ITT SSV manual Wiring and Grounding, Priming/Venting

Page 9

For the 33 through 92SV sizes using a cartridge seal, after coupling bolts have been properly torqued, there are four set screws on the collar of the car- tridge seal that require tightening before removing the shim. The four hex head set screws require a 1/8" allen wrench and are to be tightened hand-tight ap- proximately 5 lbs.-ft. (7 Nm).

Remove the motor assembly shim and retain for future use.

Install the 2 coupling guard halves.

1. Water Connection

The water connections must be made by qualified installation technicians in compliance with the regu- lations in force.

In case of connection to the water system, the regu- lations issued by the competent authorities (mu- nicipal, public utility company) must be observed. Authorities often require the installation of a back- flow prevention device, such as a disconnector, check valve or disconnection tank.

2. Wiring and Grounding

Single Phase Motors – Connect the BLACK wire to the BLACK motor wire. Connect the WHITE wire to the WHITE motor wire. Connect the GREEN wire to the GREEN motor wire.

Three Phase Motors – See figure below.

208-230V 3/60

 

 

460V 3/60

 

 

 

4

 

 

 

4

 

 

 

5

 

 

 

7

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

5

 

 

 

 

 

 

 

 

 

LEADSMOTOR

7

L1

LEADSCABLEPOWER

LEADSMOTOR

8

G

LEADSCABLEPOWER

G

 

 

 

 

 

 

 

 

 

2

 

 

 

6

 

 

 

L2

 

 

 

 

 

 

 

 

 

9

 

 

 

8

 

 

 

1

L1

 

 

3

 

 

 

 

 

L3

 

 

2

L2

 

 

9

 

 

 

 

 

 

 

3

L3

 

 

 

 

 

 

 

THREE PHASE MOTOR WIRING DIAGRAM

NOTICE: UNIT ROTATION IS DETERMINED WHEN VIEWED FROM MOTOR END. SEE PAGE 16 FOR MOTOR ROTATION DETAIL. INCOR- RECT ROTATION MAY CAUSE DAMAGE TO THE PUMP AND VOIDS WARRANTY.

Check pump rotation by observing the motor fan or

WARNING

Hazardous voltage can shock, burn or cause death.

Install, ground and wire accord- ing to local and National Elec- trical Code requirements.

Install an all leg disconnect switch near pump.

Disconnect and lockout electri- cal power before installing or servicing pump.

the coupling THROUGH the coupling guard. DO NOT confuse the flow arrows, stamped on the pump body, with the rotation arrows on the coupling and motor adapter. Three phase motors only – If rotation is incorrect, have a qualified electrician interchange any two of the three power cable leads.

3. Priming/Venting

For installations with the liquid level above the pump:

Electrical supply MUST match pump’s name- plate specifications. Incorrect voltage can cause fire, damage motor and voids warranty.

Motors equipped with automatic thermal pro- tectors open the motor’s electrical circuit when an overload exists. This can cause the pump to

start unexpectedly and without warning.

Use only stranded copper wire to motor and ground. Wire size MUST limit the maximum voltage drop to 10% of the motor nameplate voltage, at the motor terminals. Excessive voltage drop will affect perfor- mance and void motor warranty. The ground wire must be at least as large as the wires to the motor. Wires should be color coded for ease of mainte- nance.

Three phase motors require all leg protection with properly sized magnetic starters and thermal over- loads.

Close the discharge valve. Remove the vent plug.

For models 1SV and 2SV only, it is necessary to fully unscrew the pin located in the drain plug. See figure below.

DRAIN PLUG

DRAIN PLUG

WITH PIN CLOSED

WITH PIN OPEN

WARNING

Hazardous voltage

PERMANENTLY GROUND THE PUMP, MOTOR AND CONTROLS PER NEC OR LOCAL CODES BEFORE CONNECTING TO ELECTRICAL POWER. FAILURE TO DO SO CAN CAUSE SHOCK, BURNS OR DEATH.

For sizes 33SV-92SV the vent plug is supplied with an internal needle valve, so it is not neces- sary to remove the vent plug. Simply unscrew the needle valve half way to open the valve

to allow air to escape. (For sizes 33SV-92SV, if the pump is supplied with a cartridge seal, remove the vent plug located on the gland plate beneath the coupling.)

Connect the electrical leads to the motor, as follows:

Open the suction valve until liquid flows out of the vent plug opening.

Image 9
Contents ITT Subject Number of Stages SV a 1 D 2 B 0 HDriver Hertz/RPMExample Product Code Maintain ALL Safety Decals Read this manual before installing and using the productMinimum Inlet Suction Pressure Pump Number Maximum Stages Inlet Pressure PhaseSeries At 250º F PSI / Bar Pump Size3SV AnchoringInches mm Site SelectionPiping Shim203 Priming/Venting Wiring and GroundingMachinery HazardousVoltage Motor LubricationCode Rotary Stationary Upper plate, as requiredPage Power Consumption TOO High SymptomMotor not Running Excessive Noise and VibrationMotor Motor Bolt Torque ValuesCoupling 4SV 33-92SVPage Less Piston With Piston Size Stage Motor Rotation Flow Direction and Motor RotationSeries 5SV and 6SV 3SV and 4SVIM018R07 March Modèle SSV Série G&L Series Série Series SujetExemple DE Code DE Produit Code et choix de dispositifs d’étanchéité Choix de pompesCarcasse de moteur = abritée = fermée autoventilée = antidéflagrantePression D’ASPIRATION Minimale Consignes DE SécuritéPompe Pompe Étages MPa Bars, lbf/po²Débit min 500 r/min 900 r/min Pompe 33SV 46SV 66SV 92SV Débit min 500 r/minMm po NON Oblique EN Haut TuyauterieRéglage DE LA Position DE Larbre DE Pompe CaleDonnées Techniques Raccordement À LA TuyauterieCâblage ET Mise À LA Terre Lubrification DU Moteur MachinerieÉlasto Usage Code ÉlémentCode Code ET Choix DE Dispositifs DétanchéitéPage Ture Mécanique AnomalieVibration ET Bruit Excessifs Cause ProbableMoteur Couple DE SerrageAccouplement Adaptateur 1SV à 4SV 33SV à 92SVGarniture mécanique Tirants d’assemblage Joint toriqueTubulure de pompe en inox Socle de pompe Joint torique denveloppe extérieure Joint torique de garniture mécaniqueRondelle d’accouplement Rondelle de roue Plaque-logementde dispositif d’étanchéitéSens DE Rotation ET D’ÉCOULEMENT Pompe Étages Sens de rotationSéries 5SV et 6SV IM018R07 Mars Serie G&L Modelo SSV SERIES/SÉRIE/SERIES TemaOpciones de juntas herméticas mecánicas Ejemplo DE Código DE ProductoNúmero de etapas Accionamientos Material y succión/descargaOpciones de sellado Opciones para la bomba opcionalCarcasa del motor Voltaje del motorInstrucciones DE Seguridad Series 250º F PSI / Bar Bomba Número Presión máxima De etapas De entradaTamaño de la bomba Nº de arranquesPulgadas mm Tuberías Alineación AngularCableado Y Conexión a Tierra Conexión DE AguaCEBADO/VENTILACIÓN Funcionamiento Opciones DE Juntas Herméticas Mecánicas Lubricación DEL MotorIntervalo Entorno de Servicio NúmeroGiratorio Recambio DE Juntas Herméticas Mecánicas Tamaños 33SV-92SVPage Causa Probable SíntomaPerno Brida del Acoplamiento Valores DE TorqueDel motor Adaptador 4SV 33-92SV Tuercas de VentilaciónComponentes Principales DE 1SV, 2SV, 3SV Y 4SV SIN Pistón CON Pistón Tamaño Etapa Dirección DE Flujo Y Rotación DEL MotorSeries 5SV y 6SV ObsoletasDeclaration of Conformity