Lowrance electronic LMF-200 manual To configure EP-15 Fluid Level for Oil

Page 47

2.Select the desired unconfigured fluid level (Unfcg FL) from the Bus Devices list and press MENU, which will launch the following message: Hit Menu to Cfg FLev Sns.

3.Press MENU, select WASTE W from the list of fluid types and press MENU. The Tank Number window will appear.

4.Assign a tank number (1, 2 or 3) to the tank using the fluid level you are configuring and press MENU. That will launch the Tank Size window.

5.Input the capacity of the tank (gallons) and press MENU. You will be directed to the Bus Devices list, where the fluid level you configured will be displayed as WtW Tnk1, WtW Tnk2 or WtW Tnk3, depending on the tank number you assigned it.

To configure EP-15 Fluid Level for Oil:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select the desired unconfigured fluid level (Unfcg FL) from the Bus Devices list and press MENU, which will launch the following message: Hit Menu to Cfg FLev Sns.

3.Press MENU, select OIL from the list of fluid types and press MENU. That will launch the Tank Size window.

4.Input the capacity of the tank (gallons) and press MENU. You will be directed to the Bus Devices list, where the fluid level you configured will be displayed as O. Tnk (P), O. Tnk(C) or O Tnk (S), depending the tank location you chose.

To configure EP-15 Fluid Level for Black Water:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select the desired unconfigured fluid level (Unfcg FL) from the Bus Devices list and press MENU, which will launch the following message: Hit Menu to Cfg FLev Sns.

3.Press MENU, select BLACK W from the list of fluid types and press MENU. The Tank Number window will appear.

4.Assign a tank number (1, 2 or 3) to the tank using the fluid level you are configuring and press MENU. That will launch the Tank Size window.

5.Input the capacity of the tank (gallons) and press MENU. You will be directed to the Bus Devices list, where the fluid level you configured will be displayed BlkW Tnk1, BlkW Tnk2 or BlkW Tnk3, depending on the tank number you assigned it.

41

Image 47
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkCompatibility Adding a Network Node Additional Network Information Menu key Menu CommandsUnderstanding this Manual Up and Down keysTo execute Boat Setup Boat SetupPages TimeoutBasic Menu Options Viewing Pages Page Screen RotationPages Menu Autoscroll To add a page to the displayRemove To remove a page from the displayTo set Stay Time Pop-ups SetupTo set a Pop-Up Stay TimePop-up Thresholds RPM Threshold set upEngine Trim Threshold set up Trim Tabs Threshold set upBacklight Rudder Threshold set upTo adjust Backlight ScreenReverse Video Rev Video Audio SetupTo adjust Contrast ContrastSystem Setup Menu To set the Deep Alarm Sonar AlarmsTo set the Shallow Alarm To reset values TimeoutTo reset Eng/Tank configuration ResetSystem Information To access the Nmea Information screenTo access System Information screen Nmea InfoPressure Range To set Engine WarningsSpeed Range To set Speed RangeTo change Speed and Distance units To set Pressure RangeUnits To change GPS units To change Temperature unitsTo change Pressure units To change Depth unitsTo refill tank Fuel SetupTo change Volume units Refill Tank Refill TFuel Remaining Source FRem Src To use Partial FillEconomy Speed Eco spd To change Economy Speed SourceCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature ConfigurationIf all temps configured Configuration name unavailable To unconfigure EP-35 temp sensorTo reconfigure an EP-35 temp sensor If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelTo set a Level Warning To execute Reset commandLevel Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning Fuel Flow Accuracy Calibrating EP SensorsEP-10 Fuel Flow Calibration To calibrate an EP-10 Fuel Flow Refill TankPartial Fill Reset CalibrationTo execute Reset Calibration command To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration Engine Interface Accuracy To Reset CalibrationCalibrating Fuel Flow in a Suzuki Engine Interface To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site