Porter-Cable C7501, N028591 instruction manual Refer to Motor Overload Protection

Page 21

PROBLEM

CAUSE

CORRECTION

Compressor is

Prolonged excessive

Decrease amount of air usage.

not supplying

use of air.

 

enough air

Compressor is not

Check the accessory air

to operate

large enough for

requirement. If it is higher than

accessories

air requirement.

the SCFM or pressure supplied

 

 

by your air compressor, you

 

 

need a larger compressor.

 

Hole in hose.

Check and replace if required.

 

 

 

 

Check valve restricted.

Remove and clean, or replace.

 

Air leaks.

Tighten fittings.

 

Restricted air intake filter.

Clean or replace air intake filter. Do not

 

 

operate the air compressor with the

 

 

filter removed. Refer to the Air Filter

 

 

paragraph in the Maintenance section.

 

Loose belt.

Loosen wingnut and then

 

 

tighten wingnut until it contacts

 

 

the washer, plus one turn.

Restricted

Dirty air filter.

Clean or replace. See Air Filter

air intake

 

paragraph in the Maintenance section.

Motor will

Motor overload

Refer to Motor Overload Protection

not run

protection switch

under Operation. If motor overload

 

has tripped.

protection trips frequently, contact

 

 

a Trained Service Technician

 

Tank pressure exceeds

Motor will start automatically when

 

pressure switch

tank pressure drops below "cut-

 

"cut-in" pressure.

in" pressure of pressure switch.

 

Check valve stuck open.

Remove and clean, or replace.

 

Loose electrical

Check wiring connection inside

 

connections.

pressure switch and terminal box area.

 

Possible defective motor

Have checked by a Trained

 

or starting capacitor.

Service Technician.

 

Paint spray on internal

Have checked by a Trained Service

 

motor parts.

Technician. Do not operate the

 

 

compressor in the paint spray area.

 

 

See flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch to

 

unloaded head pressure.

the "Off" position; if the valve

 

 

does not open, replace switch.

Motor will not

Fuse blown, circuit

1. Check fuse box for blown fuse

run (continued)

breaker tripped.

and replace as necessary. Reset

 

 

circuit breaker. Do not use a fuse

 

 

or circuit breaker with higher

 

 

rating than that specified for

 

 

your particular branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay fuse.

 

 

3. Check for low voltage conditions

 

 

and/or proper extension cord.

 

 

4. Disconnect the other electrical

 

 

appliances from circuit or

 

 

operate the compressor on

 

 

its own branch circuit.

21 - ENG

Image 21
Contents C7501 Safety Guidelines Definitions Important Safety InstructionsHazard Risk to Breathing Asphyxiation What can happen How to prevent itAttachments & accessories Risk of BurstingTires Electrical Grounding Failure to Risk of Electrical Shock What can happen How to prevent itTo Grounding Instructions para Risk from Flying ObjectsRisk from Moving Parts What can happen How to prevent it Risk of Unsafe OperationRisk of Injury from Lifting Risk from noise What can happen How to prevent it SpecificationsGlossary Duty CycleAccessories AssemblyInstallation Wiring Instructions Voltage and Circuit ProtectionAir Distribution System Typical Operation Know Your Air CompressorDescription of Operation How to Stop How to Use Your UnitBefore Each Start-Up How to StartMaintenance To Check Safety ValveCustomer Responsibilities Oil To Drain TankChecking Sight glass CBelt Replacement Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves Motor Pulley/Flywheel AlignmentInspect Air Lines and Fittings for Leaks Air compressor Head Bolts TorquingTo Replace or Clean Check Valve Service and AdjustmentsStorage Service and RepairsProblem Cause Correction TroubleshootingReplace or Clean Check Valve Do not drill into, weld or otherwiseRefer to Motor Overload Protection See Motor Pulley/Flywheel Maintenance sectionCompressed Air Distribution Full One Year WarrantyConsignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsNe posant aucun risque de Pourrait poser des risques deCe qui peut se produire Comment l’Éviter Risque Repiratoire AsphyxieRisque d’Éclatement Pneus Attachements et Accessoires Risque de choc Électrique Mise à la terre électrique lePiÈces mobiles Risque associÉ auxRisque associÉ À utilisation Risque DE Blessure EN Soulevant LE ProduitRisque associÉ au bruit Modèle No C7501 LexiqueCycle DE Service AccessoiresAssemblage Directives de câblage Ancrage du compresseur dairSystème de distribution dair Tension et protection des circuitsSystème DE Distribution Dair Typique Utilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Arrêt de lappareil Utilisation de lappareilFermez le robinet à soupape/la sortie de décharge d’air Avant chaque mise en marcheEntretien Responsabilités du consommateurMise en marche Vidange du réservoir Vérification de la soupape de sûretéHuile Filtre à air Inspection et remplacementVérification ChangementAlignement de la poulie et du volant-moteur Remplacement de la courroieBoulons de la tête du compresseur serrage Réparations ET RéglagesAppliquez le solvant sur les filets du Remplacement ou nettoyage de la soupapeService RangementEntretien ET Réparation Problème Cause Correction DépannageDu moteur sous Utilisation Remarque Réglez laDu compresseur Typique de distribution d’air sous De la poulie et du volantGarantie complète d’un 1 an Definiciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadPeligro Opere el compresor en un área Anclaje en Instalación Riesgo de explosiónNeumáticos Elementos y accesoriosRiesgo de descarga eléctrica Instrucciones de ConexiónRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Lesión POR Levantar Riesgo de operación inseguraMucho Peso Riesgo por ruidosGlosario EspecificacionesCiclo DE Servicio NO. DE ModeloAccesorios EnsambladoInstalación Protección del voltaje y del circuito Instrucciones para la conexión eléctricaSistema de distribución de aire DE Purga Sistema Típico DE Distribución DE Aire Operación Conozca su compresor de aireDescripción de operaciones Cómo detenerla Cómo utilizar su unidadAntes de cada puesta en marcha Mantenimiento Responsabilidades del clienteCómo poner en marcha Cómo verificar la válvula de seguridad Cómo drenar el tanqueAceite Correa Reemplazo Filtro de Aire Inspección y reemplazoVerificación CambioPolea y volante Alineación Servicio Y Ajustes Tornillos del cabezal del compresor de aire. TorquePara reemplazar o limpiar la válvula de retención De la válvula en la posición cerrada Servicio AlmacenajeProblema Causa Corrección Guía DE Diagnóstico DE ProblemasPárrafo Filtro de Aire en la Consulte Protector deSobrecalentamiento del motor Haga inspeccionar por un técnico Ver Verificacion del Aceite en Polea/volante del motor enPárrafo Sistema típico de dis Tribución de aire comprimidoExcepciones Identificación DEL Producto Sello o firma del DistribuidorGarantía completa de un año Para Otras Localidades Page Page Highway 45 North Jackson, TN 888