Emerson oxymitterdr hazardous area in-siu oxygen probe, ib-106-340cdr Section Replacement Parts

Page 55

Hazardous Area Oxymitter DR

Instruction Manual

IB-106-340CDR Original Issue January, 2002

SECTION 7

REPLACEMENT PARTS

Table 7-1. Replacement Parts for Probe

Figure and Index No.

Part Number

Description

 

 

 

 

3D39496G061

V-Strut Assembly (18 in.)

 

3D39496G071

V-Strut Assembly (3 ft)

 

3D39496G081

V-Strut Assembly (6 ft.)

 

3534B56G042

Contact and Thermocouple Assembly (18 in.)

 

3534B56G052

Contact and Thermocouple Assembly (3 ft)

 

3534B56G062

Contact and Thermocouple Assembly (6 ft)

7-1

3535B44G013

Cell Replacement Kit (18 in.)

7-1

3535B44G023

Cell Replacement Kit (3 ft)

7-1

3535B44G033

Cell Replacement Kit (6 ft)

7-1

3535B44G04

Cell Replacement Kit (No Inconel and Platinum Pad Assembly)

7-2

1L03825G01

Probe Disassembly Kit

 

1U05677G04

F/A Diffuser Hub Assembly (Snubber Diffusor)

 

1U05677G06

F/A Diffuser Hub Assembly (For use with Abrasive Shield)

 

6292A74G02

Ceramic Diffusion Element Replacement Kit

 

1N04966H02

Abrasive Shield Assembly (3 ft)

 

1N04966H03

Abrasive Shield Assembly (6 ft)

 

1M03241H01

90° Elbow for Bypass

 

4507C26G07

Bypass Gas Pickup Tube (3 ft)

 

4507C26G08

Bypass Gas Pickup Tube (6 ft)

 

4507C26G09

Bypass Gas Pickup Tube (9 ft)

 

263C152G01

Reference Gas Set

 

771B635H01

Calibration Gas Rotometer

 

1L03650H01

F/A Diffusion Hub Setscrew

1 V-Strut assembly includes contact and thermocouple assembly.

7

2 Contact and thermocouple assembly includes platinum pad and inconel wire 3 Cell replacement kit includes platinum pad and inconel wire.

NOTE

The replacement parts listed above must be obtained only from the manu- facturer or his agent.

Rosemount Analytical Inc. A Division of Emerson Process Management

Replacement Parts 7-1

Image 55
Contents Oxymitter DR Essential Instructions Hazardous Area Oxymitter DR Table of ContentsList of Tables List of IllustrationsDefinitions PrefaceHazardous Area Oxymitter DR Section I. Identification Section II. Physical Data Section V. Health Hazard Data Section VI. Reactivity Data Section VII. Spill or Leak Procedures Section IX. Special Precautions Hazardous Area Oxymitter DR Technical Support Hotline Component Checklist of Typical System Package Contents Section Description and SpecificationsSystem Overview System Features System ConfigurationTypical System Installation Upgrading the Hazardous Area Oxymitter DR Abrasive Shield AssemblyFlame Arrestor Ceramic Diffusion Assembly Flame Arrestor Snubber Diffusion AssemblyView a View B Specifications Code Sensing Probe Type Product MatrixPart Number Description Calibration ComponentsSelecting Location Section InstallationMechanical Installation InstallationHazardous Area Oxymitter DR Installation Hazardous Area Oxymitter DR with Abrasive Shield Mounting Plate Outline Without Abrasive Shield With Abrasive ShieldOrienting the Optional Vee Deflector Electrical Installation Pneumatic Installation Connect O2 and Heater Thermocouple SignalsOverview System Setup132 Analog Electronics SetupG02 G04 Westinghouse Model 218A ELEC- Tronics SetupWestinghouse Model TC200 VERI- Trim Electronics Setup 11. Main PCB Model TC200 Eprom Replacement 12. Main PCB Model 132 Eprom Replacement Westinghouse Model 132 Digital Electronics Setup14. Heater Power Supply HPS 3000 Jumper Configuration World Class 3000 Intelligent Field Transmitter Setup15. DR Probe Wired to the ZA8C or a V8C Converter Yokogawa ZA8C and AV8C Converter Electronics SetupGeneral Section Startup and OperationHazardous Area Oxymitter DR Calibration Section Maintenance and ServiceHazardous Area Oxymitter DR Replacement OverviewHazardous Area Oxymitter DR Exploded View Terminal Block Replacement InstallHeater Strut Replacement Entire Probe ReplacementCell Replacement Heater Strut Assembly22220028 Replacement Procedure Ceramic Diffusion Element ReplacementThis refers to the ceramic diffusion element only General Also, do not get any cement onto the flame arrestor element Ceramic Diffusion Element ReplacementTermination Housing Connections Termination Housing WiringHazardous Area Oxymitter DR Probe Troubleshooting Section TroubleshootingSymptom Check Fault Remedy Hazardous Area Oxymitter DR Equipment Return Section Return of MaterialHazardous Area Oxymitter DR Replacement Parts for Probe Section Replacement PartsCell Replacement Kit BY-PASS Packages Section Optional AccessoriesO2 Calibration GAS Sequencer Hazardous Area Oxymitter DR Appendix A. Updating DR Oxymitter to Full Oxymitter Section AppendicesHazardous Area Oxymitter DR Figure A-1. Component Replacement Upgrade ProcedureFigure A-2. Terminal Block and Wiring Section Index Hazardous Area Oxymitter DR Warranty Hazardous Area Oxymitter DR Serial no Order no