System Errors
Alarm and Description | Cause | Solution | |
|
|
| |
QTA1 or QTB1 | System is in Mix mode and gun is only par- | Fully trigger the gun. | |
Dose Time Error | tially triggered, allowing air but no fluid to |
| |
The gun trigger is active, but | pass through gun. |
| |
no A pump (QTA1) or B pump |
|
| |
Fluid flow rate is too low. | Increase flow rate. | ||
(QTB1) movement is detected |
|
| |
Slow actuation of component A or B valves. | See Ratio Low Error and Ratio High | ||
during the dose time selected. |
| Error, pages | |
|
| ||
|
|
| |
| A or B pump has no air pressure. | Verify that main air supply is turned | |
|
| on and valves are open. | |
|
|
| |
| There is an air leak downstream from the | Check the air lines for leaks and | |
| air flow switch. | repair. | |
|
|
| |
| The air flow switch is stuck open. | Clean or replace air flow switch. | |
|
|
| |
QLAX or QLBX | A or B dose valve leak | Replace valve needle and seat. | |
Leak Error |
|
| |
A or B pump is not seating and continues | Replace pump packings, balls, and | ||
Pump A (QLAX) or Pump B | |||
to move/creep. | seats. | ||
(QLBX) is running with all | |||
|
| ||
valves closed. |
|
| |
|
|
| |
DJA1 or DJB1 | Sensor not recognized by system. | Verify that sensor is plugged in. Verify | |
Linear Sensor Error |
| that sensor and AFCM are opera- | |
System does not detect the |
| tional. Verify cable connections. | |
pump A (DJA1) or pump B |
| Replace any malfunctioning compo- | |
(DJB1) linear position sensor, |
| nent. | |
or has an invalid position read- |
|
| |
Magnet fell off. | Replace magnet and holder on top | ||
ing. |
| side of air motor piston. | |
|
|
| |
| Sensor readings are out of range. | Verify that the sensor is threaded | |
|
| down | |
|
| completely. | |
|
|
| |
DKA1 or DKB1 | Reed switch installed backward. | Flip reed switch 180 degrees to align | |
Reed Switch Error |
| with magnet in air valve. | |
System does not detect the |
|
| |
Reed switches are stuck, or both reed | Verify cable is connected on both | ||
pump A (DKA1) or Pump B | switches are on at once | ends. Verify that reed switch, cable, | |
(DKB1) reed switch sensor, or |
| and AFCM are operational. Replace | |
detects an invalid state. |
| any malfunctioning component. | |
|
|
| |
| Magnet in air valve not functioning prop- | Verify that magnet is installed prop- | |
| erly. | erly and is operational. | |
|
|
| |
P4A1 or P4B1 | Pump air pressure is set too high. | Reduce pressure on air supply to sys- | |
Pressure High Error |
| tem or pumps. | |
System detects a high pres- |
|
| |
Thermal expansion occurring in lines. | Relieve pressure if system has been | ||
sure reading on pump A |
| idle. Decrease environmental | |
(P4A1) or pump B (P4B1). |
| temperature. | |
|
|
| |
| Pressure transducer malfunction. | Replace transducer. Verify that cable | |
|
| and AFCM are operational. | |
P6A1 or P6B1 | Pressure transducer malfunction. | Replace transducer. Verify that cable | |
Pressure Transducer Error |
| and AFCM are operational. | |
System does not detect pres- |
|
| |
sure transducer A (P6A1) or |
|
| |
pressure transducer B (P6B1). |
|
| |
|
|
|
58 | 3A0868G |