Dukane iQ Series user manual AC Power Requirements

Page 66

iQSeries, Ultrasonic Hand Held Systems User’s Manual

AC Power Requirements

 

System

 

 

Overload

 

North America/

Operating

Generator

Probe

Power

Input AC Power Requirements

Model

Japan

Frequency

Model Number

Part Number

Rating

Nominal AC Volt

Number

AC Outlet Rating

 

 

 

(Watts)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20kHz

HP 2.61-P

20HP060-1E

41PG20S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.61-H

20HP060-1E

41HP20S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.62-P

20HP060-2E

41PG20S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.62-H

20HP060-2E

41HP20S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

30kHz

HP 3.61-H

30HP060-1E

41HP30S

600

100-120 VAC, 50/60 Hz @ 9.0 Amps

15.0 Amps

 

 

 

 

 

30kHz

HP 3.62-H

30HP060-2E

41HP30S

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

 

40kHz

HP 4.61-P

40HP060-1E

41PG40S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.61-H

40HP060-1E

41HP40S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.62-P

40HP060-2E

41PG40S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.62-H

40HP060-2E

41HP40S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

Table 9- IAC Power Requirements

Page  60

Dukane Manual Part No. 403-577-01

Image 66
Contents User’s Manual Copyright Revision History RevisionSummary Date This page intentionally left blank Contents This page intentionally left blank Section IntroductionThis page intentionally left blank General User Information Read This Manual FirstDrawings and Tables Generator Key FeaturesSystem Overview Hand ProbesHealth and Safety This page intentionally left blank General Considerations Plastics Health NoticeElectrical Safety Domestic Power GroundingInternational Power Grounding Installation Unpacking Placing RFI Grounding Connnecting CablesThis page intentionally left blank Unpacking PlacingRFI Grounding Connecting Cables Quick Start Guide AC Power InletPower Cords 200/240 Volt SystemsUltrasound Output System Outputs Optional Connections Pin 1 End of Weld AlarmPin 2 Any Fault Alarm Pin 0V Output CommonControls This page intentionally left blank Power Switch/Circuit Breaker Front Panel OverviewControl Keys + and Keys Power Bar GraphArrow Keys System LCD DisplayStart-up Sequence Starting a Weld CycleStopping a Weld Cycle LCD Display Overview Manual WeldProcess Control Settings Setup MaintenanceThis page intentionally left blank Process Controller Settings Select the Welding ModeNavigating Through the Modes Navigate to Time ModeNavigating to Manual Mode Time keyNavigate to Energy Mode KeyAmplitude Adjustment HoldSystem Information Hardware Settings, Advanced Hardware SettingsSystem Information Advanced Settings Free Run Frequency40 % Setup Maintenance IntroductionNavigating Saving the Current Setup Selecting a SetupDeleting a Setup This page intentionally left blank Probes and Probe Stacks This page intentionally left blank Ultrasonic Probe Overview Operating NotesCompressed Air Fitting In continuous duty Theory of Operation Ultrasonic Horn Stack Assembly Attaching a Replaceable Tip to a HornAttaching the Mounting Stud to a Horn or a Booster 5Stack Assembly Procedure In-lb Ft-lb KHz Stack Disassembly Removing the Mounting Stud from a Horn or Booster How to Tell the Booster Input End from the Output Booster NotesTroubleshooting This page intentionally left blank System Power Output Level No Ultrasonic OutputWelding Problems Weak WeldsInconsistent Welds Pop-up Fault Status Screens Generator Fault Status Screens Manual ModeProcess Fault Status Screens Time and Energy Modes Options This page intentionally left blank Foot Switch Kit Part No IQ Hand Probe OptionsBuzzer Kit Part No This page intentionally left blank Specifications This page intentionally left blank 1Generator Outline Drawing 2Probes Outline Drawings and Dimensions Weights Operating EnvironmentAC Power Requirements Regulatory Agency Compliance CE MarkingThis page intentionally left blank Outputs Interface This page intentionally left blank IQ Hand Probe Generator Rear Panel Detail This page intentionally left blank Contacting Dukane This page intentionally left blank Intelligent Assembly Solutions Contacting DukaneIdentify Equipment This page intentionally left blank Appendices This page intentionally left blank List of Figures Front PanelList of Tables DescriptionDukane ISO Part No - 577- 01