To change Volume units:

Choosing Volume from the Change Units menu will allow you to set the unit of measure for volume to US Gallons or Liters.

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight UNITS and press MENU. Select VOLUME and press MENU, which will open the Volume menu with two options: US gallons and Liters.

3.Select the desired setting and press MENU, which will take you back to the main page.

Fuel Setup

Fuel Setup allows you to adjust options that will be used to measure fuel economy. The following options can be set or reset from the Fuel Setup menu: Refill Tank (Refill T), Part Fill (Partial Fill), Economy Speed (Eco spd), Fuel Remaining Source (FRem Src), Reset Trip Fuel (Rst trip F), Reset Seasonal Fuel (Rst Seas).

Refill Tank (Refill T)

The Refill Tank command ensures your LMF-200 fuel reading is consistent with the actual amount of fuel in your tank or tanks. Refill Tank must be used with the EP-10 Fuel Flow, EP-50 Storage Device and the Suzuki NMEA 2000 Engine Interface. The Refill Tank command is NOT used when the EP-15 Fluid Level is used to read the fuel level.

To refill tank:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU. Highlight FUEL MNGR and press MENU.

2.Select REFILL T and press MENU. The following message will appear: Hit Menu if Tank filled up.

3.If the tank has been filled, press MENU, which will take you back to the main display.

NOTE:

If an EP-10 Fuel Flow or a Suzuki Engine Interface is being used a, menu will appear giving you the option to calibrate fuel calculations. We will discuss calibration in Section 4: Configuration and Calibration.

Partial Fill (Part Fill)

The Partial Fill command helps maintain the accuracy of fuel economy by allowing you to input the amount of fuel you added to your tank or tanks. The Partial Fill command can be used with the EP-10 Fuel Flow, EP-50 Storage Device and the Suzuki NMEA 2000 Engine Interface.

27

Image 33
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Connecting to a Nmea 2000 Network CompatibilityNetwork Backbone and Network Nodes Adding a Network Node Additional Network Information Understanding this Manual Menu CommandsUp and Down keys Menu keyTo execute Boat Setup Boat SetupTimeout Basic MenuPages Options Viewing Pages Page Screen RotationPages Menu Remove To add a page to the displayTo remove a page from the display AutoscrollTo set a Pop-Up Pop-ups SetupStay Time To set Stay TimeEngine Trim Threshold set up RPM Threshold set upTrim Tabs Threshold set up Pop-up ThresholdsTo adjust Backlight Rudder Threshold set upScreen BacklightTo adjust Contrast Audio SetupContrast Reverse Video Rev VideoSystem Setup Menu Sonar Alarms To set the Shallow AlarmTo set the Deep Alarm To reset Eng/Tank configuration TimeoutReset To reset valuesTo access System Information screen To access the Nmea Information screenNmea Info System InformationSpeed Range To set Engine WarningsTo set Speed Range Pressure RangeTo set Pressure Range UnitsTo change Speed and Distance units To change Pressure units To change Temperature unitsTo change Depth units To change GPS unitsTo change Volume units Fuel SetupRefill Tank Refill T To refill tankEconomy Speed Eco spd To use Partial FillTo change Economy Speed Source Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature ConfigurationTo unconfigure EP-35 temp sensor To reconfigure an EP-35 temp sensorIf all temps configured Configuration name unavailable If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelTo execute Reset command Level WarningTo set a Level Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning Calibrating EP Sensors EP-10 Fuel Flow CalibrationFuel Flow Accuracy To calibrate an EP-10 Fuel Flow Refill TankReset Calibration To execute Reset Calibration commandPartial Fill To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration To Reset Calibration Calibrating Fuel Flow in a Suzuki Engine InterfaceEngine Interface Accuracy To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site