English
1.Only rigid metal duct work should be used.
2.Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction.
3.Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint.
4.Compression of crimping of the exhaust system will cause an increase in vent restriction.
5.In Canada, that only those
6.In Canada, that the exhaust duct shall be 102mm in diameter. In the United States, the required exhaust duct diameter.
7.The total length of flexible metal duct shall not exceed 2.4m.
The exhaust system should be inspected and cleaned a minimum of every 12 months with normal usage. The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation.
RECOMMENDED MAXIMUM
Exhaust Hood Types
Recommended | Use only for short run installations |
No. of 90º | Rigid Metal | Rigid Metal | |||
elbows | |||||
|
|
|
| ||
0 | 90 | ft. | 60 | ft. | |
1 | 60 | ft. | 45 | ft. | |
2 | 45 | ft. | 35 | ft. | |
3 | 35 | ft. | 25 | ft. |
Note: Exhausting refers to removal of moist air from the drying compartment.
8