Lowrance electronic LMF-200 manual To execute Reset Calibration command, Partial Fill

Page 56

NOTE:

If the difference between the LMF-200 fuel used figure and the amount of fuel you actually added to the tank is less than 3 percent the EP-10 Fuel Flow does not need to be calibrated.

7.To recalibrate the unit, fill up the fuel tank connected to the fuel flow you want to calibrate.

8.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

9.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. The Select Tank menu will open with three options: Port, Cen (Center) and Stbd (Starboard). Select the tank you refilled and press MENU.

10.The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select YES and press MENU.

11.The Filled Quantity window will appear. Use the UP and DOWN keys to input the amount of fuel you added to the tank and press MENU.

14.Repeat these steps for each fuel flow you want to calibrate.

NOTE:

It is a good idea to check the calibration of a fuel flow periodically.

Reset Calibration

The Reset Calibration command allows you to reset a fuel flow back to factory default settings.

To execute Reset Calibration command:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. Select the fuel flow you want to reset and press MENU.

3.Select RST CAL from the fuel flow menu and press MENU. The following message will appear: Hit Menu to Rst the Cal.

4.Press MENU to set calibration back to factory default settings. To recalibrate the fuel flow, follow the steps in the previous segment regarding fuel flow calibration.

Partial Fill

You will use the Partial Fill option each time you add fuel but do not fill up the tank.

To use Partial Fill:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight FUEL MNGR and press MENU. Select PART FILL. and press MENU. The Select Tank menu will open with three options: Port, Cen

50

Image 56
Contents LMF-200 Copyright 2006 Lowrance Electronics, Inc All rights reserved Visit our web siteTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Preparation Recommended Tools and SuppliesInstallation Sequence Mounting the GaugeWiring LMF-200 cable connections Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkCompatibility Adding a Network Node Additional Network Information Menu Commands Understanding this ManualUp and Down keys Menu keyBoat Setup To execute Boat SetupPages TimeoutBasic Menu Viewing Pages Page Screen Rotation OptionsPages Menu To add a page to the display RemoveTo remove a page from the display AutoscrollPop-ups Setup To set a Pop-UpStay Time To set Stay TimeRPM Threshold set up Engine Trim Threshold set upTrim Tabs Threshold set up Pop-up ThresholdsRudder Threshold set up To adjust BacklightScreen BacklightAudio Setup To adjust ContrastContrast Reverse Video Rev VideoSystem Setup Menu To set the Deep Alarm Sonar AlarmsTo set the Shallow Alarm Timeout To reset Eng/Tank configurationReset To reset valuesTo access the Nmea Information screen To access System Information screenNmea Info System InformationTo set Engine Warnings Speed RangeTo set Speed Range Pressure RangeTo change Speed and Distance units To set Pressure RangeUnits To change Temperature units To change Pressure unitsTo change Depth units To change GPS unitsFuel Setup To change Volume unitsRefill Tank Refill T To refill tankTo use Partial Fill Economy Speed Eco spdTo change Economy Speed Source Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To customize the Dual Digital To Customize the GaugeTo Customize the Fuel Manager To Customize Trim TabsEP-35 Temperature Configuration To configure EP-35 Temp SensorIf all temps configured Configuration name unavailable To unconfigure EP-35 temp sensorTo reconfigure an EP-35 temp sensor EP-10 Fuel Flow Configuration If desired configuration name availableTo configure Fuel Flow To unconfigure an EP-10 Fuel FlowTo reconfigure an EP-10 Fuel Flow If all fuel flows configured Configuration name unavailableIf configuration name available EP-15 Fluid Level Configuration Fluid Level menuTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To unconfigure EP-15 Fluid Level To reconfigure EP-15 Fluid LevelTo set a Level Warning To execute Reset commandLevel Warning Suzuki Engine Interface Configuration To configure Suzuki Engine InterfaceTo unconfigure a Suzuki Engine Interface To reconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning Fuel Flow Accuracy Calibrating EP SensorsEP-10 Fuel Flow Calibration Refill Tank To calibrate an EP-10 Fuel FlowPartial Fill Reset CalibrationTo execute Reset Calibration command EP-15 Fluid Level Calibration To execute 2-Point calibrationPoint Calibration To execute 3-Point calibrationTo execute 5-Point calibration Engine Interface Accuracy To Reset CalibrationCalibrating Fuel Flow in a Suzuki Engine Interface To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… Not toll-freeAccessory Ordering Information for all countries Visit our web site