Panasonic EYFLA4A operating instructions Off, Initializing All Settings, Checking Tool Settings

Page 14

Radio signal range limitation function on/off setting (EYFLA4AR, EYFLA5AR, EYFLA5QR, EYFLA6PR)

1.Set the tool to configuration mode. (See page 11.)

2.Press the format button.

The control panel will begin flashing.

Display: The letter “F” flashes on and off.

Battery indication lamp: The upper and lower bars of the battery flash on and off.

Display

Battery indication lamp

3.Press the format button again.

Radio signal range limitation function on/off setting value will be displayed.

4.Press the and buttons to set radio signal range limitation function on/off.

 

Radio signal

 

 

Display

range limitation

 

Status

 

function mode

 

 

 

 

Tool is operational in the

C0

OFF

absence of communica-

tions with the Assembly

 

 

 

 

Qualifier.

 

 

 

Tool is

not operational

C1

ON

in the absence of com-

munications with the As-

 

 

 

 

sembly Qualifier.

Factory settings

Radio signal range limitation function setting: C0 (OFF)

NOTE:

For more information about how to register the tool and assembly qualifier, see the assembly qualifier instruction manual.

Initializing All Settings

Factory settings

Torque clutch setting: “F” (torque con- trol function off)

Interval setting: 0 (off)

This section explains how to revert all tool settings to their default values at the time of shipment from the factory.

The error display will be turned off.

1.Set the tool to configuration mode. (See page 11.)

2.Press the format button.

The control panel will begin flashing.

Display: The letter “F” flashes on and off.

Battery indication lamp: The upper and lower bars of the battery flash on and off.

Display

Battery indication lamp

3.Press the OK button to accept the select- ed setting.

The control panel will stop flashing and light up.

Checking Tool Settings

This section describes how to have the tool display current settings for approx- imately 3 seconds when the tool is stopped.

You cannot check tool settings when the control panel is turned off. First, engage the switch briefly to reactivate the display.

Checking the sung point detection setting

1.Press the torque set button.

Control panel display

Display: The torque set lights up.

Battery indication lamp: The upper and mid- dle bars of the battery flash on and off.

Checking the interval

1.Press the interval set button.

Control panel display

Display: The interval set lights up.

Battery indication lamp: The middle bar of the battery flashes on and off.

- 14 -

Image 14
Contents Model No EYFLA4A / EYFLA4AR ImportanteIndex Page Personal Safety Work Area SafetyElectrical Safety Power Tool Use and CareService III.ADDITIONAL Safety RulesBattery Tool Use and Care II. Intended USEAttaching or Removing Bit IV. AssemblySymbol Meaning Attaching Socket Pin typeAttaching Socket Pin-detent Attaching or Removing Bat­ tery PackInsert the battery Main Body Switch and Forward/Reverse Lever OperationWireless remote control range OperationControl Panel Forward Rotation Switch OperationReverse Rotation Switch Operation Tightening confirmation lampIndicator Battery status Battery indication lampAutomatic power-off function IndicatorSetting the tool to configuration mode Configuring the torque clutch settingEZFLA4 EZFLA5 Setting the snug point detection levelImportant Information Snug point detection level guidelines Tightening Torque Chart for Reference UseUsing the Interval Set OFF Initializing All SettingsChecking Tool Settings Display Likely cause Error DisplayDisplay Tool circuit Corrective actionBattery Charger Charging VI. MaintenanceBattery Pack For Appropriate Use of Bat­ tery Pack Before charging the bat­ teryEYFRZ01 VII. AccessoriesFederal Communications Commission Interference Statement Battery Charger not included with shipment VIII.SPECIFICATIONSBattery Pack not included with shipment EYFLA4 EYFLA5 EYFLA6 EYFMA1 PR,JRRadio Information Remote control not included with shipmentAssembly Qualifier not included with shipment Channel FrequenciesSécurité électrique Consignes DE SECU­Sécurité de la zone de travail Sécurité personnelleUtilisation et soins de l’outil méca­ nique Utilisation et soins de la batterie de l’outilIV. Montage II. Utilisation PrevueSupplementaires Fixation ou retrait d’une mèchePour fixer la douille goupille darrêt Pour fixer la douille Type à goujonPour retirer la douille Type à goujon Pour retirer la douille goupille darrêtInsérez la batterie FonctionnementFixation ou retrait de la bat­ terie autonome Utilisation du commutateur pour une rotation en sens normal Portée de la télécommande sans filCorps principal Lumière DEL Panneau de commandeTémoin de confirmation de serrage Témoin indicateur de la batterieEtat de la batterie Fonction de commande du couple de serrageFonction d’arrêt automatique IndicateurRéglage de l’outil dans le mode configuration Configuration du réglage de l’embrayage du couple de serrageRéglage du niveau de détection du point de pré-serrage Informations ImportantesGraphique du couple de serrage Pour référence Utilisation du réglage de l’intervalleInitialisation de tous les réglages DesactiveActive Vérification des réglages de l’outil Circuit de l’outilAction correctrice Affichage d’erreurAffichage Cause probable Chargeur de batterie Recharge VI. EntretienBatterie Avant de charger la batterieVII.ACCESSOIRES ID FCC O4O-EYFLA IC 8507A-EYFLAChargeur DE Batterie non inclue dans l’expédition VIII.CARACTERISTIQUES TechniquesBatterie Autonome non inclue dans l’expédition Informations sur la radio Télécommande non inclue dans l’expéditionVérificateur dassemblage non inclus dans lexpédition Fréquences des canauxSeguridad personal Seguridad del lugar de trabajoSeguridad eléctrica ¡ADVERTENCIA! Lea todas las instruccionesUso y cuidados de herramientas eléctricas Uso y cuidado de la herramienta a bateríaIV. Montaje II. USO PretendidoIII.REGLAS DE SEGURI­ DAD Adicionales Colocación o extracción de la brocaInstalación de cubo Pasador retenedor Instalación del cubo Tipo pasadorRemoción del cubo Tipo pasador Remueva el cubo Pasador retenedorInserción de la batería FuncionamientoColocación y extracción de la batería Cuerpo principal Rango de control remoto inalámbricoLuz LED Panel de controleLámpara de confirmación de apriete Lámpara indicadora de la bateríaIndicador Estado de la batería Función de apagado automáticoFunción de control de par de torsión IndicadorConfiguración del ajuste de embrague del par de torsión Ajuste de la herramienta al modo de con­ figuraciónAjuste del nivel de detección del punto de apriete exacto Información Importante Uso del juego de intervaloInicialización de todos los ajustes ApagadoEncendido Verificación de los ajustes de herramienta Acción correctiva Visualización de errorVisor Causa probable Cargador de la batería Carga VI. MantenimientoBloque de pilas Para un uso adecuado de la batería Antes de cargar la bateríaVII.ACCESORIOS Cargador DE Batería no se incluye con el embarque VIII.ESPECIFICACIONESBatería no se incluye con el embarque EYFB30Información de radio Control remoto no se incluye con el embarqueCualificador incorporado no se incluye en el embarque Frecuencias de canalEN, FR, ES