Lowrance electronic LMF-200 manual Customizing Pages

Page 35

To change Fuel Remaining Source:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU. Select FUEL MNGR and press MENU.

2.Highlight FREM SRC and press MENU. That will open the FRem Src menu, which has two options: Eng/FFlow and Fuel level.

3.Select the desired fuel remaining source and press MENU, which will take you back to the main display.

Reset Trip Fuel (Rst trip f)

A few sensors, like the Suzuki Engine Interface, EP-10 Fuel Flow and EP-50 Storage Device keep a running total of fuel used for a trip. By using the Reset Trip command, you can reset to zero the running total of fuel used on a trip.

To Reset Trip Fuel (Rst trip f)

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU. Highlight FUEL MNGR and press MENU.

2.Select RST TRIP F (Reset Trip Fuel) and press MENU. The following message will appear: Hit Menu to Rst Trip F.

3.Press MENU, which will reset the trip fuel used to zero and take you back to the main display.

Reset Seasonal Fuel (Rst Seas)

A few sensors, like the Suzuki Engine Interface, EP-10 Fuel Flow and EP-50 Storage Device keep a running total of fuel used for a season. By using the Reset Seasonal command, you can reset to zero the running total of fuel used for a season.

To reset seasonal fuel:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU. Highlight FUEL MNGR and press MENU.

2.Choose RST SEAS and press MENU. If you have more than one engine, the Select Engine menu will appear with up to four options: All Engines, Port, Cen (Center) and Stbd (Starboard).

3.Select the desired option and press MENU. The following message will appear: Hit Menu to Rst USD:S.

3.Press MENU, which will take you back to the main display.

Customizing Pages

The customizing pages feature allows you to choose what data will be displayed and how it will be displayed on select pages. Pages that can be customized include: Single Digital, Dual Digital, Gauge, Fuel Manager and Trim Tab pages can all be customized. The Engine Trim, Engine Diagnostic, GPS Position and Synchronize pages cannot be customized.

29

Image 35
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkCompatibility Adding a Network Node Additional Network Information Menu key Menu CommandsUnderstanding this Manual Up and Down keysTo execute Boat Setup Boat SetupPages TimeoutBasic Menu Options Viewing Pages Page Screen RotationPages Menu Autoscroll To add a page to the displayRemove To remove a page from the displayTo set Stay Time Pop-ups SetupTo set a Pop-Up Stay TimePop-up Thresholds RPM Threshold set upEngine Trim Threshold set up Trim Tabs Threshold set upBacklight Rudder Threshold set upTo adjust Backlight ScreenReverse Video Rev Video Audio SetupTo adjust Contrast ContrastSystem Setup Menu To set the Deep Alarm Sonar AlarmsTo set the Shallow Alarm To reset values TimeoutTo reset Eng/Tank configuration ResetSystem Information To access the Nmea Information screenTo access System Information screen Nmea InfoPressure Range To set Engine WarningsSpeed Range To set Speed RangeTo change Speed and Distance units To set Pressure RangeUnits To change GPS units To change Temperature unitsTo change Pressure units To change Depth unitsTo refill tank Fuel SetupTo change Volume units Refill Tank Refill TFuel Remaining Source FRem Src To use Partial FillEconomy Speed Eco spd To change Economy Speed SourceCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature ConfigurationIf all temps configured Configuration name unavailable To unconfigure EP-35 temp sensorTo reconfigure an EP-35 temp sensor If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelTo set a Level Warning To execute Reset commandLevel Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning Fuel Flow Accuracy Calibrating EP SensorsEP-10 Fuel Flow Calibration To calibrate an EP-10 Fuel Flow Refill TankPartial Fill Reset CalibrationTo execute Reset Calibration command To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration Engine Interface Accuracy To Reset CalibrationCalibrating Fuel Flow in a Suzuki Engine Interface To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site