Lowrance electronic LMF-200 manual To calibrate a Suzuki Engine Interface Refill Tank

Page 61

Fill up your tank again, noting how much fuel you added to the tank. Compare that number to the Fuel Used figure displayed on the page you customized. If the amount of fuel you added to the tank and the fuel used figure are off by more than 3 percent, we recommend the engine interface be calibrated.

NOTE:

You must use the gauge's Refill Tank command when filling your fuel tank to keep the engine interface updated with correct information on the amount of fuel in the tank.

Refill Tank

You will use the Refill Tank option each time you calibrate an engine interface and every time you refill your tank, regardless of whether you choose to calibrate.

To calibrate a Suzuki Engine Interface (Refill Tank):

Add the Fuel Manager page or any of the digital gauge pages to the page screen rotation, then customize the selected page to show Fuel Used data. To see instructions on how to Add Pages and Customize Pages, refer to the Operation Section.

1.Fill up the fuel tank connected to the engine interface you want to calibrate. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. The Select Tank menu will open with up to three options: Port, Center and Starboard.

3.Select the tank you refilled and press MENU. The Recalibration (ReCal?) menu will appear with two options: Yes and No. Select NO and press MENU. The following message will appear: Hit Menu if Tank filled up.

4.Press MENU, which will direct you to the main display.

NOTE:

Make sure the Fuel Management page has been added to the main display and that the page has been customized to show USD (Fuel Used). If the Fuel Management page is not displayed or if it is not customized to display USD (Fuel Used), refer to the Add Pages and Customizing Pages segments in the Operation section.

5.Take your boat out, but only use ONE engine — the engine connected to the engine interface. Burn at least 5 gallons of fuel, then fill up the tank again, noting how much fuel was added to the tank. Check the Fuel Management page for the fuel used figure calculated by the Suzuki Engine Interface.

55

Image 61
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Compatibility Connecting to a Nmea 2000 NetworkNetwork Backbone and Network Nodes Adding a Network Node Additional Network Information Understanding this Manual Menu CommandsUp and Down keys Menu keyTo execute Boat Setup Boat SetupBasic Menu TimeoutPages Options Viewing Pages Page Screen RotationPages Menu Remove To add a page to the displayTo remove a page from the display AutoscrollTo set a Pop-Up Pop-ups SetupStay Time To set Stay TimeEngine Trim Threshold set up RPM Threshold set upTrim Tabs Threshold set up Pop-up ThresholdsTo adjust Backlight Rudder Threshold set upScreen BacklightTo adjust Contrast Audio SetupContrast Reverse Video Rev VideoSystem Setup Menu To set the Shallow Alarm Sonar AlarmsTo set the Deep Alarm To reset Eng/Tank configuration TimeoutReset To reset valuesTo access System Information screen To access the Nmea Information screenNmea Info System InformationSpeed Range To set Engine WarningsTo set Speed Range Pressure RangeUnits To set Pressure RangeTo change Speed and Distance units To change Pressure units To change Temperature unitsTo change Depth units To change GPS unitsTo change Volume units Fuel SetupRefill Tank Refill T To refill tankEconomy Speed Eco spd To use Partial FillTo change Economy Speed Source Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature ConfigurationTo reconfigure an EP-35 temp sensor To unconfigure EP-35 temp sensorIf all temps configured Configuration name unavailable If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelLevel Warning To execute Reset commandTo set a Level Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning EP-10 Fuel Flow Calibration Calibrating EP SensorsFuel Flow Accuracy To calibrate an EP-10 Fuel Flow Refill TankTo execute Reset Calibration command Reset CalibrationPartial Fill To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration Calibrating Fuel Flow in a Suzuki Engine Interface To Reset CalibrationEngine Interface Accuracy To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site