ELECTRIC DRYER (GDE450AW)
4-Wire Cord Connections (US Models Only)
Green Ground | Green Power Cord | |
Ground Wire | ||
Screw | ||
|
Neutral
Ground Wire
Red
Power Cord | Strain Relief |
| |
| Mounting Bracket |
English
Brass Terminal
Terminal Block
| Black |
| Tighten Nut to |
White | These Threads |
| Nut |
1.Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.
2.Install a UL approved strain relief into the power cord entry hole of the mounting bracket . Finger tighten the nut only at this time.
3.Remove the green neutral ground wire from the green ground screw located above the terminal block.
Typical Conductor |
|
|
|
|
|
Receptacle |
| Black 240V | |||
| |||||
|
| ||||
|
|
|
|
| White Neutral |
|
|
|
|
| |
Typical 4 |
|
|
| Red 240V | |
|
|
| |||
|
|
|
|
| |
Conductor Cord |
| Green Ground |
14