Black & Decker ASI500 instruction manual Setting the Automatic SHUT-OFF Pressure Figure G

Page 8

90564808 AS1500.qxd:??????-00 BDL500 laser 5/18/10 9:56 AM Page 8

SETTING THE AUTOMATIC SHUT-OFF PRESSURE - FIGURE G

Note: The LCD will only show inflation pressures when the inflator is being used. In both inflation and pump mode the unit will show battery status.

To switch between the different units (psi, bar or kPa), press - & + buttons (21, 23) at the same time until the required units are displayed.

Press and hold either buttons - & + (21, 23) for 3 seconds until the display flashes.

While the display is flashing press the - or + (21, 23) until the required pressure is displayed.

After 3 seconds the display will flash and return to a reading of "0.0". This is normal.

Connect the universal valve adaptor and accessories, if required, to the item to be inflated, making sure that the lever of the valve adaptor is in the down position to lock it in place.

To start the inflator press the power button (22) on the LCD.

When the item to be inflated has reached the preset value the unit will automatically turn off. Note: You may notice the actual pressure reading may drop after a couple of seconds, this is normal.

To stop the inflator at any time press the power button (22) on the LCD.

Remove the valve adaptor or accessory from the inflated item and the 12 Volt adapter (8) from your vehicle's 12 Volt accessory socket.

Turn the main power switch (1) to the off position (b).

Note: If the main power switch is turned off, all settings will be lost and will need to be re- entered following the instructions under the heading 'Setting the automatic shut-off pressure'. This is a safety feature to prevent the risk of items OVER INFLATING.

USING THE INFLATOR AS A PRESSURE GAUGE

Switch the main power switch (1) to the inflate position (c fig. G).

Connect the universal valve adaptor (6) to the item to be checked.

The LCD will display the items pressure.

After checking, turn the main power switch (1) off and return the air hose to the storage location.

OPERATING THE HIGH-VOLUME PUMP

Note: Do not operate the pump when the vehicleʼs engine is running.

Note: Make sure that your 12 Vdc accessory socket is live. On some vehicles the accessory socket may only become live when the ignition key is in the accessory position. To inflate using the high-volume pump (i.e air mattresses, rafts, swimming pool floats): Note: The pump mode DOES NOT have an auto shut-off feature.

Switch the main power switch (1) to the pump position (a, fig. G).

Remove the high-volume hose (7) from the storage channel around the center of the unit and connect it to the high-volume pump inflate connection (10).

Insert the hose (with accessories if required) to the item to be inflated.

To start the pump press the power switch (22) on the LCD.

When the item is inflated as required or to stop the pump at any time press the power switch (22) on the LCD.

Remove the hose from the item and store it on the unit.

Turn the main power switch (1) to the off position (b fig. G).

To deflate using the high-volume pump (i.e air mattresses, rafts, swimming pool floats):

Note: The pump mode DOES NOT have an auto shut-off feature.

Switch the main power switch (1) to the pump position (a fig. G).

Remove the high-volume hose (7) from the storage channel around the center of the unit and connect it to the high-volume pump deflate connection (4) (fig. H).

Insert the hose (with accessories if required) into the item to be deflated.

To start the pump press the power switch (22) on the LCD.

When the item is deflated or to stop the pump at any time press the power switch (22) on the LCD.

Remove the high-volume hose (7) from the item and store it in the storage channel around the center of the unit.

Turn the main power switch (1) to the off position (b fig. G).

H

4

 

10

 

7

8

Image 8
Contents Cordless / 12VDC AIR Station VEA EL Español EN LA ContraportadaGeneral Safety Rules Additional Safety Warnings for Your Inflator Total Length of Cord in FeetNever carry the inflator by the hose Do not operate inflator when car engine is runningImportant Charging Notes Liquid Crystal Display Fluid First AID Measures Functional DescriptionCharging the Battery Figure a Fitting the Accessories Figures D,E,F & GIntroduction USEOperating the Inflator Figure G Quick StartOperating the HIGH-VOLUME Pump Setting the Automatic SHUT-OFF Pressure Figure GUsing the Inflator AS a Pressure Gauge Sleep Mode to Preserve Battery Life Replacing the Fuse in the Vehicle DC Accessory PlugBattery Removal for Recycling Figure MaintenanceAccessories Service Information Full ONE-YEAR Home USE WarrantyMode DʼEMPLOI Conserver CES Directives Règles Générales DE SécuritéIntensité nominale Le risque de choc électrique Remarques Importantes SUR LA Charge Description Fonctionnelle Charge DE LA Batterie Figure aRangement DU Tuyau ET DU Cordon Figures B-D Installation DES Accessoires Figures D, E, F ET GUtilisation Utilisation DU Dispositif DE Gonflage Figure G Démarrage RapideUtilisation DU Dispositif DE Gonflage Comme Manomètre Utilisation DE LA Pompe À Volume ÉlevéRégler LA Pression DʼARRÊT Automatique Figure G Mode DE Veille Pour Préserver LʼÉNERGIE DE LA Batterie Utilisation DU Voyant DELRetrait DE LA Batterie Pour LE Recyclage EntretienDépannage Problème Cause possible Solution possibleAccessoires Information SUR LES Réparations Garantie Complète DE UN AN Pour UNE Utilisation DomestiqueManual DE Instrucciones Normas Generales DE Seguridad AdvertenciasCapacidad nominal en amperios Advertenciasdeseguridadadicionalesparasuinflador Definiciones son los siguientes Carga DE LA Batería Figura a IntroducciónDescripción DE LAS Funciones USO Ajuste DE LOS Accesorios Figuras D, E, F & GAjuste DE LA Presión DE Apagado Automático Figura G Operación DEL Inflador Figura GInicio Rápido Operación DE LA Bomba DE Alto Volumen USO DEL Inflador Como UN ManómetroMantenimiento Operación DE LA LUZ LEDRetiro DE Baterías Para Reciclado FIG Problema Detección DE ProblemasCausa posible Solución posible AccesoriosEpecificaciones Información DE MantenimientoGarantía Completa DE UN AÑO Para USO EN EL Hogar AÑO DE Garantia Esta Garantia no Aplica CuandoSolamente Para Propositos DE Mexico