MAINTENANCE
Customer Responsibilities
|
|
| Before | Daily | Every | Every | Every | Every | Yearly |
|
|
| each | or | 8 | 40 | 100 | 160 |
|
|
|
| use | after | hours | hours | hours | hours |
|
|
|
|
| each |
|
|
|
|
|
|
|
|
| use |
|
|
|
|
|
Check Safety Valve | • |
|
|
|
|
|
| ||
Drain Tank |
|
| • |
|
|
|
|
| |
Oil Leaks |
|
|
| • |
|
|
|
| |
Check Pump Oil |
|
| • |
|
|
|
| ||
Change Pump Oil |
|
|
|
|
| • |
| ||
Unusual Noise and/or |
|
| • |
|
|
|
| ||
Vibration |
|
|
|
|
|
|
|
| |
Air Filter |
|
|
|
|
| • (1) |
|
| |
Drive |
|
|
| • |
|
|
| ||
Motor | Pulley/Flywheel |
|
|
|
| • |
|
| |
alignment |
|
|
|
|
|
|
|
| |
Air compressor pump |
|
|
|
|
|
| • | ||
intake | and | exhaust |
|
|
|
|
|
|
|
valves |
|
|
|
|
|
|
|
|
|
Inspect air | lines and | • |
|
|
|
|
|
| |
fittings for leaks |
|
|
|
|
|
|
| ||
Head Bolts - Check the | torques of | the head | bolts after the first five hours of operation. | ||||||
1- more frequent in dusty or humid conditions |
|
|
|
|
Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.
NOTE: See Operation section for the location of controls.
To Check Safety Valve
Risk of bursting. If the safety valve does not work properly,
Risk from flying objects. Always wear certified safety equip-
ment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
14 - ENG