Garland XG24-JIB, XG36-JIB service manual Wiring Diagram

Page 83

 

Z

GREEN

E

TB1

 

 

WHITE - BLK

Z

L3A

 

 

 

 

 

 

 

Y

3

GND

Y

BLACK

L2A

 

 

 

X

 

X

RED

 

 

 

 

 

 

NEMA 15-50P

 

 

L1A

 

 

 

 

TO OTHER SECTION CIRCUIT BREAKERS

M

FAN MOTOR

S8

S8/1

S8/2

SSR3 GRIDDLE

61A

66A 63A

62A

64A

65A

PRESSURE SWITCH

 

 

 

 

IGN

G N

T

S

V

V

 

 

 

67A

69A

 

IGNITER

J68

SOLENOID VALVE

68A

70A

 

J69

WIRING DIAGRAM

CIRCUIT BREAKER

CONTROL & MOTOR CIRCUITS

1

TB2 120 V DIST.

 

 

5A Fuse

3

5A Fuse

65A

61A

TO OTHER

MOTOR CIRCUITS

L3A

L2A

L1A

CB PLATEN

 

 

 

S1

P1

 

 

CONTACTOR

SSR1

1

1

 

 

 

 

L3A

T3A

6A

6

 

 

L2A

 

T2A

2

2

T2

 

 

 

 

 

 

 

 

SSR2

3

3

 

L1A

T1A

7A

7

 

 

4A

 

 

4

4

4

 

 

 

 

 

 

 

 

 

PLATEN HEATERS

1333W

1333W

HI LIMIT

1333W

60A

S3

P3

5A Fuse

4

240V

120V

7

1 2 5 6

1 2 5 6

TO OTHER

HI-LIMITS

TO OTHER

IGNITION CIRCUITS

TO OTHER

CTRL XFMRS

TO OTHER

CONTACTORS

TO OTHER

CTRL XFMRS

TO OTHER

MOTOR CIRCUITS

TO OTHER

IGNITION CIRCUITS

8A

4A

3A

9A

120V

5A

5

5

5

 

 

8A

6

6

8

 

 

3A

 

 

 

 

1A

 

 

 

 

 

 

 

 

2A

P2/4

J3/3

J3/1

P2/1

12A

 

 

 

 

 

P2/3

J3/4

J3/2

P2/2

10A

 

 

 

 

 

 

 

 

UPPER LIMIT SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

J2/5

J2/1

 

51

 

NC

COMM

 

 

P5/5

P5/1

 

 

 

 

 

 

 

 

NO

COMM

 

 

 

 

J2/6

J2/2

 

52

 

 

 

P5/6

P5/2

 

 

 

 

 

 

 

11

LOWER LIMIT SWITCH

 

 

 

 

 

 

J2/11

 

 

 

 

 

P5/7

J2/7

P5/11

 

 

P6

S6

 

 

 

 

 

 

MOTOR

12A +

M

10A -

ENCODER

5V

PULSE

GROUND

ACTUATOR

MAIN SWITCH

 

 

 

24V

 

 

PILOT LAMP

 

33

31

P4/1

J1/1

 

 

 

 

 

 

 

 

 

 

P4/3

J1/3

RAISE SWITCH

STBY SWITCH

 

 

 

 

 

 

P7/3

38

P4/8

J1/8

 

 

P7/2

39

P4/9

J1/9

 

 

P7/1

35

P4/5

J1/5

 

 

35A

 

 

 

S7

P7

 

 

 

 

 

 

 

 

J2/1

 

 

 

 

 

J2/2

67A

MAIN CONTROL

PLATEN RED

PLATEN YELL

GRIDDLE RED

GRIDDLE YELLOW

69A

 

 

 

 

 

J2/8

J2/3

 

13

13

P6/3

 

 

 

 

 

P5/3

 

 

 

 

 

 

P5/8

 

 

 

 

 

 

 

 

 

 

 

 

14

P6/2

 

10

P4/10

 

J2/9

J2/4

P5/4

14

J1/

40

P5/9

J2/12

12

12

P6/1

J1/

11

P4/11

41

J2/10

P5/12

 

P5/10

 

 

 

 

J1/

12

P4/12

42

MOTOR CONTROL

 

 

 

 

 

J1/

13

P4/13

43

 

 

 

 

35D

 

 

 

 

 

 

 

 

 

 

J1/

14

P4/14

44

 

 

 

24A

SSR1 PLATEN

 

 

 

 

 

 

 

 

 

 

 

J1/

15

P4/15

45

 

 

 

 

35D

 

 

 

 

 

 

 

 

 

 

 

J1/

4

P4/4

 

24

 

24

 

35C

 

 

 

 

 

 

 

 

 

 

SSR2 PLATEN

 

 

 

 

 

 

 

 

 

35A

 

 

 

 

 

 

35A

 

 

 

 

 

J1/

6

P4/6

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOCOUPLE GRIDDLE

 

 

26

35C

 

 

 

 

 

 

-

 

 

 

35B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

SSR3 GRIDDLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOCOUPLE PLATEN

 

 

 

 

 

 

 

 

 

 

-

 

 

 

35B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

26A

35A

 

 

 

 

 

 

 

 

 

ELECTRIC ONLY

 

 

 

 

 

 

 

 

 

 

 

 

Total

Loading kW Per Phase

 

Nominal Amps Per Line

 

OTHER SECTIONS HAVE THE SAME WIRING DIAGRAM.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: THIS IS THE DIAGRAM OF ONE SECTION ONLY.

 

Model

kW

 

 

 

 

 

 

 

 

 

 

 

208/240V 3ph

208V 3-Phase Delta

240V 3-Phase Delta

 

 

 

Load

 

 

 

 

 

 

 

 

 

 

 

 

X-Y

X-Z

Y-Z

X

Y

Z

X

Y

Z

WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XG36-JIB

 

XG36-JIB

12.99

4.00

4.99

4.00

37.43

33.30

37.43

32.43

28.90

32.43

 

208-240

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCE 45203S65

 

 

 

 

 

 

 

 

 

 

 

VOLT 60HZ

Page 83

6/09

2008

Image 83
Contents Jack in the BOX GAS Xpress GRILLS, Models XG24-JIB, XG36-JIB Table of Contents Table of Contents Dimensions and SPECIFICATIONS, XG24-JIB Model Dimensions and SPECIFICATIONS, XG36-JIB Model Plug Configuration SpecificationsIntroduction SafetyWarranty Shipping Damage Claim ProcedureSafety National Codes Requirements Unit InstallationRating Plate Location General InformationElectrical Connections Unit InstallationAccessory Kit Main Gas Inlet Appliances Equipped with CastersAccessory Kit Electrical Supply Lines Changing to a different type of gas Electrical Connection Terminal Block ConnectionGrease Bucket Ventilation and ClearanceIgniter Inspection Burner Air AdjustmentIgniter Adjustment Grill Controls Grill Controls Platen Zeroing Programming Mode System SetupLower Front Left Raise Back Right Platen ZeroingOptional Accessories Release material sheet must be replaced when Release Material InstallationNormal Operation Normal Operation Daily Cleaning Cleaning and MaintenanceCleaning During Operation Cleaning and Maintenance Programming Modes/Menu Sequence ProgrammingProgramming To Change the Cook Time of a Product To Change Upper Platen Set TemperatureTo Change Grill Set Temperature To Change Product Gap SettingTo Change a Product Name To View Recovery Time Upper PlatenTo View Recovery Time Grill To Change Product Button,KeyAssignmentTo View the Software Number To Change temperature Units, F or CTo Change Gap Setting Display Units To View the Flash NumberTo Change Probe Calibration Grill To Change the Alarm VolumeTo Change the Key Chirp To Change Probe Calibration UpperTo Turn Extended Time On/Off To Change Platen SetTo Change Instant-On Time To Change Control TypeTo Change the Grill Function To Change the Start DelayTo Change the Alarm Mode To Turn Clean Mode On/OffTo Change SCK Address To Perform Limit Switch TestTo Modify a Product Name in Library To Calibrate CalibrationBi-Weekly Calibration Probe Locations CalibrationError Messages TroubleshootingLow Internal Product Temperatures Technical TroubleshootingYES Technical TroubleshootingController Displays Too Hot YES Controller displays Probe Error Upper platen is not zeroed properly Inconsistent Or Erratic Internal Product TemperatureProbable diagnosis YES Check voltage of upper limit Does Upper Limit YES Controller Displays Ignition Failure No flame at allNoyes Linear Actuator Replacement Linear Actuator Replacement JIBSM08 Rev 7 08/04/09 Contents Parts ListModel XG24-JIB Description Quantity Gas Xpress Grill Complete Exploded View Model XG24-JIBXpress Grill Actuator Gas Xpress Grill Actuator Assembly View Model XG24-JIB Xpress Grill Platen 4517022 Platen Conduit Gas Xpress Grill Platen Assembly View Model XG24-JIBXpress Grill Burner Gas Xpress Grill Burner Assembly View Model XG24-JIB Assembly View Model XG24-JIB Ignition Module Component BracketContactor Bracket Xpress Grill Heat Sink Assembly View Model XG24-JIB Gas Xpress Grill Heat Sink Assembly View Model XG24-JIB Part List Book Released Revision HistoryREV. # Item #Right Zone Parts ListGrill Complete Assembly Description Quantity Critical Gas Xpress Grill Complete Exploded View Model XG36-JIB4520578 Grill Plate Thermocouple JIBSM08 Rev.6 08/04/09 Actuator Assembly GAS Xpress Grill Actuator Assembly View Model XG36-JIB Platen Assembly Gas Xpress Grill Platen Assembly View Model XG36-JIB Assembly View Model XG35-JIB Gas Xpress Grill Burner Assembly View Model XG36-JIB Xpress Grill Bracket Component Mounting Bracket Xpress Grill Heat Sink Assembly View Model XG36-JIB Gas Xpress Grill Heat Sink Assembly View Model XG36-JIB Description & Location Quantity Critical Gas Xpress Grill Accessories And Tools Model XG36-JIB Center Zone Right Zone Left Zone Gas Xpress Grill Gas Tubing Model XG36-JIBItem # Date Revision HistoryDiagram WiringWiring Diagram Time Controller Menu ItemsJack in the Box Menu Items Temperature Conversion F / C Page JIBSM08 Rev.6 08/04/09