Garland XG36-JIB Unit Installation, Appliances Equipped with Casters, Electrical Connections

Page 10

UNIT INSTALLATION continued

The grill must be disconnected from the gas supply system when pressure testing of that system at pressures in excess of 1/2 psi (3.45kPa).

Check the data plate to determine the proper type of gas before connecting the quick disconnect or piping from the building gas supply.

An incoming gas pressure test nipple is provided on the incoming gas manifold for pressure checks.

Minimum incoming gas pressure for Natural Gas is 6" W.C. Maximum incoming gas pressure for Natural Gas is 13" W.C.

Minimum incoming gas pressure for Propane is 10" W.C. Maximum incoming gas pressure for Propane is 13" W.C.

Burner operating gas pressure can be checked at the outlet side of the gas valve at the pressure test point.

Burner manifold pressure for Natural Gas must be 3.2" W.C.; Burner pressure for Propane must be 3.5" W.C.

To adjust the burner pressure, remove the sealing screw from the pressure test nipple, connect a manometer, remove the sealing cap on the gas valve regulator, turn on the grill, adjust the screw in the regulator to give the correct pressure, turn off the grill, refit the regulator sealing cap, remove the manometer, replace the seal screw in the test nipple and test for gas leaks.

Gas pressures should be checked by the local Gas Company or an authorized service agency only.

Test all piping and connections for gas leaks. A rich soap solution should be used for this purpose. Never use a flame.

Appliances Equipped with Casters:

1.The installation shall be made with a connector that complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B- 2006/CSA 6.16B-2006 (or latest edition), and a quick- disconnect device that complies with the Standard for Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/ CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005 (or latest edition).

2.The front casters on the appliance are equipped with brakes to limit the movement of the appliance without placing any strain on the connector or quick-disconnect device or its associated piping.

3.Please be aware; required restraint is attached to a bracket (which is located on the rear caster closest to the gas connection), and if disconnection of the restraint

is necessary; be sure to reconnect the device after the appliance has been returned to its original position.

Electrical Connections:

All electrically operated appliances must be electrically grounded in accordance with local codes; or in the absence of local codes, with the latest edition of National Wiring Regulations. A wiring diagram is located on the rear panel of the grill. See rating plate in rear of grill, or lower front panel for proper voltages.

Accessory Kit – Main Gas Inlet:

(Accessory kit part numbers 4524785 or 4525509 and also includes electrical supply lines, see next section)..

Each griddle is supplied with an extended rear gas manifold kit., with the following parts.

DESCRIPTION

PART DRAWING QTY.

3/4”x 3/4” 90 Degree Elbow

1

Nipple Assembly

1

Manifold Support Bracket

1

 

 

10-24 x 1/2 Quadrex

4

Pan HD Type F Screw

 

Installation of Kit:

A.Install the elbow on the end of manifold (3/4” NPT) underneath the griddle, tighten and align with the elbow facing the back of the unit. Refer to Photo A.

Photo A

Page 10

Part # JIBSM08 Rev 7 (08/04/09)

Image 10
Contents Jack in the BOX GAS Xpress GRILLS, Models XG24-JIB, XG36-JIB Table of Contents Table of Contents Dimensions and SPECIFICATIONS, XG24-JIB Model Dimensions and SPECIFICATIONS, XG36-JIB Model Specifications Plug ConfigurationShipping Damage Claim Procedure SafetyWarranty IntroductionSafety General Information Unit InstallationRating Plate Location National Codes RequirementsAppliances Equipped with Casters Unit InstallationAccessory Kit Main Gas Inlet Electrical ConnectionsAccessory Kit Electrical Supply Lines Ventilation and Clearance Electrical Connection Terminal Block ConnectionGrease Bucket Changing to a different type of gasIgniter Adjustment Burner Air AdjustmentIgniter Inspection Grill Controls Grill Controls Programming Mode System Setup Platen ZeroingPlaten Zeroing Lower Front Left Raise Back RightOptional Accessories Release Material Installation Release material sheet must be replaced whenNormal Operation Normal Operation Cleaning During Operation Cleaning and MaintenanceDaily Cleaning Cleaning and Maintenance Programming Programming Modes/Menu SequenceProgramming To Change Product Gap Setting To Change Upper Platen Set TemperatureTo Change Grill Set Temperature To Change the Cook Time of a ProductTo Change Product Button,KeyAssignment To View Recovery Time Upper PlatenTo View Recovery Time Grill To Change a Product NameTo View the Flash Number To Change temperature Units, F or CTo Change Gap Setting Display Units To View the Software NumberTo Change Probe Calibration Upper To Change the Alarm VolumeTo Change the Key Chirp To Change Probe Calibration GrillTo Change Control Type To Change Platen SetTo Change Instant-On Time To Turn Extended Time On/OffTo Turn Clean Mode On/Off To Change the Start DelayTo Change the Alarm Mode To Change the Grill FunctionTo Modify a Product Name in Library To Perform Limit Switch TestTo Change SCK Address Bi-Weekly Calibration CalibrationTo Calibrate Calibration Probe LocationsTroubleshooting Error MessagesTechnical Troubleshooting Low Internal Product TemperaturesController Displays Too Hot Technical TroubleshootingYES YES Controller displays Probe Error Inconsistent Or Erratic Internal Product Temperature Upper platen is not zeroed properlyProbable diagnosis YES Check voltage of upper limit Does Upper Limit Controller Displays Ignition Failure No flame at all YESNoyes Linear Actuator Replacement Linear Actuator Replacement JIBSM08 Rev 7 08/04/09 Parts List ContentsModel XG24-JIB Gas Xpress Grill Complete Exploded View Model XG24-JIB Description QuantityXpress Grill Actuator Gas Xpress Grill Actuator Assembly View Model XG24-JIB Xpress Grill Platen Gas Xpress Grill Platen Assembly View Model XG24-JIB 4517022 Platen ConduitXpress Grill Burner Gas Xpress Grill Burner Assembly View Model XG24-JIB Assembly View Model XG24-JIB Contactor Bracket Component BracketIgnition Module Xpress Grill Heat Sink Assembly View Model XG24-JIB Gas Xpress Grill Heat Sink Assembly View Model XG24-JIB Item # Revision HistoryREV. # Part List Book ReleasedParts List Right ZoneGrill Complete Assembly Gas Xpress Grill Complete Exploded View Model XG36-JIB Description Quantity Critical4520578 Grill Plate Thermocouple JIBSM08 Rev.6 08/04/09 Actuator Assembly GAS Xpress Grill Actuator Assembly View Model XG36-JIB Platen Assembly Gas Xpress Grill Platen Assembly View Model XG36-JIB Assembly View Model XG35-JIB Gas Xpress Grill Burner Assembly View Model XG36-JIB Xpress Grill Bracket Component Mounting Bracket Xpress Grill Heat Sink Assembly View Model XG36-JIB Gas Xpress Grill Heat Sink Assembly View Model XG36-JIB Description & Location Quantity Critical Gas Xpress Grill Accessories And Tools Model XG36-JIB Gas Xpress Grill Gas Tubing Model XG36-JIB Center Zone Right Zone Left ZoneRevision History Item # DateWiring DiagramWiring Diagram Jack in the Box Menu Items Controller Menu ItemsTime Temperature Conversion F / C Page JIBSM08 Rev.6 08/04/09