Weber PL - PG. 59 57205 manual Checking for GAS Leaks, Reinstall Control Panel

Page 15

PREPARING TO USE YOUR GRILL

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, which can cause serious bodily injury or death and damage to property.

mWARNING: The gas connections of your gas grill have been factory tested. We do, however, recommend that you leak check all gas connections before operating your gas grill.

mWARNING: Perform these leak checks even if your grill was dealer or store assembled.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

NOTE: All factory-made connections have been thoroughly checked for gas leaks and the burners have been flame-tested.As a safety precaution, however, you should check all fittings for leaks before using your Weber® gas grill. Shipping and handling may loosen or damage a gas fitting.

CHECKING FOR GAS LEAKS

You will need: A spray bottle or brush or rag and a soap and water solution. (You can make your own soap and water solution by mixing 20% liquid soap with 80% water; or, you can purchase leak check solution in the plumbing section of any hardware store.)

A) Turn gas supply on at source (1).

mWARNING: Do not ignite burners when leak checking.

B)To check for leaks, wet fittings with the soap and water solution, using a spray bottle, brush or rag. If bubbles form, or if a bubble grows, there is a leak. Apply the soap and water solution to the following connections:

a)Regulator hose-to-bulkhead connection (2).

b)Corrugated manifold hose-to-bulkhead connection (3).

c)Corrugated manifold hose-to-manifold connection (4).

d)Side burner hose-to-manifold connection (5).

e)Side burner hose-to-valve connection (6).

mWARNING: If there is a leak at connections (2, 3, 4, 5 or 6), turn off the gas, tighten the fitting with a wrench, and recheck for leaks with soap and water solution. If a leak persists

after tightening the fitting, turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

f)Regulator-to-cylinder connection (7).

g)Regulator hose-to-regulator connection (8).

h)Valves-to-manifold connections (9).

mWARNING: If there is a leak at connections (7, 8, or 9), turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

C)When leak checking is complete, turn gas supply off at the source and rinse connections with water.

NOTE: Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Reinstall Control Panel

You will need: A Phillips screwdriver.

A)Align valve stems with holes in control panel. Position top edge of control panel on tabs of frame assembly. Push control panel down into position.

B)Fasten control panel with screws.

C)Place control knobs onto valve stems.

D)Connect the wires to the igniter button.

mWARNING: Make sure that all parts are assembled and hardware is fully tightened before operating the grill.

Your actions, if you fail to follow this product warning, may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as damage to property.

Now you are ready to use your grill.

3

2 1

4

5

6 9

7 8

WWW.WEBER.COM® 15

Image 15
Contents LP GAS Grill OWNER’S Guide Additional Warnings For State of California Table of Contents WarrantySpiritE220LPUS042412 Panneau inférieur Roulette Roulette à verrouillage Spirit E220 LPSpiritE320LPUS042412 Spirit E320 LP Exploded View List Spirit E320 LPSpiritSP320LPUS042412 Spirit SP320 LP Exploded View List Spirit SP320 LPImportant Information about LP GAS What is Liquid Propane GAS?What is a REGULATOR? Important Information about LP GAS ConnectionsRegulator Connections LP Cylinder Installation and Removal Installing the LP CylinderFueling Your Grill Removal of the LP Cylinder Fuel LevelFilling the LP GAS Cylinder Improper Filling is DangerousConfirm that Grill Is Off What is a Leak CHECK?Partial Disassembly of Your Grill for a Leak Check Preparing to USE Your GrillChecking for GAS Leaks Reinstall Control PanelTips & Hints Grilling Tips & Helpful HintsCatch PAN and Disposable Drip PAN Safety Checks Before Using Your GrillSafety First SLIDE-OUT Grease TrayElectronic Crossover Ignition System Methods of Burner IgnitionMain Burner Ignition To Extinguish BurnerCan cause Main Burner Ignition & UsageLighting with a Match Control knobs, wait at least fiveTo Extinguish Side Burner Side Burner Ignition & UsageOn the Side Side Burner IgnitionSide Burner Ignition & Usage Troubleshooting General TroubleshootingSide Burner Troubleshooting Weber SPIDER/INSECT Screens Annual MaintenanceKeeping Your Weber GAS Grill in TIP-TOP Shape Burner Flame PatternRemove Manifold Burner Tube Cleaning Or ReplacementRemove Burner Tubes Burner Tube CleaningClean Burner Tubes Reinstall Burner Tubes Reinstall Manifold Beautiful Inside and OUT Routine MaintenanceCleaning the Outside of the Grill Cleaning the Inside of the GrillMaintaining the Electronic Crossover Ignition System Igniter Module Wire Chart E220 / E320 / SP320Reinstall Side Burner Valve Cleaning Side Burner TubeSide Burner Maintenance Clean the Burner TubeWEBER-STEPHEN Products LLC Guía DEL Propietario DE LA Barbacoa DE GAS Propano Licuado Advertencias AdvertenciasAdvertencias Adicionales Para EL Estado DE California Garantía Instalación Y Retiro DEL Cilindro DE GAS Propano LicuadoConsejos Prácticos Para Asar a LA Parrilla Códigos DE Instalación Canadienses Información Importante Acerca DEL GAS Propano LicuadoAlmacenaje Y/O Falta DE USO Códigos DE Instalación DE LOS EE.UUConexiones DEL Regulador ¿QUÉ ES UN REGULADOR?Instalación Y Retiro DEL Cilindro DE GAS Propano Licuado Combustible Para LA BarbacoaInstalación DEL Cilindro DE Propano Licuado Nivel DE Combustible Llenado DEL Cilindro DE GAS Propano LicuadoRetiro del cilindro de gas propano licuado Preparación Para Usar LA Barbacoa Asegúrese de que la barbacoa esté apagadaRetire el panel de control Vuelva a instalar el panel de control Pruebas DE Detección DE Fugas DE GASSistema Flavorizer Consejos Prácticos Para Asar a LA ParrillaPrecalentamiento Cocción CubiertaPlato Recolector Y Bandeja DE Goteo Desechable Chequeos DE Seguridad Antes DE Usar LA BarbacoaLA Seguridad Primero Bandeja Deslizante DE GrasaPara Apagar EL Quemador Encendido Y USO DEL Quemador PrincipalMétodos DE Encendido DEL Quemador Encendido DE LOS Quemadores PrincipalesEncendido con un cerillo De plástico alrededor dePara Apagar EL Quemador Lateral Encendido Y USO DEL Quemador LateralEN EL Lado Encendido DEL Quemador LateralEncendido Y USO DEL Quemador Lateral Resolución DE Problemas Solución DE Problemas GeneralesResolución DE Problemas CON EL Quemador Lateral Orificios DE LOS Tubos Quemadores Mantenimiento AnualPatrón DE LA Llama DEL Quemador Mallas Weber Contra Arañas Y Demás InsectosRetire el múltiple Limpieza O Reemplazo DE LOS Tubos DE LOS QuemadoresPara las barbacoas Spirit con 2 quemadores modelos 210 y Retire los tubos de los quemadoresLimpie los tubos del quemador Vuelva a instalar los tubos de los quemadores Vuelva a instalar el múltiple Mantenimiento DE Rutina Limpieza DEL Exterior DE LA BarbacoaLimpieza DEL Interior DE LA Barbacoa Mantenimiento DEL Sistema DE Encendido Electrónico Crossover Limpie el tubo del quemador Limpieza DEL Tubo DEL Quemador LateralMantenimiento DEL Quemador Lateral Retire la válvula del quemador lateralWEBER-STEPHEN Products LLC Mode D’EMPLOI DU Grill À GAZ PL Mises EN Garde Supplémentaires Pour L’ÉTAT DE Californie Mises EN GardesInformations Importantes SUR LE GAZ PL Maintenance DE RoutineGarantie Spirit E220 LP VUE Eclatee Spirit E320 LP VUE EclateeInformations Importantes SUR LE GAZ PL Informations Importantes SUR LES Raccords DE GAZ PL QU’EST-CE QU’UN Régulateur ?Raccordements DU Régulateur Installation ET Retrait DE LA Bouteille DE PL Installation DE LA Bouteille DE PLAlimenter Votre Grill Retrait de la bouteille de PL Niveau DE CombustibleRemplir LA Bouteille DE GAZ PL UN Remplissage Incorrect EST DangereuxMises EN Garde Retirez le panneau de commandeSE Préparer À Utiliser LE Grill QU’EST-CE QU’UNE DÉ Tection DES Fuites ?Détection DES Fuites DE GAZ Remettez en place le panneau de commandeTrucs & Astuces Trucs & Astuces Pour LA GrilladeÉgouttoir ET Égouttoir Jetable Contrôles DE Sécurité Avant D’UTILISER Votre GrillLA Sécurité D’ABORD Plateau DE Récupération DES Graisses AmoviblePour Éteindre LE Brûleur Allumage & Utilisation DU Brûleur PrincipalMéthodes Pour ’ALLUMAGE DU Brûleur Allumage DU Brûleur PrincipalAllumage à l’aide d’une allumette Pour Éteindre LE Brûleur Latéral Allumage & Utilisation DU Brûleur LatéralSUR LE Côté Allumage DU Brûleur LatéralVous devriez voir une flamme Dépannage Dépannage GénéralDépannage DU Brûleur Latéral Ports DU Tube DU Brûleur Conserver Votre Grill À GAZ Weber EN Parfait ÉtatAspect DE LA Flamme DU Brûleur Grilles ANTI-ARAIGNÉES Insectes WeberMaintenance Annuelle Nettoyage DU Tube DU Brûleur OU RemplacementRetirez le collecteur Retirez les tubes du brûleur Nettoyage DU Tube DU Brûleur OU Remplacement suiteNettoyez les tubes du brûleur Remettez en place les tubes du brûleur Il vous faudra Un tournevis cruciforme, deux clés de 7/16 Remettez en place le collecteurMaintenance DE Routine Nettoyage DE L’EXTÉRIEUR DU GrillNettoyage DE L’INTÉRIEUR DU Grill Guide DE Câblage DU Module D’ALLUMAGE E220 / E320 / SP320 Maintenance DU Système ’ALLUMAGE Électronique CrossoverNettoyez le tube du brûleur Maintenance DU Brûleur LatéralNettoyage DU Tube DU Brûleur Latéral Retirez la valve du brûleur latéralWEBER-STEPHEN Products LLC