Section 7 – Troubleshooting
Pop-up Fault Status Screens
Generator Fault Status Screens - Manual Mode
Status Text Displayed | System Status or Fault Explanation | |
Generator Fault | An Average Overload fault tripped. | |
Output power exceeded rated wattage. | ||
| ||
Average Overload | Lower the welding pressure or amplitude. | |
| Fault will reset when next weld cycle starts. | |
Generator Fault | A Positive Peak Overload fault tripped. | |
Peak IGBT transistor current exceeded. | ||
Peak Overload | Caused by a severe frequency | |
| Fault will reset when next weld cycle starts. | |
Generator Fault | Resonant frequency lock not found, or lost. | |
Check for a defective stack component. | ||
| ||
Frequency Lock Lost | Check for stack coupling to the fixture. | |
| Fault will reset when next weld cycle starts. | |
Generator Fault | System Overtemperature fault detected. | |
Fault will reset when system cools down. | ||
Over Temperature |
| |
Generator Fault | Internal communications error. | |
Turn generator power off and back on. | ||
Cycle Power | ||
Call Dukane service if the fault persists. | ||
| ||
Table |
Continued