Electrical Connection-U.S.A.Only
Power Supply Cord |
| Direct Wire |
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1. | Disconnect power. | 3. Install strain relief. |
2. | Remove the | Style 1: Power supply cord strain relief |
| A | ■ Remove the screws from a ³⁄₄" (1.9 cm) UL listed strain relief |
| (UL marking on strain relief). Put the tabs of the two clamp | |
|
| |
|
| sections into the hole below the terminal block opening so |
|
| that one tab is pointing up and the other is pointing down, and |
|
| hold in place. Tighten strain relief screw enough to hold the |
| B | two clamp sections together. |
| C | A |
|
| |
|
| B |
|
| C |
E | D | D |
|
A. Strain relief tab pointing up
A. Center, | B. Hole below terminal block opening | |
B. | ||
C. Clamp section | ||
C. Terminal block cover | ||
D. Strain relief tab pointing down | ||
D. Neutral ground wire | ||
| ||
E. External ground conductor screw |
|