Checking tool circuits
1.Press the torque level button.
•Control panel display
Display: The torque set display lights up.
Battery indication lamp: The middle and lower bars of the battery flash on and off.
Display | Tool circuit |
H6 | EYFLA4 |
H7 | EYFLA5 |
H8 | EYFLA6 |
H9 | EYFMA1 |
NOTE:
•If you engage the switch while a setting is being displayed, the control panel will revert to the torque clutch setting dis- play.
CAUTION:
•The torque set display is not intended to be used to identify the type of drive component parts (hammer, etc.) used in a particular tool.
Error Display
In the event of a tool or battery pack malfunction, the control panel will display an error message. Please check the tool or battery pack as described in the following chart before having them
serviced.
Display
Likely cause
Setting error
Corrective action
The battery pack is too hot.
The tool is too hot to operate.
The contacts that connect the battery pack and tool are dirty.
The battery pack has not been properly inserted into the tool.
The pins on either the tool or battery pack have worn down.
Stop work and allow the battery pack to cool before resuming use of the tool.
Stop work and allow the tool to cool before resuming use.
Remove any dirt.
Insert the battery pack firmly into the tool.
Replace the battery pack.
Motor failure, etc.
Tool circuit malfunction, failure, etc.
The tool is unable to communi- cate with the Assembly Quali- fier while the radio signal range limitation function is on.
Stop using the tool immediately.
•Verify that the tool has been properly registered to the Assem- bly Qualifier.
•Verify that the Assembly Qualifi- er’s group setting has been con- figured correctly.
•Improve the reception state, for example by moving the Assem- bly Qualifier closer to the tool.
- 15 -