Lowrance electronic LMF-200 manual To reconfigure an EP-10 Fuel Flow

Page 43

4.Highlight UNSET ENGINE and press MENU which will launch the following message: Hit Menu to Unset Dev Name.

5.Press MENU and you will be taken back to the Bus Devices list.

To reconfigure an EP-10 Fuel Flow:

You will use the Change Engine command to reconfigure a Fuel Flow. Change Engine, however, will only appear on your LMF-200 menu if you have more than one engine. If all the fuel flows on your vessel are configured, you will have to unconfigure a fuel flow to free up its configuration name (Port, Cen, Stbd).

If all three fuel flows are configured, which means there is no name configuration available, follow the first set of instructions. If the desired configuration name is available, follow the second set of instructions.

Change Engine (Active only with multiple-engine setting)

The steps below show how to switch the configuration name of a fuel flow from the Port engine to the Starboard engine.

If all fuel flows configured (Configuration name unavailable):

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. The Bus Devices list will appear.

3.Select the Port FFlow and press MENU.

4.Highlight UNSET ENGINE and press MENU. The following message will appear: Hit Menu to Unset Dev Name.

5.Press MENU and you will be taken back to the Bus Devices menu, where fuel flow (formerly Port FFlow) now will be displayed as UnCfg FFlow. Remember: If the fuel flow you just unconfigured is not shown on the Bus Devices the list, you will have to refresh the list. Let the Bus Devices list time out then access it again.

6.Highlight STBD FFLOW and press MENU. Select CHANGE ENGINE and press MENU, which will open the Select Engine menu with up to three options: Port, Cen, Stbd.

7.Highlight PORT and and press MENU.

8.You will be taken back to the Bus Devices list, where the fuel flow you selected (formerly Stbd FFlow) will now be shown as Port FFlow. If the newly configured fuel flow is not shown, refresh the Bus Devices list.

9.Now, select UNCFG FFLOW and press MENU. The following message will appear: Hit Menu to Cfg Flow Sns.

10.Press MENU, which will open the Select Engine menu. Highlight

37

Image 43
Contents LMF-200 Visit our web site Copyright 2006 Lowrance Electronics, Inc All rights reservedTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Recommended Tools and Supplies PreparationMounting the Gauge Installation SequenceWiring LMF-200 cable connections Compatibility Connecting to a Nmea 2000 NetworkNetwork Backbone and Network Nodes Adding a Network Node Additional Network Information Menu key Menu CommandsUnderstanding this Manual Up and Down keysTo execute Boat Setup Boat SetupBasic Menu TimeoutPages Options Viewing Pages Page Screen RotationPages Menu Autoscroll To add a page to the displayRemove To remove a page from the displayTo set Stay Time Pop-ups SetupTo set a Pop-Up Stay TimePop-up Thresholds RPM Threshold set upEngine Trim Threshold set up Trim Tabs Threshold set upBacklight Rudder Threshold set upTo adjust Backlight ScreenReverse Video Rev Video Audio SetupTo adjust Contrast ContrastSystem Setup Menu To set the Shallow Alarm Sonar AlarmsTo set the Deep Alarm To reset values TimeoutTo reset Eng/Tank configuration ResetSystem Information To access the Nmea Information screenTo access System Information screen Nmea InfoPressure Range To set Engine WarningsSpeed Range To set Speed RangeUnits To set Pressure RangeTo change Speed and Distance units To change GPS units To change Temperature unitsTo change Pressure units To change Depth unitsTo refill tank Fuel SetupTo change Volume units Refill Tank Refill TFuel Remaining Source FRem Src To use Partial FillEconomy Speed Eco spd To change Economy Speed SourceCustomizing Pages To customize the Single Digital To Customize the Gauge To customize the Dual DigitalTo Customize Trim Tabs To Customize the Fuel ManagerTo configure EP-35 Temp Sensor EP-35 Temperature Configuration To reconfigure an EP-35 temp sensor To unconfigure EP-35 temp sensor If all temps configured Configuration name unavailable If desired configuration name available EP-10 Fuel Flow ConfigurationTo unconfigure an EP-10 Fuel Flow To configure Fuel FlowIf all fuel flows configured Configuration name unavailable To reconfigure an EP-10 Fuel FlowIf configuration name available Fluid Level menu EP-15 Fluid Level ConfigurationTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To reconfigure EP-15 Fluid Level To unconfigure EP-15 Fluid LevelLevel Warning To execute Reset commandTo set a Level Warning To configure Suzuki Engine Interface Suzuki Engine Interface ConfigurationTo reconfigure a Suzuki Engine Interface To unconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning EP-10 Fuel Flow Calibration Calibrating EP SensorsFuel Flow Accuracy To calibrate an EP-10 Fuel Flow Refill TankTo execute Reset Calibration command Reset CalibrationPartial Fill To execute 2-Point calibration EP-15 Fluid Level CalibrationTo execute 3-Point calibration Point CalibrationTo execute 5-Point calibration Calibrating Fuel Flow in a Suzuki Engine Interface To Reset CalibrationEngine Interface Accuracy To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty Not toll-free How to Obtain Service…Accessory Ordering Information for all countries Visit our web site