ITT SSV Pump Number Maximum Stages Inlet Pressure, Series At 250º F PSI / Bar, Pump Size, Phase

Page 6

2. Maximum Inlet Pressure

The following table shows the maximum permissible inlet pressure. However, the actual inlet pressure + pressure against a closed valve must always be lower than the maximum permissible operating pressure.

Pump

Number

Maximum

of Stages

Inlet Pressure

 

1SV

2-16 Stages

250 psi (17 bar)

17-22 Stages

250 psi (17 bar)

 

 

 

 

2SV

2-15 Stages

250 psi (17 bar)

 

 

16-22 Stages

250 psi (17 bar)

 

3SV

2-13 Stages

250 psi (17 bar)

 

 

14-16 Stages

250 psi (17 bar)

 

 

 

 

4SV

2-10 Stages

250 psi (17 bar)

11-12 Stages

250 psi (17 bar)

 

 

 

 

33SV

1-10 Stages

 

 

 

 

46SV

1-10 Stages

250 psi (17 bar)

66SV

1-6 Stages

 

 

 

 

92SV

1-6 Stages

 

 

 

 

3. Maximum Operating Pressure

(staging at 3500 rpm)

Series

At 250º F

PSI / Bar

 

 

 

1SV

2-16 Stages

325 / 25

 

 

17-22 Stages

580 / 40

 

2SV

2-15 Stages

325 / 25

 

 

16-22 Stages

580 / 40

 

 

 

 

3SV

2-13 Stages

325 / 25

14-16 Stages

580 / 40

 

 

 

 

4SV

2-10 Stages

325 / 25

 

 

11-12 Stages

580 / 40

 

33SV

1-6 Stages

362 / 25

 

 

7-10 Stages

580 / 40

 

 

 

 

46SV

1-5 Stages

362 / 25

6-10 Stages

580 / 40

 

 

 

 

66SV

1-5 Stages

362 / 25

 

 

6 Stages

580 / 40

 

92SV

1-5 Stages

362 / 25

 

 

 

NOTE: Oval flange (1-3SV) maximum working pressure is 232 psi (16 bar).

4. Temperature Capability

The SSV pump is capable of pumping liquids within the below temperature range:

1-4SV

-22º F to 250º F (-30º C to 120º C)

33SV-92SV

-22º F to 250º F (-30º C to 120º C)

NOTE: In order to provide adequate cooling for the electric motor, the ambient temperature must be 32º F to 104º F and the relative humidity at 104º F must not exceed 50%.

For temperatures above 104º F and for installations sites located at elevation in excess at 3000 feet above sea level it may be necessary to derate the motor performance. Please contact your distributor/dealer for assistance.

5. Minimum Nominal Flow Rate

To prevent overheating of the internal pump com- ponents, make sure that a minimum water flow is always guaranteed when the pump is running.

For continuous operation the minimum flow rate recommended is specified below.

Pump Size

1SV

2SV

3SV

4SV

Min. Flow

3500 RPM

3

6

12

17

(gpm)

2900 RPM

3

6

10

14

 

 

 

 

 

 

Pump Size

33SV

46SV

66SV

92SV

Min. Flow

3500 RPM

35

40

70

100

(gpm)

2900 RPM

8

10

14

20

NOTE: If this cannot be archived, then a bypass/ recirculate line is recommended.

 

Do not run the pump against a closed

WARNING

 

discharge for longer than a few seconds.

 

6. Number of Starts Per Hour

For electric pumps coupled to motors supplied by Goulds Pumps, the maximum number of work cycles (starts and stops) in one hour are as follows:

HP

3/4-3

5-10

15-20

25-75

# of Starts

5

5

5

5

For more details, refer to technical manual.

 

If you use a different motor from

WARNING

 

the standard one supplied by Goulds

 

Pumps, please consult with the motor manufacturer to find out the maximum number of work cycles allowed.

7. Power Supply Requirements

WARNING Make sure that the supply voltages and frequencies are suited to the

characteristics of the electric motor. Check the motor rating plate.

In general, the supply voltage tolerances for motor operation are as follows:

 

Hz

Phase

 

UN

 

V

 

±%

 

 

 

 

 

60

1

230

 

10

 

60

3

230 / 460

 

10

 

60

3

460

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Transportation and Handling of Packed Product

The SSV pump is packed in cartons or wooden crates having different dimensions and shapes.

 

Some cartons (the supporting base

WARNING

 

is made of wood) are designed to be

 

transported and handled in the vertical position. Other cartons, as well as the wooden crates, are designed to be transported and handled in the hori- zontal position. Protect the product against humid- ity, heat sources and mechanical damage (collisions, falls, ...). Do not place heavy weights on the cartons.

Image 6
Contents ITT Subject Driver SV a 1 D 2 B 0 HNumber of Stages Hertz/RPMExample Product Code Maintain ALL Safety Decals Read this manual before installing and using the productMinimum Inlet Suction Pressure Series At 250º F PSI / Bar PhasePump Number Maximum Stages Inlet Pressure Pump SizeInches mm Anchoring3SV Site SelectionPiping Shim203 Wiring and Grounding Priming/VentingVoltage HazardousMachinery Motor LubricationUpper plate, as required Code Rotary StationaryPage Motor not Running SymptomPower Consumption TOO High Excessive Noise and VibrationCoupling Torque ValuesMotor Motor Bolt 4SV 33-92SVPage Less Piston With Piston Series 5SV and 6SV Flow Direction and Motor RotationSize Stage Motor Rotation 3SV and 4SVIM018R07 March Modèle SSV Série G&L Sujet Series Série SeriesExemple DE Code DE Produit Carcasse de moteur = abritée = fermée autoventilée Choix de pompesCode et choix de dispositifs d’étanchéité = antidéflagranteConsignes DE Sécurité Pression D’ASPIRATION MinimaleDébit min 500 r/min Pompe Étages MPa Bars, lbf/po²Pompe 900 r/min Pompe 33SV 46SV 66SV 92SV Débit min 500 r/minMm po Réglage DE LA Position DE Larbre DE Pompe TuyauterieNON Oblique EN Haut CaleDonnées Techniques Raccordement À LA TuyauterieCâblage ET Mise À LA Terre Machinerie Lubrification DU MoteurCode Élément Élasto UsageCode ET Choix DE Dispositifs Détanchéité CodePage Vibration ET Bruit Excessifs AnomalieTure Mécanique Cause ProbableAccouplement Couple DE SerrageMoteur Adaptateur 1SV à 4SV 33SV à 92SVGarniture mécanique Tirants d’assemblage Joint toriqueTubulure de pompe en inox Socle de pompe Rondelle d’accouplement Rondelle de roue Joint torique de garniture mécaniqueJoint torique denveloppe extérieure Plaque-logementde dispositif d’étanchéitéSens DE Rotation ET D’ÉCOULEMENT Pompe Étages Sens de rotationSéries 5SV et 6SV IM018R07 Mars Serie G&L Modelo SSV Tema SERIES/SÉRIE/SERIESNúmero de etapas Accionamientos Ejemplo DE Código DE ProductoOpciones de juntas herméticas mecánicas Material y succión/descargaCarcasa del motor Opciones para la bomba opcionalOpciones de sellado Voltaje del motorInstrucciones DE Seguridad Tamaño de la bomba Bomba Número Presión máxima De etapas De entradaSeries 250º F PSI / Bar Nº de arranquesPulgadas mm Alineación Angular TuberíasConexión DE Agua Cableado Y Conexión a TierraCEBADO/VENTILACIÓN Funcionamiento Intervalo Entorno de Servicio Lubricación DEL MotorOpciones DE Juntas Herméticas Mecánicas NúmeroRecambio DE Juntas Herméticas Mecánicas Tamaños 33SV-92SV GiratorioPage Síntoma Causa ProbableDel motor Adaptador 4SV 33-92SV Valores DE TorquePerno Brida del Acoplamiento Tuercas de VentilaciónComponentes Principales DE 1SV, 2SV, 3SV Y 4SV SIN Pistón CON Pistón Series 5SV y 6SV Dirección DE Flujo Y Rotación DEL MotorTamaño Etapa ObsoletasDeclaration of Conformity