PROGRAMMING continued
3.Pressto enter the Programming Mode. “PROGRAMMING MODE MENU ITEMS” is displayed.
4.Pressthree, (3) times. “PROGRAMMING MODE PROD NAME LIB” is displayed.
5.Press. “PROD NAME LIB” is displayed.
6.Press. “PROD NAME LIB” will be displayed on the top line, with a flashing cursor on the bottom line.
7.Useandto change the character,
8.Pressto save the new product name. “SAVE LIBRARY ADD” is displayed.
9.Pressto save. “PROGRAMMING MODE PROD NAME LIB” is displayed.
10.Press to exit.
To Modify a Product Name in Library:
1.Press and hold for three, (3) seconds. “ENTER CODE” is displayed.
2.Using the Product buttons,
3.Press to enter the Programming Mode. “PROGRAMMING MODE MENU ITEMS” is displayed.
4.Press three, (3) times. “PROGRAMMING MODE PROD NAME LIB” is displayed.
5.Press. “PROD NAME LIB” is displayed.
6.Useandto select Product Name to be modified.
7.Press . The first character in the Product Name will start flashing.
8.Use and to change the character,
9.Press. “SAVE LIBRARY ADD” is displayed.
10.Press. “SAVE LIBRARY MODIFY” is displayed.
11.Press to save. “PROGRAMMING MODE PROD NAME LIB” is displayed.
12.Press to exit.
Service Mode
To Change SCK Address:
1.Press and hold for three, (3) seconds. “ENTER CODE” is displayed.
2.Using the Product buttons,
3.Press to enter the Programming Mode. “PROGRAMMING MODE MENU ITEMS” is displayed.
4.Press three, (3) times. “PROGRAMMING MODE SERVICE MODE” is displayed.
5.Pressone, (1), time. “Address XX” is displayed.
6.Useandto change to the desired SCK Address.
7.Pressto save the changes.
8.Press to return to “PROGRAMMING MODE SERVICE MODE”
9.Pressagain to exit.
To Perform Limit Switch Test:
1.Press and hold for three, (3) seconds. “ENTER CODE” is displayed.
2.Using the Product buttons,
3.Press to enter the Programming Mode. “PROGRAMMING MODE MENU ITEMS” is displayed.
4.Press three, (3) times. “PROGRAMMING MODE SERVICE MODE” is displayed.
5.Press two, (2), times. “PLATEN” (along with the position of each switch), is displayed.
6.Use and to move the platen up and down. Check for correct switch operation:
Correct Switch Operation: Platen Up - U (Closed) L (Open) Platen Down - U (Open) L (Closed)
7.Press to return to “PROGRAMMING MODE SERVICE MODE”.
8.Pressagain to exit.
Page 32 | Part # JIBSM08 Rev 7 (08/04/09) |