Tripp Lite 3-Phase 20kVA Service, Warranty & Warranty Registration, Observe Proper Polarity

Page 16

Adding or Replacing Internal Batteries (continued)

WARNING!

OBSERVE PROPER POLARITY!

Connect BLACK-to-BLACK and RED-to-RED. Failure to observe proper polarity will cause permanent damage to the UPS System and create a potential for serious personal injury.

13

14

15

16

Connect the BLACK cable for each internal battery pack to the nearest BLACK connector located inside the UPS system's battery module.

Connect the RED cable for each internal battery pack to the nearest RED connector located inside the UPS system's battery module.

Replace the battery access panel.

Return the UPS System to Normal Mode or completely turn it on, depending on the procedure you followed in step 1. See “Operation of Manual Bypass Switch” or “Turning the UPS On” in the Operation section.

13 / 14

Service

Your SmartOnline 3-Phase UPS System is covered by the limited warranty described below. Extended warranty (2-, 3- and 4-year) and start-up service programs are available. For more information, call Tripp Lite Customer Service at (773) 869-1234.

Warranty & Warranty Registration

3-Phase UPS System Limited Warranty

Seller warrants this product, if used in accordance with all applicable instructions as verified by Tripp Lite's "Start-up" service, to be free from original defects in material and workmanship for a period of one year (inside USA and Canada) from the date of start-up. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the defective parts without charge for labor or parts. If the product was not started-up by authorized Tripp Lite service, replacement parts will be provided but labor charges will apply based on published Tripp Lite Time and Material Rates. Tripp Lite will assign to you any warranties provided by the manufacturers of components of the Tripp Lite product. Tripp Lite makes no representations as to the extent of these warranties and assumes no responsibility for warranties of these components. Service under this Warranty can only be obtained by contacting: Tripp Lite Customer Service; 1111 W. 35th Street; Chicago IL 60609; (773) 869-1234.

THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, IMPROPER INSTALLATION, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction).

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

16

Image 16
Contents Warranty RegistrationImportant Safety Warnings Battery WarningsUPS Location Warnings UPS Connection WarningsFront Panel Control PanelBattery Access Panel cover removed Rear Panel Rear PanelInstallation Mounting Bracket InstallationUPS Input and Output Hardwire Connection UPS LocationInitial Battery Charging SELF-TESTINGOperation Normal Conditions Turning the UPS onLCD Display Select Button Operation Special ConditionsOperation on BYPASS-VOLTAGE OUT of Range Operation of Manual Bypass Switch Switching UPS to Bypass ModeSwitching UPS to Normal Mode Inverter on WarningsCommunications RS-232 InterfaceAS-400 Interface DRY Contact InterfaceRemote Emergency Power OFF EPO Do not Remove Battery SleeveBattery Packs are Heavy Check Battery Pack Voltage Before Completing InstallationInternal Battery Pack Wiring Diagram Adding or Replacing Internal Batteries Terminals Adding or Replacing Internal Batteries Service Warranty & Warranty RegistrationPhase UPS System Limited Warranty Warranty RegistrationModel SU20K3/3 SpecificationsModel SU20K3/3XR5 Model SU30K3/3 Model SU30K3/3XR5Manual del Propietario Advertencias de Seguridad Importantes Advertencias sobre la colocación y ubicación del UPSAdvertencias para la conexión del UPS Advertencias Sobre la BateríaPanel Frontal Panel DE ControlPanel Frontal continuación Panel DE Acceso a LA Bateria Tapa RemovidaPanel Trasero Panel TraseroInstalación Ubicación DEL UPSInstalacion DE LOS Soportes DE Montaje Conexion a TierraOperación Condiciones Normales Carga Inicial DE LA BateriaEncendiendo EL UPS Apagando EL UPSOperación Condiciones Normales continuación Operación Condiciones EspecialesBoton Select Seleccionar DE LA Pantalla LCD Operacion EN DERIVACION-VOLTAJE Fuera DE RangoOperación Condiciones Especiales continuación Comunicaciones Interfaz RS-232Interfaz AS-400 Interfaz DEL Contacto SecoComunicaciones continuación Añadiendo o Remplazando las Baterías InternasApagado DE Emergencia Remoto EPO ¡NO Remueva LA Cubierta Protectora DE LA BateriaDiagrama DEL Cableado DEL Modulo DE Baterias Internas Añadiendo o Remplazando las Baterías Internas continuaciónAñadiendo o Remplazando las Baterías Internas continuación Terminales ¡PELIGRO ¡OBSERVE LA Polaridad Correcta Garantía ServicioGarantía Limitada del Sistema UPS Trifásico Modelo SU20K3/3 EspecificacionesModelo SU20K3/3XR5 Modelo SU30K3/3 Especificaciones continuaciónModelo SU30K3/3XR5 Manuel du propriétaire Importantes consignes de sécurité Mises en garde relatives à la localisation de londuleurMises en garde relatives aux connexions de londuleur Mises en garde relatives aux connexions de léquipementPanneau DE Commande Panneau avantPanneau avant suite Panneau Daccès AUX Batteries carter enlevéPanneau arrière Panneau ArrièreIL Faut Installer Londuleur À Laide DE Brides DE Fixation Mises EN Garde Relatives À LA Localisation DE LonduleurConnexion DE Mise À LA Terre Sélection DU CâblageInstallation suite Fonctionnement Conditions normalesFonctionnement Conditions normales suite Fonctionnement Conditions spécialesBouton DE Sélection DE Lécran ACL Fonctionnement EN DÉRIVATION-TENSION Hors PlagCommuter Londuleur EN Mode Normal Fonctionnement Conditions spéciales suiteMises EN Garde Inverseur EN Marche Fonctionnement Pendant UN ArrêtInterface AS-400 Interface RS-232Interface Contact SEC Ajout et remplacement des batteries internes Arrêt Durgence Emergency Power OFF EPO À DistanceCommunications suite NE PAS Retirer LA Gaine DE BatterieAjout et remplacement des batteries internes suite Schéma DU Câblage Interne DUN Bloc DE BatterieAjout et remplacement des batteries internes suite Bornes Ajout et remplacement des batteries internes suite Garantie limitée de londuleur triphasé GarantieObserver LA Bonne Polarité Modèle SU20K3/3 SpécificationsModèle SU20K3/3XR5 Spécifications suite Modèle SU30K3/3 Modèle SU30K3/3XR5Th Street Chicago, IL 60609 USA 773