UNIT INSTALLATION continued
The grill must be disconnected from the gas supply system when pressure testing of that system at pressures in excess of 1/2 psi (3.45kPa).
Check the data plate to determine the proper type of gas before connecting the quick disconnect or piping from the building gas supply.
An incoming gas pressure test nipple is provided on the incoming gas manifold for pressure checks.
Minimum incoming gas pressure for Natural Gas is 6" W.C. Maximum incoming gas pressure for Natural Gas is 13" W.C.
Minimum incoming gas pressure for Propane is 10" W.C. Maximum incoming gas pressure for Propane is 13" W.C.
Burner operating gas pressure can be checked at the outlet side of the gas valve at the pressure test point.
Burner manifold pressure for Natural Gas must be 3.2" W.C.; Burner pressure for Propane must be 3.5" W.C.
To adjust the burner pressure, remove the sealing screw from the pressure test nipple, connect a manometer, remove the sealing cap on the gas valve regulator, turn on the grill, adjust the screw in the regulator to give the correct pressure, turn off the grill, refit the regulator sealing cap, remove the manometer, replace the seal screw in the test nipple and test for gas leaks.
Gas pressures should be checked by the local Gas Company or an authorized service agency only.
Test all piping and connections for gas leaks. A rich soap solution should be used for this purpose. Never use a flame.
Appliances Equipped with Casters:
1.The installation shall be made with a connector that complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B- 2006/CSA
2.The front casters on the appliance are equipped with brakes to limit the movement of the appliance without placing any strain on the connector or
3.Please be aware; required restraint is attached to a bracket (which is located on the rear caster closest to the gas connection), and if disconnection of the restraint
is necessary; be sure to reconnect the device after the appliance has been returned to its original position.
Electrical Connections:
All electrically operated appliances must be electrically grounded in accordance with local codes; or in the absence of local codes, with the latest edition of National Wiring Regulations. A wiring diagram is located on the rear panel of the grill. See rating plate in rear of grill, or lower front panel for proper voltages.
Accessory Kit – Main Gas Inlet:
(Accessory kit part numbers 4524785 or 4525509 and also includes electrical supply lines, see next section)..
Each griddle is supplied with an extended rear gas manifold kit., with the following parts.
DESCRIPTION | PART DRAWING QTY. |
3/4”x 3/4” 90 Degree Elbow | 1 |
Nipple Assembly | 1 |
Manifold Support Bracket | 1 | |
|
| |
4 | ||
Pan HD Type F Screw | ||
|
Installation of Kit:
A.Install the elbow on the end of manifold (3/4” NPT) underneath the griddle, tighten and align with the elbow facing the back of the unit. Refer to Photo A.
Photo A
Page 10 | Part # JIBSM08 Rev 7 (08/04/09) |