NOTE: Compressed air from oil lube air compressors will contain water­ condensation and oil mist. Several drains, traps and filters will be needed to supply air without water (including aerosols) or oil to spray equipment, air tools and accessories requiring filtered air. Always read the instruc­tions­ for the air tools and accessories being used.

Use pipe that is the same size as the air tank outlet. Piping that is too small will restrict the flow of air.

If piping is over 100' (30.5 m) long, use the next larger size.

Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.

A flexible coupling is recommended to be installed between the globe valve/ air discharge outlet and main air distribution line to allow for vibration.

A separate regulator is recommended to control the air pressure. Air pressure from the tank is usually to high for individual air driven tools.

DO NOT install lubricators between the tank and any spray equipment, air tool or accessory requiring oil-free filtered air.

Drain all traps, filters and dirt legs daily.

AIR FLOW

FEEDER LINES SLOPE

AIR FLOW

WITH AIR FLOW

 

MAIN DISTRIBUTION AIR LINES

 

 

 

 

Slope pipe in direction of air flow.

 

 

DRAIN

Water condensate flows along

 

AIR USAGE

 

LEGS

bottom of pipe to drain legs,

 

LINES

 

 

preventing it from entering feeder

 

 

 

lines.

 

 

 

 

DRAIN

 

 

 

 

 

 

 

 

 

 

VALVES

 

.01 MICRON

5 MICRON

 

FILTER /

 

 

FILTER

FILTER

 

MOISTURE

 

 

 

 

 

TRAP

 

 

 

 

DIRT

 

 

 

 

 

LEGS

 

 

SPRAY

 

 

 

 

REGULATOR

GUN

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN

 

LUBRICATOR

 

 

 

 

 

REGULATOR

 

 

VALVES

 

 

 

 

 

 

 

BALL

 

 

 

 

 

FILTER

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

TOOL

FILTER /

FOR BEST PERFORMANCE

FLEXIBLE

 

 

the distance between the

 

 

MOISTURE

compressor and the

COUPLING

 

 

TRAP

moisture trap should be as

 

 

GLOBE VALVE /

 

long as possible

 

 

 

 

 

AIR DISCHARGE

 

 

 

 

 

 

 

 

 

AIR

VALVE

DRAIN

 

 

 

 

TYPICAL

 

COMPRESSOR

VALVE

 

 

 

 

COMPRESSED AIR

 

 

 

DISTRIBUTION

 

 

 

 

SYSTEM

 

 

DRAIN

 

 

 

 

 

VALVE

 

RISK OF BURSTING. ALWAYS USE

 

 

 

 

METAL PIPING AND FITTINGS.

 

 

 

10 - ENG

Image 10
Contents C7501 Important Safety Instructions Safety Guidelines DefinitionsHazard What can happen How to prevent it Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessoriesTires To Grounding Instructions para Risk of Electrical Shock What can happen How to prevent itElectrical Grounding Failure to Risk from Flying ObjectsRisk of Unsafe Operation Risk from Moving Parts What can happen How to prevent itRisk of Injury from Lifting Glossary SpecificationsRisk from noise What can happen How to prevent it Duty CycleAssembly AccessoriesInstallation Voltage and Circuit Protection Wiring InstructionsAir Distribution System Typical Know Your Air Compressor OperationDescription of Operation How to Use Your Unit How to StopHow to Start Before Each Start-UpTo Check Safety Valve MaintenanceCustomer Responsibilities Checking To Drain TankOil Sight glass CAir Filter Inspection and Replacement Belt ReplacementInspect Air Lines and Fittings for Leaks Motor Pulley/Flywheel AlignmentAir Compressor Pump Intake and Exhaust Valves Air compressor Head Bolts TorquingService and Adjustments To Replace or Clean Check ValveService and Repairs StorageReplace or Clean Check Valve TroubleshootingProblem Cause Correction Do not drill into, weld or otherwiseRefer to Motor Overload Protection Maintenance section See Motor Pulley/FlywheelFull One Year Warranty Compressed Air DistributionNe posant aucun risque de Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Pourrait poser des risques deRisque Repiratoire Asphyxie Ce qui peut se produire Comment l’ÉviterRisque d’Éclatement Risque de choc Électrique Attachements et Accessoires Pneus Mise à la terre électrique leRisque associÉ aux PiÈces mobilesRisque DE Blessure EN Soulevant LE Produit Risque associÉ À utilisationRisque associÉ au bruit Lexique Modèle No C7501Accessoires Cycle DE ServiceAssemblage Ancrage du compresseur dair Directives de câblageTension et protection des circuits Système de distribution dairSystème DE Distribution Dair Typique Familiarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant chaque mise en marche Fermez le robinet à soupape/la sortie de décharge d’airResponsabilités du consommateur EntretienMise en marche Vérification de la soupape de sûreté Vidange du réservoirVérification Filtre à air Inspection et remplacementHuile ChangementRemplacement de la courroie Alignement de la poulie et du volant-moteurRéparations ET Réglages Boulons de la tête du compresseur serrageRemplacement ou nettoyage de la soupape Appliquez le solvant sur les filets duRangement ServiceEntretien ET Réparation Dépannage Problème Cause CorrectionRemarque Réglez la Du moteur sous UtilisationDu compresseur De la poulie et du volant Typique de distribution d’air sousGarantie complète d’un 1 an Instrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadPeligro Opere el compresor en un área Riesgo de explosión Anclaje en InstalaciónRiesgo de descarga eléctrica Elementos y accesoriosNeumáticos Instrucciones de ConexiónRiesgo DE superficies calientes Riesgo por piezas móvilesMucho Peso Riesgo de operación inseguraRiesgo DE Lesión POR Levantar Riesgo por ruidosCiclo DE Servicio EspecificacionesGlosario NO. DE ModeloEnsamblado AccesoriosInstalación Instrucciones para la conexión eléctrica Protección del voltaje y del circuitoSistema de distribución de aire DE Purga Sistema Típico DE Distribución DE Aire Conozca su compresor de aire OperaciónDescripción de operaciones Cómo utilizar su unidad Cómo detenerlaAntes de cada puesta en marcha Responsabilidades del cliente MantenimientoCómo poner en marcha Cómo drenar el tanque Cómo verificar la válvula de seguridadAceite Verificación Filtro de Aire Inspección y reemplazoCorrea Reemplazo CambioPolea y volante Alineación Tornillos del cabezal del compresor de aire. Torque Servicio Y AjustesPara reemplazar o limpiar la válvula de retención De la válvula en la posición cerrada Almacenaje ServicioGuía DE Diagnóstico DE Problemas Problema Causa CorrecciónConsulte Protector de Párrafo Filtro de Aire en laSobrecalentamiento del motor Haga inspeccionar por un técnico Párrafo Sistema típico de dis Polea/volante del motor enVer Verificacion del Aceite en Tribución de aire comprimidoIdentificación DEL Producto Sello o firma del Distribuidor ExcepcionesGarantía completa de un año Para Otras Localidades Page Page Highway 45 North Jackson, TN 888