Graco 3A0868G important safety instructions IG . Display Module, Key Function

Page 21

Display Module

Display Module

Screen number

Error code

Potlife state

Active recipe

 

 

 

Ratio

 

 

Operation mode; see

 

 

 

LCD display

 

 

page 22 for key

 

 

 

Potlife timers

 

 

Navigation keys

 

 

 

 

 

 

Flow rate

Soft keys

 

 

Enter key

Navigation keys

 

 

 

Standby key

 

 

Error Reset

 

 

key

Setup key

 

ti16319a

 

FIG. 10. Display Module

 

 

 

Display

Shows graphical and text information related to setup and spray operations. The screen backlight is factory set to remain on. The user may set a number of minutes the screen can be inactive before the backlight dims. See Configure 3 (Screen 20), page 44. Press any key to restore.

NOTE: The Display Module and bracket can be removed from the cover of the electrical box and mounted remotely, if preferred.

Keys are used to input numerical data, enter setup screens, navigate within a screen, scroll through screens, and select setup values.

NOTICE

To prevent damage to the soft key buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.

Key

Function

Setup: Press to enter or exit Setup mode.

Enter: Press to choose a field to update, to make a selection, or to save a selection or value.

Left/Right Arrows: Use to move from screen to screen.

Up/Down Arrows: Use to move among fields on a screen, items on a dropdown menu, or digits in a settable field.

Error Reset: Use to clear alarm so cause can be fixed. Also use to cancel a data entry field.

Standby: Stops the current operation and puts the system into standby.

Soft keys: Press to select the specific screen or operation shown on the display directly above each key.

3A0868G

21

Image 21
Contents ProMix 2KE Contents Models USBSeries Ratio Pumps Psi MPa, bar Port Approvals Related Manuals ModelsManual Description Fire and Explosion Hazard Special Conditions for Safe USEElectric Shock Hazard Skin Injection Hazard Intrinsic SafetyMoving Parts Hazard Equipment Misuse HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Overview InstallationUsage Component Identification and DefinitionHazardous Location Installation Intrinsically Safe Installation RequirementsNon-Hazardous Locations Air Supply Display ModuleRequirements Air regulator and bleed-type shutoff valveFluid Supply Air ConnectionsFluid Connections SVA DVA KeySVB DVB Used only on is models Tubing Chart and DiagramsGFB1-A ATOM-1 ATOM-2 Electrical Power Connection non-IS units onlyGrounding Grounding Display Display ModuleIG . Display Module Key FunctionIcon Key Setup Mode Run ModeTroubleshooting Screen SummaryRanges for User Inputs Screen User Input Range/Options DefaultPump Control ErrorsHome RunRecipe Set-Up Home Password ConfigureCalibration Set-Up Home MaintenanceSystem Outputs Set-Up Home System Inputs System OutputsMembrane Test Initial System Setup Power OnBasic Operation Pre-Operation TasksPrime the System Calibrate the pump Pump CalibrationPurging SprayingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Fluid Supply System Purging Mixed MaterialSolenoid Valves in Control Box Valve Settings Pressure Relief ProcedureLock Mode ShutdownUse of Optional USB Module Error LogUSB Logs Job LogSample Error Log SetupDownload Procedure Recommended USB Flash DrivesUSB Port Run Mix Spray Screen Run Mode DetailsRun Home Screen Run Mix Batch ScreenRun Log Errors Screens Run Mix Totals ScreenRun Job Number Screen Run Pump Control Screen Run Pump Control ScreenSetup Mode Details Password ScreenSetup Home Screen Confirm Change of System Type Configure 1-4 ScreensRecipe 1-1 Screen Recipe 1-2 Screen Configure 3 Screen 20 and Configure 4 ScreenMaintenance Recommendations Maintenance 1-3 ScreensRecommended Maintenance Component FrequencyCalibration 1 and 2 Screens 22 Troubleshooting ScreensTroubleshooting System Inputs Screen Troubleshooting System Outputs ScreenMembrane Test Screen Dynamic Dosing General Operating Cycle, Dynamic DosingSelect a Component B Restrictor Size B Control Range with Properly Sized Restrictor Pressure Too High Pressure Too Low Pressure B PressureSystem Alarms System ErrorsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle System Alarm/Advisory/Record Codes Error CodesAlarm and Description Cause Solution Alarm TroubleshootingCommunication Error USB Communication ErrorEQU2 PreMix Error Alarm and Description Cause Solution SFA1 or SFB1Pneumatic Schematic, page 66 or PreFill ErrorAlready about equal, verify that com Ratio Low ErrorQDB1 QDA1Dose Time Error Alarm and Description Cause Solution QTA1 or QTB1Leak Error Linear Sensor ErrorDiving/Cavitation Error Alarm and Description Cause Solution DDA1 or DDB1Park Error Stall Up ErrorDynamic Dosing Restrictor Selection Graphs ExampleRestrictor Sizes Size Code Orifice Size Flow Rate cc/min Detail View Differential Pressure between a and B500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 System Pneumatic Schematic SchematicsNon-Hazardous Location Pneumatic SchematicAIR Flow Switch SIG Fluid J4CONTROL Module Hazardous Location Electrical SchematicPower Supply Non-Hazardous Electrical Schematic Merkur Merkur Bellows Dimensions and MountingProMix 2KE Metric Technical DataOn-ratio accuracy Noise levelGraco Information Graco Standard Warranty