System Errors
Alarm and Description | Cause | Solution | |
|
|
| |
SFA1 or SFB1 | Gun, line, or valve is plugged or stuck. | Check components and clean, repair, | |
PreMix Error |
| or replace as necessary. | |
In systems with a gun flush |
|
| |
Pump(s) not working or out of fluid. | Refill fluid supply. Check and repair | ||
box, insufficient quantity of |
| pump. See pump manual for repair | |
resin/color (SFA1) or catalyst |
| procedures and replacement parts. | |
(SFB1) is detected during the |
|
| |
Air lines or solenoids are plumbed incor- | Check air line path. See System | ||
rectly or solenoids are not working. | Pneumatic Schematic, page 66 or | ||
| |||
SHA1 or SHB1 |
| 67. Verify that solenoid is working. | |
|
| ||
Flow rate is too low. | Increase fluid pressure. | ||
PreFill Error | |||
Total PreFill sequence volume |
|
| |
is not reached for color |
|
| |
(SHA1) or catalyst (SHB1) |
|
| |
during the |
|
| |
sequence. |
|
| |
|
|
| |
SM | Gun Flush Box is not triggering gun. | Verify trigger is being pulled. Adjust | |
MixFill Start Error |
| as needed. | |
In systems with a gun flush |
|
| |
Line or gun is plugged or restricted. | Clean line, tip, or filter. | ||
box, insufficient volume of |
|
| |
Flow rate is too low. | Increase fluid pressure or decrease | ||
mixed material is detected | |||
| restriction. | ||
during the |
| ||
|
| ||
Valve is stuck. | Clean valve or verify that solenoid is | ||
sequence. | |||
|
| triggering valve properly. | |
SN |
|
| |
MixFill Complete Error |
|
| |
Insufficient volume of mixed |
|
| |
material is detected during the |
|
| |
|
| ||
|
|
| |
QPD1 or QPD2 | Have not sprayed enough volume to keep | Purge the mixed material line. See | |
Potlife Error | fresh mixed fluid in the mix manifold, hose, | page 33. | |
Potlife has been exceeded for | and gun. | Check that hose length and diameter | |
the mixed material for Gun 1 |
| ||
(QPD1) or Gun 2 (QPD2). |
| have been entered correctly. See | |
|
| Configure 2 (Screen 19), page 43. | |
|
| Spray the required volume to restart | |
|
| the potlife timer. | |
|
|
|
3A0868G | 55 |