Garland XG36-JIB service manual Dimensions and SPECIFICATIONS, XG24-JIB Model

Page 4

DIMENSIONS AND SPECIFICATIONS, XG24-JIB MODEL

 

Total

Loading kW Per Phase

 

Nominal Amps Per Line

 

 

 

 

 

 

 

 

 

 

 

Model

kW

208/240V 3ph

208V 3-Phase Delta

240V 3-Phase Delta

 

Load

X-Y

X-Z

Y-Z

X

Y

Z

X

Y

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

XG24-JIB

8.66

2.66

3.33

2.66

24.90

22.14

24.90

21.61

19.19

21.61

 

 

 

 

 

 

 

 

 

 

 

6’ (1.83m) electric cord and plug included in supplied accessory kit: 240V models are supplied with a #4-10AWG cord with a NEMA 5-30P plug, kit # 4525509. 208V models are supplied with a #4-6AWG cord with a NEMA 15-50P plug, kit # 4524785.

 

Clearances

 

 

Gas Pressure

 

Total Gas Input

 

 

 

 

 

 

 

 

Entry

Installation

Supply (min.)

Operating

 

 

Crated

Uncrated

Sides

Rear

NAT

PRO

NAT

PRO

BTU/Hr

kW

 

 

 

 

 

 

 

 

 

 

47-1/2"

32"

6"

3"

7.0" WC

11.0" WC

3.5" WC

3.5 " WC

66,000

19.4

(1207mm)

(813mm)

(152mm)

(76mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP HEATER

 

 

11 1/2"

TOP VIEW

1 3/4"

[292mm]

 

 

G

[44mm]

 

 

24"

 

40"

[610mm]

 

 

[1016mm]

 

 

GRILL PLATE 24" X 24"

 

[610mm X 610mm]

 

Shipping: Weight 575Lbs/ 234Kg, 45 Cubic Feet

Garland products are not approved or authorized for home or residential use, but are intended for commercial applications only. Garland will not provide service, warranty, maintenance or support of any kind other than in commercial applications

Gas input ratings shown here are for installations up to 2,000 Ft. (610m) above sea level. Specify altitudes over 2,000 Ft.

35"

 

 

 

 

 

[889mm]

 

 

 

 

 

 

 

26 3/16"

 

61 1/4"

 

 

 

[1556mm]

 

 

[665mm]

34"

FRONT

 

GRILL

[864mm]

 

 

PLATE

RIGHT SIDE VIEW

 

 

VIEW

 

HEIGHT

 

 

 

 

 

3/4"

MIN 6"

 

 

 

GAS INLET

 

9"

 

35 5/8"

 

[152mm]

 

[229mm]

TOLERANCE

[905mm]

 

MAX 9"

 

 

 

 

[229mm]

 

 

+/- 1/8" [3mm]

 

 

 

Page 4

Part # JIBSM08 Rev 7 (08/04/09)

Image 4
Contents Jack in the BOX GAS Xpress GRILLS, Models XG24-JIB, XG36-JIB Table of Contents Table of Contents Dimensions and SPECIFICATIONS, XG24-JIB Model Dimensions and SPECIFICATIONS, XG36-JIB Model Specifications Plug ConfigurationSafety WarrantyShipping Damage Claim Procedure IntroductionSafety Unit Installation Rating Plate LocationGeneral Information National Codes RequirementsUnit Installation Accessory Kit Main Gas InletAppliances Equipped with Casters Electrical ConnectionsAccessory Kit Electrical Supply Lines Electrical Connection Terminal Block Connection Grease BucketVentilation and Clearance Changing to a different type of gasIgniter Adjustment Burner Air AdjustmentIgniter Inspection Grill Controls Grill Controls Programming Mode System Setup Platen ZeroingPlaten Zeroing Lower Front Left Raise Back RightOptional Accessories Release Material Installation Release material sheet must be replaced whenNormal Operation Normal Operation Cleaning During Operation Cleaning and MaintenanceDaily Cleaning Cleaning and Maintenance Programming Programming Modes/Menu SequenceProgramming To Change Upper Platen Set Temperature To Change Grill Set TemperatureTo Change Product Gap Setting To Change the Cook Time of a ProductTo View Recovery Time Upper Platen To View Recovery Time GrillTo Change Product Button,KeyAssignment To Change a Product NameTo Change temperature Units, F or C To Change Gap Setting Display UnitsTo View the Flash Number To View the Software NumberTo Change the Alarm Volume To Change the Key ChirpTo Change Probe Calibration Upper To Change Probe Calibration GrillTo Change Platen Set To Change Instant-On TimeTo Change Control Type To Turn Extended Time On/OffTo Change the Start Delay To Change the Alarm ModeTo Turn Clean Mode On/Off To Change the Grill FunctionTo Modify a Product Name in Library To Perform Limit Switch TestTo Change SCK Address Bi-Weekly Calibration CalibrationTo Calibrate Calibration Probe LocationsTroubleshooting Error MessagesTechnical Troubleshooting Low Internal Product TemperaturesController Displays Too Hot Technical TroubleshootingYES YES Controller displays Probe Error Inconsistent Or Erratic Internal Product Temperature Upper platen is not zeroed properlyProbable diagnosis YES Check voltage of upper limit Does Upper Limit Controller Displays Ignition Failure No flame at all YESNoyes Linear Actuator Replacement Linear Actuator Replacement JIBSM08 Rev 7 08/04/09 Parts List ContentsModel XG24-JIB Gas Xpress Grill Complete Exploded View Model XG24-JIB Description QuantityXpress Grill Actuator Gas Xpress Grill Actuator Assembly View Model XG24-JIB Xpress Grill Platen Gas Xpress Grill Platen Assembly View Model XG24-JIB 4517022 Platen ConduitXpress Grill Burner Gas Xpress Grill Burner Assembly View Model XG24-JIB Assembly View Model XG24-JIB Contactor Bracket Component BracketIgnition Module Xpress Grill Heat Sink Assembly View Model XG24-JIB Gas Xpress Grill Heat Sink Assembly View Model XG24-JIB Revision History REV. #Item # Part List Book ReleasedParts List Right ZoneGrill Complete Assembly Gas Xpress Grill Complete Exploded View Model XG36-JIB Description Quantity Critical4520578 Grill Plate Thermocouple JIBSM08 Rev.6 08/04/09 Actuator Assembly GAS Xpress Grill Actuator Assembly View Model XG36-JIB Platen Assembly Gas Xpress Grill Platen Assembly View Model XG36-JIB Assembly View Model XG35-JIB Gas Xpress Grill Burner Assembly View Model XG36-JIB Xpress Grill Bracket Component Mounting Bracket Xpress Grill Heat Sink Assembly View Model XG36-JIB Gas Xpress Grill Heat Sink Assembly View Model XG36-JIB Description & Location Quantity Critical Gas Xpress Grill Accessories And Tools Model XG36-JIB Gas Xpress Grill Gas Tubing Model XG36-JIB Center Zone Right Zone Left ZoneRevision History Item # DateWiring DiagramWiring Diagram Jack in the Box Menu Items Controller Menu ItemsTime Temperature Conversion F / C Page JIBSM08 Rev.6 08/04/09