Lowrance electronic LMF-200 manual Point Calibration, To execute 3-Point calibration

Page 58

3-Point Calibration:

3-point calibration is designed for tanks that vary in shape from the top to the bottom. You can begin calibration at any point in the 3-point process, but we recommend starting calibration with an empty tank. In a 3-point calibration, you will set three points, one each for empty, half and full levels.

NOTE:

You DO NOT have to calibrate all three points to complete the calibration and you can calibrate the points (Empty Level, Half Level and Full Level) in any order you wish. Remember: Points that are not calibrated will not be as accurate as points that have been calibrated. For the greatest accuracy, we recommend all three points be calibrated.

To execute 3-Point calibration:

1.Press MENU, select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU, which will open the Bus Devices list.

3.Highlight the fluid level sensor you want to calibrate and press MENU, then select CAL (Calibrate) and press MENU. The Points menu will appear with three options: 2, 3 and 5.

4.Select 3 and press MENU. The Points menu will appear with three options: Empty Lev, Half Lev and Full Lev.

5.Highlight EMPTY LEV and press MENU. The following message will appear: Tnk to Empty lev hit Menu. Press Menu and fill your tank up halfway. If you have a 100 gallon tank, add 50 gallons.

6.Repeat steps 1-4, then select HALF LEV from the Points menu and press MENU. The following message will appear: Tnk to Half lev hit Menu. Press MENU and fill up the tank.

7.Repeat steps 1-4 to access the Points menu, then highlight FULL LEV and press MENU. The following message will appear: Tnk to Full lev hit Menu.

8.Press MENU and let the menus time out, which will take you to the main display.

5-point Calibration

5-point calibration is best suited tanks that vary greatly in shape from top to bottom. You can begin calibration at any point in the 5-point calibration process. We recommend starting calibration with an empty tank. In a five-point calibration you will set five points: Empty Level, 1 Qtr Level, Half Level, 3 Qtr Level and Full Level.

52

Image 58
Contents LMF-200 Copyright 2006 Lowrance Electronics, Inc All rights reserved Visit our web siteTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Preparation Recommended Tools and SuppliesInstallation Sequence Mounting the GaugeWiring LMF-200 cable connections Compatibility Connecting to a Nmea 2000 NetworkNetwork Backbone and Network Nodes Adding a Network Node Additional Network Information Up and Down keys Menu CommandsUnderstanding this Manual Menu keyBoat Setup To execute Boat SetupBasic Menu TimeoutPages Viewing Pages Page Screen Rotation OptionsPages Menu To remove a page from the display To add a page to the displayRemove AutoscrollStay Time Pop-ups SetupTo set a Pop-Up To set Stay TimeTrim Tabs Threshold set up RPM Threshold set upEngine Trim Threshold set up Pop-up ThresholdsScreen Rudder Threshold set upTo adjust Backlight BacklightContrast Audio SetupTo adjust Contrast Reverse Video Rev VideoSystem Setup Menu To set the Shallow Alarm Sonar AlarmsTo set the Deep Alarm Reset TimeoutTo reset Eng/Tank configuration To reset valuesNmea Info To access the Nmea Information screenTo access System Information screen System InformationTo set Speed Range To set Engine WarningsSpeed Range Pressure RangeUnits To set Pressure RangeTo change Speed and Distance units To change Depth units To change Temperature unitsTo change Pressure units To change GPS unitsRefill Tank Refill T Fuel SetupTo change Volume units To refill tankTo change Economy Speed Source To use Partial FillEconomy Speed Eco spd Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To customize the Dual Digital To Customize the GaugeTo Customize the Fuel Manager To Customize Trim TabsEP-35 Temperature Configuration To configure EP-35 Temp SensorTo reconfigure an EP-35 temp sensor To unconfigure EP-35 temp sensorIf all temps configured Configuration name unavailable EP-10 Fuel Flow Configuration If desired configuration name availableTo configure Fuel Flow To unconfigure an EP-10 Fuel FlowTo reconfigure an EP-10 Fuel Flow If all fuel flows configured Configuration name unavailableIf configuration name available EP-15 Fluid Level Configuration Fluid Level menuTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To unconfigure EP-15 Fluid Level To reconfigure EP-15 Fluid LevelLevel Warning To execute Reset commandTo set a Level Warning Suzuki Engine Interface Configuration To configure Suzuki Engine InterfaceTo unconfigure a Suzuki Engine Interface To reconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning EP-10 Fuel Flow Calibration Calibrating EP SensorsFuel Flow Accuracy Refill Tank To calibrate an EP-10 Fuel FlowTo execute Reset Calibration command Reset CalibrationPartial Fill EP-15 Fluid Level Calibration To execute 2-Point calibrationPoint Calibration To execute 3-Point calibrationTo execute 5-Point calibration Calibrating Fuel Flow in a Suzuki Engine Interface To Reset CalibrationEngine Interface Accuracy To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… Not toll-freeAccessory Ordering Information for all countries Visit our web site