Graco 3A0868G Recipe 1-1 Screen Recipe 1-2 Screen, Configure 3 Screen 20 and Configure 4 Screen

Page 44

Setup Mode Details

USB log language

Date

format

Password

Date

Backlight

timer

Time

Configure 3

 

Distance

 

units

Pressure

 

Volume

units

 

 

units

 

 

Configure 4

 

Home

FIG. 39. Configure 3 (Screen 20) and Configure 4 (Screen 21)

Recipe 1-1 (Screen 28)

Recipe 1-2 (Screen 29)

Note about Settings of 0: If a Flush time is set to 0,

that valve will not flush.

Recipe 1-2 (Screen 29) includes timers for first, second and third flush:

First flush: Always an A side purge, using the A side flush material from the A purge valve.

Second flush: Always a B side purge, using the B side flush material from the B purge valve.

Third flush: User settable to run the A purge valve or the B purge valve for any required additional flush, as selected in the dropdown for the third flush source (A or B).

All flush times are settable from 0 to 240 seconds. Set flush time to 0 seconds to skip a flush in the sequence. For example, to skip the first flush (A side purge), enter 0 seconds. The system goes immediately to the second flush, followed by the third flush as user defined.

thirde of 0flushsecondswith thetoskipA purgea flushvalve.Forforexample,30 secondsenter. 0 seconds for A, 30 seconds for B, 30 seconds for the third flush time, and select A for the third flush source. The system will skip the first A flush, go directly to the second flush with the B purge valve for 30 seconds followed by the

Note about Settings of 0: If Ratio is set to 0, the sys- tem will dispense the A material only. If Potlife Time is set to 0, the potlife alarm is disabled.

Recipe 1-1 (Screen 28) displays if is selected on Setup Home (Screen 17). The Recipe Screens allow the user to set up the basic recipe. Recipe 1-1 (Screen 28) includes the ratio of Material A to Material B (0 to 30), ratio tolerance (1 to 99 percent), and potlife time (0 to

First flush time (A purge)

Recipe number

Second flush time (B purge)

Third flush time (uses material set in next field)

Third flush source

Home

240 minutes).

Recipe

numberPotlife timer

Ratio

Ratio tolerance

Home

FIG. 40. Recipe 1-1 (Screen 28)

FIG. 41. Recipe 1-2 (Screen 29)

Press to highlight the desired field and press

to select. Press to move between dig-

its. Press to change a digit. Press when field is correct.

Press to toggle between the Recipe screens.

Press to return to Setup Home (Screen 17).

44

3A0868G

Image 44
Contents ProMix 2KE Contents Series Ratio Pumps Psi MPa, bar Port Approvals ModelsUSB Manual Description Related ManualsModels Electric Shock Hazard Fire and Explosion HazardSpecial Conditions for Safe USE Intrinsic Safety Skin Injection HazardEquipment Misuse Hazard Moving Parts HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Installation OverviewUsage Component Identification and DefinitionIntrinsically Safe Installation Requirements Hazardous Location InstallationNon-Hazardous Locations Display Module Air SupplyRequirements Air regulator and bleed-type shutoff valveFluid Connections Fluid SupplyAir Connections SVB DVB SVA DVAKey Tubing Chart and Diagrams Used only on is modelsGFB1-A ATOM-1 ATOM-2 Power Connection non-IS units only ElectricalGrounding Grounding Display Module DisplayIG . Display Module Key FunctionIcon Key Run Mode Setup ModeTroubleshooting Screen SummaryScreen User Input Range/Options Default Ranges for User InputsErrors Pump ControlHome RunSet-Up Home Password Configure RecipeMaintenance Calibration Set-Up HomeMembrane Test System Outputs Set-Up Home System InputsSystem Outputs Power On Initial System SetupBasic Operation Pre-Operation TasksPrime the System Pump Calibration Calibrate the pumpSpraying PurgingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Mixed Material Purging Fluid Supply SystemSolenoid Valves in Control Box Pressure Relief Procedure Valve SettingsLock Mode ShutdownError Log Use of Optional USB ModuleUSB Logs Job LogSetup Sample Error LogUSB Port Download ProcedureRecommended USB Flash Drives Run Mode Details Run Mix Spray ScreenRun Home Screen Run Mix Batch ScreenRun Job Number Screen Run Log Errors ScreensRun Mix Totals Screen Run Pump Control Screen Run Pump Control ScreenSetup Home Screen Setup Mode DetailsPassword Screen Configure 1-4 Screens Confirm Change of System TypeConfigure 3 Screen 20 and Configure 4 Screen Recipe 1-1 Screen Recipe 1-2 ScreenMaintenance 1-3 Screens Maintenance RecommendationsRecommended Maintenance Component FrequencyTroubleshooting Screens Calibration 1 and 2 Screens 22Membrane Test Screen Troubleshooting System Inputs ScreenTroubleshooting System Outputs Screen Select a Component B Restrictor Size Dynamic DosingGeneral Operating Cycle, Dynamic Dosing Pressure Too High Pressure Too Low Pressure B Pressure B Control Range with Properly Sized RestrictorSystem Errors System AlarmsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle Error Codes System Alarm/Advisory/Record CodesAlarm Troubleshooting Alarm and Description Cause SolutionCommunication Error USB Communication ErrorEQU2 Alarm and Description Cause Solution SFA1 or SFB1 PreMix ErrorPneumatic Schematic, page 66 or PreFill ErrorRatio Low Error Already about equal, verify that comQDA1 QDB1Alarm and Description Cause Solution QTA1 or QTB1 Dose Time ErrorLeak Error Linear Sensor ErrorAlarm and Description Cause Solution DDA1 or DDB1 Diving/Cavitation ErrorPark Error Stall Up ErrorRestrictor Sizes Size Code Orifice Size Dynamic Dosing Restrictor Selection GraphsExample Differential Pressure between a and B Flow Rate cc/min Detail View500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 Schematics System Pneumatic SchematicPneumatic Schematic Non-Hazardous LocationAIR Flow Switch SIG Hazardous Location Electrical Schematic Fluid J4CONTROL ModulePower Supply Non-Hazardous Electrical Schematic Dimensions and Mounting Merkur Merkur BellowsTechnical Data ProMix 2KE MetricOn-ratio accuracy Noise levelGraco Standard Warranty Graco Information