3-Point Calibration:
NOTE:
You DO NOT have to calibrate all three points to complete the calibration and you can calibrate the points (Empty Level, Half Level and Full Level) in any order you wish. Remember: Points that are not calibrated will not be as accurate as points that have been calibrated. For the greatest accuracy, we recommend all three points be calibrated.
To execute 3-Point calibration:
1.Press MENU, select SYSTEM SETUP and press MENU.
2.Highlight B. DEVICES and press MENU, which will open the Bus Devices list.
3.Highlight the fluid level sensor you want to calibrate and press MENU, then select CAL (Calibrate) and press MENU. The Points menu will appear with three options: 2, 3 and 5.
4.Select 3 and press MENU. The Points menu will appear with three options: Empty Lev, Half Lev and Full Lev.
5.Highlight EMPTY LEV and press MENU. The following message will appear: Tnk to Empty lev hit Menu. Press Menu and fill your tank up halfway. If you have a 100 gallon tank, add 50 gallons.
6.Repeat steps
7.Repeat steps
8.Press MENU and let the menus time out, which will take you to the main display.