Graco 3A0868G important safety instructions Electrical, Power Connection non-IS units only

Page 18

Installation

Electrical

Power Connection (non-IS units only)

All electrical wiring must be completed by a qualified electrician and comply with all local codes and regulations.

Enclose all cables routed in the spray booth and high traffic areas in conduit to prevent damage from paint, solvent, and traffic.

The ProMix 2KE operates with 85-250 VAC, 50/60 Hz input power, with a maximum of 2 amp current draw. The power supply circuit must be protected with a 15 amp maximum circuit breaker.

Not included with system:

Power supply cord compatible to your local power configuration. Wire gauge size must be 8-14 AWG.

The input power access port is 22.4 mm (0.88 in.) in diameter. It accepts a bulkhead strain relief fitting or conduit.

1.Verify that electrical power at the main panel is shut off. Open Control Box cover.

2.Connect electrical cord to the terminal block as shown in FIG. 6.

3.Close the Control Box. Restore power.

4.Follow instructions in Grounding, page 19.

Line

Ground

Neutral

ti16391a

FIG. 6. Control Box Electrical Connection

TERMINAL

BLOCK

L N GRND

 

POWER

L GRND N

SUPPLY

LINE POWER

 

FILTER

 

LN

2A1A

SWITCH

ROCKER

21

FIG. 7. Electrical Schematic

18

3A0868G

Image 18
Contents ProMix 2KE Contents Models USBSeries Ratio Pumps Psi MPa, bar Port Approvals Related Manuals ModelsManual Description Fire and Explosion Hazard Special Conditions for Safe USEElectric Shock Hazard Intrinsic Safety Skin Injection HazardToxic Fluid or Fumes Hazard Equipment Misuse HazardMoving Parts Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Usage InstallationOverview Component Identification and DefinitionIntrinsically Safe Installation Requirements Hazardous Location InstallationNon-Hazardous Locations Requirements Display ModuleAir Supply Air regulator and bleed-type shutoff valveFluid Supply Air ConnectionsFluid Connections SVA DVA KeySVB DVB Tubing Chart and Diagrams Used only on is modelsGFB1-A ATOM-1 ATOM-2 Power Connection non-IS units only ElectricalGrounding Grounding IG . Display Module Display ModuleDisplay Key FunctionIcon Key Troubleshooting Run ModeSetup Mode Screen SummaryScreen User Input Range/Options Default Ranges for User InputsHome ErrorsPump Control RunSet-Up Home Password Configure RecipeMaintenance Calibration Set-Up HomeSystem Outputs Set-Up Home System Inputs System OutputsMembrane Test Basic Operation Power OnInitial System Setup Pre-Operation TasksPrime the System Pump Calibration Calibrate the pumpBration 1 and 2 Screens 22 and 23, SprayingPurging Purging Mixed Material Purging Fluid Supply SystemPurging Mixed Material Purging Fluid Supply SystemSolenoid Valves in Control Box Lock Mode Pressure Relief ProcedureValve Settings ShutdownUSB Logs Error LogUse of Optional USB Module Job LogSetup Sample Error LogDownload Procedure Recommended USB Flash DrivesUSB Port Run Home Screen Run Mode DetailsRun Mix Spray Screen Run Mix Batch ScreenRun Log Errors Screens Run Mix Totals ScreenRun Job Number Screen Run Pump Control Screen Run Pump Control ScreenSetup Mode Details Password ScreenSetup Home Screen Configure 1-4 Screens Confirm Change of System TypeConfigure 3 Screen 20 and Configure 4 Screen Recipe 1-1 Screen Recipe 1-2 ScreenRecommended Maintenance Maintenance 1-3 ScreensMaintenance Recommendations Component FrequencyTroubleshooting Screens Calibration 1 and 2 Screens 22Troubleshooting System Inputs Screen Troubleshooting System Outputs ScreenMembrane Test Screen Dynamic Dosing General Operating Cycle, Dynamic DosingSelect a Component B Restrictor Size Pressure Too High Pressure Too Low Pressure B Pressure B Control Range with Properly Sized RestrictorTo Clear Error and Restart System ErrorsSystem Alarms Air Flow Switch AFS FunctionSystem Idle Warning Idle Error Codes System Alarm/Advisory/Record CodesCommunication Error Alarm TroubleshootingAlarm and Description Cause Solution USB Communication ErrorEQU2 Pneumatic Schematic, page 66 or Alarm and Description Cause Solution SFA1 or SFB1PreMix Error PreFill ErrorRatio Low Error Already about equal, verify that comQDA1 QDB1Leak Error Alarm and Description Cause Solution QTA1 or QTB1Dose Time Error Linear Sensor ErrorPark Error Alarm and Description Cause Solution DDA1 or DDB1Diving/Cavitation Error Stall Up ErrorDynamic Dosing Restrictor Selection Graphs ExampleRestrictor Sizes Size Code Orifice Size Differential Pressure between a and B Flow Rate cc/min Detail View500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 Schematics System Pneumatic SchematicPneumatic Schematic Non-Hazardous LocationAIR Flow Switch SIG Hazardous Location Electrical Schematic Fluid J4CONTROL ModulePower Supply Non-Hazardous Electrical Schematic Dimensions and Mounting Merkur Merkur BellowsOn-ratio accuracy Technical DataProMix 2KE Metric Noise levelGraco Standard Warranty Graco Information