changing Colour Mask NRMask Changing Position Recall11.5 Creating a New Dynamic Mask PTZ Mode MaskingBack Light Compen SATImage Stabilization UPH boards 11.6 Load Default Configuration11.7 Setup Info Menu Load Default menu is used to load the default settingsVoltage Fuse F1 Fuse F2 Maintenance12.1 Cleaning 12.2 Replacing the FusesTroubleshooting Problem Possible Cause SolutionTroubleshooting Error 514 584 13.1 Dimensions and Range of MovementR385 Technical Specifications Bosch Security Systems