Lowrance electronic LMF-200 manual Reset Calibration

Page 62

6.Compare the amount of fuel you added when you filled up the tank with to the Fuel Used figure in the LMF-200. If the difference between these two numbers is greater than 3 percent, you need to recalibrate the unit.

7.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

8.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. The Select Tank menu will open with three options: Port, Center and Starboard. Select the tank you refilled and press MENU.

9.The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select YES and press MENU.

10.The Filled Quantity window will appear. Use the UP and DOWN keys to input the amount of fuel you added to the tank and press MENU.

11.Repeat these steps for each engine interface you want to calibrate.

NOTE:

The LMF-400 will not let you input an amount of fuel greater than the fuel used figure.

Reset Calibration

The Reset Calibration command allows you to reset engine interface calibration back to default settings.

To Reset Calibration:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. Select the engine interface you want to reset and press MENU.

3.Select RST CAL from the engine interface menu and press MENU. The following message will appear: Hit Menu to Rst the Cal.

4.Press MENU to set calibration back to factory default settings. To recalibrate the interface, follow the steps in the previous segment regarding engine interface calibration.

Partial Fill

You will use the Partial Fill option each time you add fuel but do not fill up the tank.

To use Partial Fill:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight FUEL MNGR and press MENU. Select PART FILL. and press MENU. The Select Tank menu will open with three options: Port, Center and Starboard. Select the tank you refilled and press MENU. The Fuel Quantity window will appear.

56

Image 62
Contents LMF-200 Copyright 2006 Lowrance Electronics, Inc All rights reserved Visit our web siteTable of Contents Backlight Sync BL Sync Iii Page Introduction Page Preparation Recommended Tools and SuppliesInstallation Sequence Mounting the GaugeWiring LMF-200 cable connections Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkCompatibility Adding a Network Node Additional Network Information Up and Down keys Menu CommandsUnderstanding this Manual Menu keyBoat Setup To execute Boat SetupPages TimeoutBasic Menu Viewing Pages Page Screen Rotation OptionsPages Menu To remove a page from the display To add a page to the displayRemove AutoscrollStay Time Pop-ups SetupTo set a Pop-Up To set Stay TimeTrim Tabs Threshold set up RPM Threshold set upEngine Trim Threshold set up Pop-up ThresholdsScreen Rudder Threshold set upTo adjust Backlight BacklightContrast Audio SetupTo adjust Contrast Reverse Video Rev VideoSystem Setup Menu To set the Deep Alarm Sonar AlarmsTo set the Shallow Alarm Reset TimeoutTo reset Eng/Tank configuration To reset valuesNmea Info To access the Nmea Information screenTo access System Information screen System InformationTo set Speed Range To set Engine WarningsSpeed Range Pressure RangeTo change Speed and Distance units To set Pressure RangeUnits To change Depth units To change Temperature unitsTo change Pressure units To change GPS unitsRefill Tank Refill T Fuel SetupTo change Volume units To refill tankTo change Economy Speed Source To use Partial FillEconomy Speed Eco spd Fuel Remaining Source FRem SrcCustomizing Pages To customize the Single Digital To customize the Dual Digital To Customize the GaugeTo Customize the Fuel Manager To Customize Trim TabsEP-35 Temperature Configuration To configure EP-35 Temp SensorIf all temps configured Configuration name unavailable To unconfigure EP-35 temp sensorTo reconfigure an EP-35 temp sensor EP-10 Fuel Flow Configuration If desired configuration name availableTo configure Fuel Flow To unconfigure an EP-10 Fuel FlowTo reconfigure an EP-10 Fuel Flow If all fuel flows configured Configuration name unavailableIf configuration name available EP-15 Fluid Level Configuration Fluid Level menuTo configure EP-15 Fluid Level for Fuel To configure EP-15 Fluid Level for Oil To unconfigure EP-15 Fluid Level To reconfigure EP-15 Fluid LevelTo set a Level Warning To execute Reset commandLevel Warning Suzuki Engine Interface Configuration To configure Suzuki Engine InterfaceTo unconfigure a Suzuki Engine Interface To reconfigure a Suzuki Engine InterfaceIf all interfaces configured Configuration name unavailable Fuel Warning Fuel Flow Accuracy Calibrating EP SensorsEP-10 Fuel Flow Calibration Refill Tank To calibrate an EP-10 Fuel FlowPartial Fill Reset CalibrationTo execute Reset Calibration command EP-15 Fluid Level Calibration To execute 2-Point calibrationPoint Calibration To execute 3-Point calibrationTo execute 5-Point calibration Engine Interface Accuracy To Reset CalibrationCalibrating Fuel Flow in a Suzuki Engine Interface To calibrate a Suzuki Engine Interface Refill Tank Reset Calibration Calibrating EP-30 Trim Tabs Page Page Page Appendix Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… Not toll-freeAccessory Ordering Information for all countries Visit our web site