Dynamic Dosing Restrictor Selection Graphs
Dynamic Dosing Restrictor Selection Graphs
Use the graphs on pages 61- 65 as a guide to determine the correct restrictor size for your desired flow and mate- rial viscosity. Table 4 lists the available restrictor sizes.
Example:
Application: air spray system with a 5:1 mix ratio
Fluid Supply: 1:1 pumps at 100 psi (7 bar, 0.7 MPa)
Flow Rate: 300 cc/min at the gun
Select the Restrictor Size: choose either the 0.040 or 0.070 orifice, to ensure that the pressure differen- tial is not more than
•If the viscosity of component B is lower than the vis- cosity of the chart used for selection you may need to use a smaller restrictor or decrease the pressure differential.
•If the viscosity of component B is higher than the viscosity of the chart used for selection you may need to use a larger restrictor or increase the pres- sure differential.
•In systems using an
Table 4: Restrictor Sizes
Size Code | Orifice Size | Part No. |
|
|
|
2* | 0.020 | 15U936 |
|
|
|
3* | 0.030 | 15U937 |
|
|
|
4* | 0.040 | 15U938 |
|
|
|
5✓ | 0.050 | 15U939 |
|
|
|
6✓ | 0.060 | 15U940 |
|
|
|
7* | 0.070 | 15U941 |
|
|
|
8✓ | 0.080 | 16D554 |
|
|
|
*These restrictors are included in Injection Kit 15U955.
✓These restrictors are optional sizes, not included in the Injection Kit.