Level Warning:

A Level Warning alerts you when the fluid level rises above or falls below a preset percentage of tank capacity. The Level Warning menu has two options: Low Level and High Level. A low level warning is used for fluid types like fuel, oil and freshwater, whereas a high level warning is best suited for black water and Waste Water (Gray Water).

To set a Level Warning:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select a configured fluid level and press MENU, which will open the Configuration Options menu. Highlight LEV WRNG and press MENU.

3.The Select Level menu will appear with two options: Low Level and High Level.

NOTE:

If you configure a tank for fuel, you should choose a LOW LEVEL warning, which will warn you when the fuel level drops below a preset percentage of the tank's capacity. A Low Level alarm will also work best for Fresh Water and Oil configurations. When a tank is configured for Black Water or Waste Water, the Level Warning should be set to the High Level. If, for example, you set the High Level warning to 3 Quarters of a tank (75 percent), you would be alerted before the tank's capacity had been exceeded, allowing you to empty the tank before it fills up.

4.Highlight the desired level and press MENU. The Level Percentage dialog box will appear. It will be set to Off by default.

5.Use the UP and DOWN keys to set the level warning to a desired percentage of tank capacity and press MENU. You will be taken back to the Bus Devices list.

Reset

The Reset command will reset all values for a device, including configuration and calibration settings.

To execute Reset command:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select a configured fluid level and press MENU, which will open the Configuration Options menu.

3.Highlight RESET and press MENU. The following message will appear: Hit Menu to Rst Values.

43

Image 49
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Compatibility Connecting to a Nmea 2000 NetworkNetwork Backbone and Network Nodes Adding a Network Node Additional Network Information Understanding this Manual Menu CommandsUp and Down keys Menu keyTo execute Boat Setup Boat SetupBasic Menu TimeoutPages Options Viewing Pages Page Screen RotationPages Menu Remove To add a page to the displayTo remove a page from the display AutoscrollTo set a Pop-Up Pop-ups SetupStay Time To set Stay TimeEngine Trim Threshold set up RPM Threshold set upTrim Tabs Threshold set up Pop-up ThresholdsTo adjust Backlight Rudder Threshold set upScreen BacklightTo adjust Contrast Audio SetupContrast Reverse Video Rev VideoSystem Setup Menu To set the Shallow Alarm Sonar AlarmsTo set the Deep Alarm To reset Eng/Tank configuration TimeoutReset To reset valuesTo access System Information screen To access the Nmea Information screenNmea Info System InformationSpeed Range To set Engine WarningsTo set Speed Range Pressure RangeUnits To set Pressure RangeTo change Speed and Distance units To change Pressure units To change Temperature unitsTo change Depth units To change GPS unitsTo change Volume units Fuel SetupRefill Tank Refill T To refill tankEconomy Speed Eco spd To use Partial FillTo change Economy Speed Source Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature ConfigurationTo reconfigure an EP-35 temp sensor To unconfigure EP-35 temp sensorIf all temps configured Configuration name unavailable If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelLevel Warning To execute Reset commandTo set a Level Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning EP-10 Fuel Flow Calibration Calibrating EP SensorsFuel Flow Accuracy To calibrate an EP-10 Fuel Flow Refill TankTo execute Reset Calibration command Reset CalibrationPartial Fill To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration Calibrating Fuel Flow in a Suzuki Engine Interface To Reset CalibrationEngine Interface Accuracy To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site