Porter-Cable N028591, C7501 Maintenance, Customer Responsibilities, To Check Safety Valve

Page 14

MAINTENANCE

Customer Responsibilities

 

 

 

Before

Daily

Every

Every

Every

Every

Yearly

 

 

 

each

or

8

40

100

160

 

 

 

 

use

after

hours

hours

hours

hours

 

 

 

 

 

each

 

 

 

 

 

 

 

 

 

use

 

 

 

 

 

Check Safety Valve

 

 

 

 

 

 

Drain Tank

 

 

 

 

 

 

 

Oil Leaks

 

 

 

 

 

 

 

Check Pump Oil

 

 

 

 

 

 

Change Pump Oil

 

 

 

 

 

 

Unusual Noise and/or

 

 

 

 

 

 

Vibration

 

 

 

 

 

 

 

 

Air Filter

 

 

 

 

 

(1)

 

 

Drive Belt-Condition

 

 

 

 

 

 

Motor

Pulley/Flywheel

 

 

 

 

 

 

alignment

 

 

 

 

 

 

 

 

Air compressor pump

 

 

 

 

 

 

intake

and

exhaust

 

 

 

 

 

 

 

valves

 

 

 

 

 

 

 

 

 

Inspect air

lines and

 

 

 

 

 

 

fittings for leaks

 

 

 

 

 

 

 

Head Bolts - Check the

torques of

the head

bolts after the first five hours of operation.

1- more frequent in dusty or humid conditions

 

 

 

 

Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.

NOTE: See Operation section for the location of controls.

To Check Safety Valve

Risk of bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion.

Risk from flying objects. Always wear certified safety equip-

ment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.

Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

14 - ENG

Image 14
Contents C7501 Hazard Safety Guidelines DefinitionsImportant Safety Instructions What can happen How to prevent it Risk to Breathing AsphyxiationTires Attachments & accessoriesRisk of Bursting To Grounding Instructions para Risk of Electrical Shock What can happen How to prevent itElectrical Grounding Failure to Risk from Flying ObjectsRisk of Injury from Lifting Risk from Moving Parts What can happen How to prevent itRisk of Unsafe Operation Glossary SpecificationsRisk from noise What can happen How to prevent it Duty CycleInstallation AccessoriesAssembly Air Distribution System Wiring InstructionsVoltage and Circuit Protection Typical Description of Operation OperationKnow Your Air Compressor How to Use Your Unit How to StopHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve Checking To Drain TankOil Sight glass CAir Filter Inspection and Replacement Belt ReplacementInspect Air Lines and Fittings for Leaks Motor Pulley/Flywheel AlignmentAir Compressor Pump Intake and Exhaust Valves Air compressor Head Bolts TorquingService and Adjustments To Replace or Clean Check ValveService and Repairs StorageReplace or Clean Check Valve TroubleshootingProblem Cause Correction Do not drill into, weld or otherwiseRefer to Motor Overload Protection Maintenance section See Motor Pulley/FlywheelFull One Year Warranty Compressed Air DistributionNe posant aucun risque de Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Pourrait poser des risques deRisque Repiratoire Asphyxie Ce qui peut se produire Comment l’ÉviterRisque d’Éclatement Risque de choc Électrique Attachements et Accessoires Pneus Mise à la terre électrique leRisque associÉ aux PiÈces mobilesRisque associÉ au bruit Risque associÉ À utilisationRisque DE Blessure EN Soulevant LE Produit Lexique Modèle No C7501Assemblage Cycle DE ServiceAccessoires Ancrage du compresseur dair Directives de câblageTension et protection des circuits Système de distribution dairSystème DE Distribution Dair Typique Description du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Utilisation de lappareil Arrêt de lappareilAvant chaque mise en marche Fermez le robinet à soupape/la sortie de décharge d’airMise en marche EntretienResponsabilités du consommateur Vérification de la soupape de sûreté Vidange du réservoirVérification Filtre à air Inspection et remplacementHuile ChangementRemplacement de la courroie Alignement de la poulie et du volant-moteurRéparations ET Réglages Boulons de la tête du compresseur serrageRemplacement ou nettoyage de la soupape Appliquez le solvant sur les filets duEntretien ET Réparation ServiceRangement Dépannage Problème Cause CorrectionRemarque Réglez la Du moteur sous UtilisationDu compresseur De la poulie et du volant Typique de distribution d’air sousGarantie complète d’un 1 an Peligro Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Opere el compresor en un área Riesgo de explosión Anclaje en InstalaciónRiesgo de descarga eléctrica Elementos y accesoriosNeumáticos Instrucciones de ConexiónRiesgo DE superficies calientes Riesgo por piezas móvilesMucho Peso Riesgo de operación inseguraRiesgo DE Lesión POR Levantar Riesgo por ruidosCiclo DE Servicio EspecificacionesGlosario NO. DE ModeloInstalación AccesoriosEnsamblado Instrucciones para la conexión eléctrica Protección del voltaje y del circuitoSistema de distribución de aire DE Purga Sistema Típico DE Distribución DE Aire Descripción de operaciones OperaciónConozca su compresor de aire Cómo utilizar su unidad Cómo detenerlaAntes de cada puesta en marcha Cómo poner en marcha MantenimientoResponsabilidades del cliente Aceite Cómo verificar la válvula de seguridadCómo drenar el tanque Verificación Filtro de Aire Inspección y reemplazoCorrea Reemplazo CambioPolea y volante Alineación Para reemplazar o limpiar la válvula de retención Servicio Y AjustesTornillos del cabezal del compresor de aire. Torque De la válvula en la posición cerrada Almacenaje ServicioGuía DE Diagnóstico DE Problemas Problema Causa CorrecciónSobrecalentamiento del motor Párrafo Filtro de Aire en laConsulte Protector de Haga inspeccionar por un técnico Párrafo Sistema típico de dis Polea/volante del motor enVer Verificacion del Aceite en Tribución de aire comprimidoIdentificación DEL Producto Sello o firma del Distribuidor ExcepcionesGarantía completa de un año Para Otras Localidades Page Page Highway 45 North Jackson, TN 888