System Errors
Alarm and Description | Cause | Solution | |
|
|
| |
DDA1 or DDB1 | Fluid supply is empty. | Refill fluid supply system. | |
Diving/Cavitation Error |
|
| |
Displacement pump is not seating properly. | Rebuild displacement pump and | ||
Pump A (DDA1) or Pump B | |||
| replace packings, balls, and seats. | ||
(DDB1) is diving or cavitating. |
| ||
|
| ||
Air in fluid supply system. | Tighten all fittings. | ||
| |||
|
|
| |
EFA1 or EFB1 | Gun not open. | Trigger gun and allow fluid to flow | |
Park Error |
| while pump is attempting to park. | |
Pump A (EFA1) or Pump B |
|
| |
Fluid lines plugged. | Check and clear all fluid lines, gun tip, | ||
(EFB1) does not park (does |
| and the mix manifold. | |
not reach bottom change- |
|
| |
Dispense valve malfunction. | Clean or rebuild dispense valve. Ver- | ||
over). | |||
| ify that solenoid is operational. Clear | ||
|
| ||
|
| air lines to valve. | |
|
|
| |
DFA1 or DFB1 | Displacement pump is not seating properly. | Rebuild displacement pump and | |
Stall Up Error |
| replace packings, balls, and seats. | |
Pump A (DFA1) or Pump B |
|
| |
Dispense valve not seating/sealing. | Replace needle/seat on dispense | ||
(DFB1) does not stall up dur- |
| valve. | |
ing the pump calibration and |
|
| |
stall test (keeps moving up |
|
| |
when dosing valve is closed). |
|
| |
|
|
| |
DGA1 or DGB1 | Displacement pump is not seating properly. | Rebuild displacement pump and | |
Stall Down Error |
| replace packings, balls, and seats. | |
Pump A (DGA1) or Pump B |
|
| |
Dispense valve not seating/sealing. | Replace needle/seat on dispense | ||
(DGB1) does not stall down |
| valve. | |
during the pump calibration |
|
| |
and stall test (keeps moving |
|
| |
down when dosing valve is |
|
| |
closed). |
|
| |
|
|
| |
DHA1 or DHB1 | Displacement pump is not seating properly. | Rebuild displacement pump and | |
No Stall Error |
| replace packings, balls, and seats. | |
Pump A (DHA1) or Pump B |
|
| |
Dispense valve not seating/sealing. | Replace needle/seat on dispense | ||
(DHB1) does not stall in either |
| valve. | |
direction during the pump cali- |
|
| |
bration and stall test (keeps |
|
| |
moving when dosing valve is |
|
| |
closed). |
|
| |
|
|
|
3A0868G | 59 |