Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying performance.

Vent system chart

NOTE: Side exhaust installations add a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number of

Type of Vent

Box or

Angled

90º turns

 

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

 

0

Rigid metal

37

ft (11.3 m)

35 ft (10.7 m)

 

Flexible metal

25

ft (7.6 m)

20 ft (6.1 m)

 

 

 

 

 

1

Rigid metal

32

ft (9.7 m)

27 ft (8.2 m)

 

Flexible metal

21

ft (6.4 m)

16 ft (4.9 m)

 

 

 

 

 

2

Rigid metal

24

ft (7.3 m)

19 ft (5.8 m)

 

Flexible metal

15

ft (4.6 m)

10 ft (3.0 m)

 

 

 

 

 

Install VentSystem

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

3.Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Level Washer/Dryer

Properly leveling your washer/dryer avoids excessive noise and vibration.

1.Check the levelness of the washer/dryer by placing a level on the top edge of the washer, first side to side, then front to back.

2.If the washer/dryer is not level, prop up the front with the wood block and adjust the feet up or down as necessary. Remove wood block.

3.Tilt the washer/dryer forward until the rear of the washer/dryer is at least 4" (10.2 cm) off the floor. You may hear the self- adjusting rear feet click into place. Lower the washer/dryer to the floor. Check the levelness of the washer/dryer with a level as shown above.

If washer/dryer will not level, recheck rear leveling legs for free movement as described in the “Install Leveling Legs” section. Repeat until the washer/dryer is level.

NOTE: It may be necessary to level the washer/dryer again after it is moved into its final location.

4.After the washer/dryer is in its final location and is level, use an adjustable or open-end wrench to turn the nuts on the front feet tightly against the washer cabinet.

If the nuts are not tight against the washer cabinet, the washer/dryer may vibrate.

ConnectVent

1.Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in washer/dryer. If connecting to existing vent, make sure the vent is clean. The vent must fit over the exhaust outlet and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.

2.Move washer/dryer into its final location. Do not crush or kink vent. Make sure washer/dryer is level.

15

Image 15
Contents 27 69 CM Electric WASHER/DRYER Installation Instructions Parts supplied ToolsandPartsAlternateParts Tools neededLocationRequirements Installation ClearancesMobile Home Additional Installation Requirements Washer/Dryer DimensionsElectricalRequirements-U.S.A DrainSystemIf connecting by direct wire ElectricalRequirements-CanadaIf your outlet looks like this Two clamp sections together Electrical Connection-U.S.A.OnlyWire connection Power supply cord Style 2 Direct wire strain reliefRemove center, silver-colored terminal block screw Wire connection Direct WireBDE CG F Page Vent material VentingRequirementsConnecttheDrainHose Install LevelingLegsInstall the front leveling feet RemoveShippingStrapConnecttheInletHoses SecuretheDrainHose Optional exhaust installationsRecommended exhaust installations Alternate installations for close clearancesLevel Washer/Dryer Install VentSystemSpecial provisions for mobile home installations Vent system chartCompleteInstallation Check that you have all of your toolsIf the dryer will not start, check the following Piezas necesarias para la secadora Herramientas ypiezasPiezas suministradas Herramientas necesariasUsted necesitará Piezas alternativasRequisitos deubicación Espacios para la instalaciónSistema de desagüe en el piso ilustración D SistemadedesagüeRequisitos eléctricos-EE.UU Sistema de desagüe en un lavadero ilustración CSi el contacto de pared luce como éste Conexión eléctricaSi hace la conexión con cableado directo Si emplea un cable de suministro eléctricoConexióneléctrica-SóloenEE.UU Cable de suministro eléctricoInstale el protector de cables Conectar con Estilo 2 Protector de cables para cable directoAlambre de 4 hilos se recomienda Alambre de 3 hilos si no dispone de alambre de 4 hilosConexión de 4 hilos Cable directo Hilo de tierra verde o desnudo del cable de suministro Page Requisitos deventilación Respiradero QuiteelflejedeembalajePara usarse con desagüe por el piso InstalacióndelaspatasniveladorasConectelamangueradedesagüe Instale las patas niveladoras delanterasConecte las mangueras de entrada a la lavadora Conectelas manguerasdeentradaConecte las mangueras de entrada a los grifos de agua Limpie el agua de las líneasInstalaciones opcionales de escape FijacióndelamangueradedesagüePlanificacióndelsistema deventilación Instalaciones típicas de escapeDeterminación de la vía del ducto de escape Instalacióndel sistemadeventilaciónCómonivelarla lavadora/secadora Cuadro del sistema de ventilaciónConexióndel ducto deescape CompletelainstalaciónSi la secadora no funciona, revise lo siguiente Pièces nécessaires pour la sécheuse OutillageetpiècesPièces fournies Outillage requisSi vous avez Vous devrez acheter Exigences demplacementAutres pièces Il vous faudraSystèmedevidange Installation dans une maison mobile autres exigencesDimensions de la laveuse/sécheuse Linstallation dans une maison mobile exigeCest à lutilisateur quincombe la responsabilité de Spécifications électriques-CanadaSystème de vidange avec évier de buanderie illustration C Système de vidange par le plancher illustration DMatériel pour lévacuation Exigences concernantlévacuationLe clapet incliné illustré ici est acceptable Les styles de clapets recommandés sont illustrés ci-dessousEnlever lasangledexpédition ÉvacuationInstallationdespiedsdenivellement RaccordementdutuyaudevidangeRaccordementdes tuyauxd’alimentation Pour un placard ou un endroit exigu ImmobilisationdutuyaudevidangeNettoyer les conduites deau Connecter les tuyaux dalimentation à la laveusePlanificationdusystèmed’évacuation Installations d’évacuation recommandéesInstallations dévacuation facultatives Autres installations où le dégagement est réduitDéterminer litinéraire dacheminement du conduit Installationdu systèmedévacuationNivellementdelalaveuse/sécheuse Tableau des systèmes dévacuationAcheverlinstallation RaccordementduconduitdévacuationSi la sécheuse ne démarre pas, vérifier ce qui suit 2006 Benton Harbor, Michigan 12/06 All rights reserved W10118289A