LVC "ON/OFF" SWITCH
Mount the LVC switch bracket (C) Fig. 6 (removed earlier) to the inside of the hole (D) on the left front edge of the extension wing. Use the hardware that was also removed.
NOTE: If you have a magnetic starter switch, see the “MAGNETIC STARTER 'ON/OFF' SWITCH” instructions.
MAGNETIC STARTER "ON/OFF" SWITCH
D
C
A
Fig. 6
1.Loosely attach the switch and bracket (A) Fig. 7 to the inside front lip of extension wing. Insert a
2.Attach the side of the switch bracket (A) Fig. 13 to the inside of the extension wing at the front of the saw using the
D
F
G
E
A
C
D
A
Fig. 7
Fig. 8
GUARD AND SPLITTER ASSEMBLY
Disconnect the machine from the power source!
1.Remove the table insert (Fig. 9).
2.Turn the locking handle on the front of the saw counter- clockwise.
3.Turn the wheel on the front of the saw clockwise as far as it will go.
4.Remove the saw blade from the machine by following the instructions in “CHANGING THE SAW BLADE”.
NOTE: The inside splitter mounting bracket (A) Fig. 10 was attached to the inside of the saw at the factory. To check the alignment, remove the screw and fastener plate
(C)Fig. 10. Use a straight edge (D) Fig. 11 to see if the splitter bracket (A) is aligned with the inside blade flange
(B).Check both the top and bottom of the bracket (A) with the top and bottom of the flange (B).
C
A
|
| B |
Fig. 10 |
| |
|
| |
|
|
|
Fig. 9
A
B
D
Fig. 11
10