Porter-Cable N028591, C7501 Risk from Moving Parts What can happen How to prevent it

Page 6

HAZARD

Risk from Moving Parts

 

 

 

What can happen

How to prevent it

 

• Moving parts such as the pulley,

• Never operate the compres-

 

flywheel, and belt can cause seri-

sor with guards or covers which

 

ous injury if they come into con-

are damaged or removed.

 

tact with you or your clothing.

• Keep your hair, clothing, and

 

 

 

 

 

 

 

 

 

 

 

gloves away from moving parts.

 

 

 

 

 

 

 

 

 

 

 

Loose clothes, jewelry, or long hair

 

 

 

 

 

 

 

 

 

 

 

can be caught in moving parts.

 

 

 

 

 

 

 

 

 

 

 

• Air vents may cover moving parts

 

 

 

 

 

 

 

 

 

 

 

and should be avoided as well.

 

 

 

 

 

 

 

 

 

 

 

 

 

• Attempting to operate compressor

• Any repairs required on this product

 

with damaged or missing parts or

should be performed by autho-

 

attempting to repair compressor

rized service center personnel.

 

with protective shrouds removed

 

 

can expose you to moving parts

 

 

and can result in serious injury.

 

 

 

 

 

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Risk of Unsafe Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What can happen

How to prevent it

 

• Unsafe oper­a­tion­ of your

• Review and understand all instruc-

 

compressor could lead to seri­ous­

tions and warnings in this manual.

 

inju­ry­ or death to you or others.

• Become­ famil­iar­ with the operation­

 

 

 

 

 

 

 

 

 

 

 

and controls­ of the air compressor.

 

 

 

 

 

 

 

 

 

 

 

• Keep operating area clear of all

 

 

 

 

 

 

 

 

 

 

 

persons, pets, and obstacles.

 

 

 

 

 

 

 

 

 

 

 

• Keep children­ away from the

 

 

 

 

 

 

 

 

 

 

 

air compressor at all times.

 

 

 

 

 

 

 

 

 

 

 

• Do not operate the product

 

 

 

 

 

 

 

 

 

 

 

when fatigued or under the

 

 

 

 

 

 

 

 

 

 

 

influence of alcohol or drugs.

 

 

 

 

 

 

 

 

 

 

 

Stay alert at all times.

 

 

 

 

 

 

 

 

 

 

 

• Never defeat the safety fea­

 

 

 

 

 

 

 

 

 

 

 

tures of this product­.

 

 

 

 

 

 

 

 

 

 

 

• Equip area of operation

 

 

 

 

 

 

 

 

 

 

 

with a fire extinguisher.

 

 

 

 

 

 

 

 

 

 

 

• Do not oper­ate­ machine with miss-

 

 

 

 

 

 

 

 

 

 

 

ing, broken, or unau­tho­rized­ parts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF INJURY FROM LIFTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What can happen

How to prevent it

 

 

 

 

 

 

 

 

 

 

 

 

 

• Serious injury can result

• The compressor is too heavy to be

 

from attempting to lift

lifted by one person. Obtain assis-

 

too heavy an object.

tance from others before lifting.

 

 

 

 

 

 

 

 

 

 

 

 

6 - ENG

Image 6
Contents C7501 Safety Guidelines Definitions Important Safety InstructionsHazard What can happen How to prevent it Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingTires To Grounding Instructions para Risk of Electrical Shock What can happen How to prevent itElectrical Grounding Failure to Risk from Flying ObjectsRisk from Moving Parts What can happen How to prevent it Risk of Unsafe OperationRisk of Injury from Lifting Glossary SpecificationsRisk from noise What can happen How to prevent it Duty CycleAccessories AssemblyInstallation Wiring Instructions Voltage and Circuit ProtectionAir Distribution System Typical Operation Know Your Air CompressorDescription of Operation How to Use Your Unit How to StopHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities Checking To Drain TankOil Sight glass CAir Filter Inspection and Replacement Belt ReplacementInspect Air Lines and Fittings for Leaks Motor Pulley/Flywheel AlignmentAir Compressor Pump Intake and Exhaust Valves Air compressor Head Bolts TorquingService and Adjustments To Replace or Clean Check ValveService and Repairs StorageReplace or Clean Check Valve TroubleshootingProblem Cause Correction Do not drill into, weld or otherwiseRefer to Motor Overload Protection Maintenance section See Motor Pulley/FlywheelFull One Year Warranty Compressed Air DistributionNe posant aucun risque de Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Pourrait poser des risques deRisque Repiratoire Asphyxie Ce qui peut se produire Comment l’ÉviterRisque d’Éclatement Risque de choc Électrique Attachements et Accessoires Pneus Mise à la terre électrique leRisque associÉ aux PiÈces mobilesRisque associÉ À utilisation Risque DE Blessure EN Soulevant LE ProduitRisque associÉ au bruit Lexique Modèle No C7501Cycle DE Service AccessoiresAssemblage Ancrage du compresseur dair Directives de câblageTension et protection des circuits Système de distribution dairSystème DE Distribution Dair Typique Utilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant chaque mise en marche Fermez le robinet à soupape/la sortie de décharge d’airEntretien Responsabilités du consommateurMise en marche Vérification de la soupape de sûreté Vidange du réservoirVérification Filtre à air Inspection et remplacementHuile ChangementRemplacement de la courroie Alignement de la poulie et du volant-moteurRéparations ET Réglages Boulons de la tête du compresseur serrageRemplacement ou nettoyage de la soupape Appliquez le solvant sur les filets duService RangementEntretien ET Réparation Dépannage Problème Cause CorrectionRemarque Réglez la Du moteur sous UtilisationDu compresseur De la poulie et du volant Typique de distribution d’air sousGarantie complète d’un 1 an Definiciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadPeligro Opere el compresor en un área Riesgo de explosión Anclaje en InstalaciónRiesgo de descarga eléctrica Elementos y accesoriosNeumáticos Instrucciones de ConexiónRiesgo DE superficies calientes Riesgo por piezas móvilesMucho Peso Riesgo de operación inseguraRiesgo DE Lesión POR Levantar Riesgo por ruidosCiclo DE Servicio EspecificacionesGlosario NO. DE ModeloAccesorios EnsambladoInstalación Instrucciones para la conexión eléctrica Protección del voltaje y del circuitoSistema de distribución de aire DE Purga Sistema Típico DE Distribución DE Aire Operación Conozca su compresor de aireDescripción de operaciones Cómo utilizar su unidad Cómo detenerlaAntes de cada puesta en marcha Mantenimiento Responsabilidades del clienteCómo poner en marcha Cómo verificar la válvula de seguridad Cómo drenar el tanqueAceite Verificación Filtro de Aire Inspección y reemplazoCorrea Reemplazo CambioPolea y volante Alineación Servicio Y Ajustes Tornillos del cabezal del compresor de aire. TorquePara reemplazar o limpiar la válvula de retención De la válvula en la posición cerrada Almacenaje ServicioGuía DE Diagnóstico DE Problemas Problema Causa CorrecciónPárrafo Filtro de Aire en la Consulte Protector deSobrecalentamiento del motor Haga inspeccionar por un técnico Párrafo Sistema típico de dis Polea/volante del motor enVer Verificacion del Aceite en Tribución de aire comprimidoIdentificación DEL Producto Sello o firma del Distribuidor ExcepcionesGarantía completa de un año Para Otras Localidades Page Page Highway 45 North Jackson, TN 888