Warnings
WARNING
INTRINSIC SAFETY
Intrinsically safe equipment that is installed improperly or connected to
•Only models with model numbers
•Be sure your installation complies with national, state, and local codes for the installation of electrical apparatus in a Class I, Group D, Division 1 (North America) or Class I, Zones 1 and 2 (Europe) Hazardous Location, including all of the local safety fire codes, NFPA 33, NEC 500 and 516, and OSHA 1910.107.
•To help prevent fire and explosion:
•Do not install equipment approved only for a
•Do not substitute system components as this may impair intrinsic safety.
•Equipment that comes in contact with the intrinsically safe terminals must be rated for Intrinsic Safety. This includes DC voltage meters, ohmmeters, cables, and connections. Remove the unit from the hazardous area when troubleshooting.
•The equipment is intrinsically safe when no external electrical components are connected to it.
•Do not connect, download, or remove USB device unless unit is removed from the hazardous (explosive atmosphere) location.
SKIN INJECTION HAZARD
• Do not spray without tip guard and trigger guard installed.
•Engage trigger lock when not spraying.
•Do not point gun at anyone or at any part of the body.
•Do not put your hand over the spray tip.
•Do not stop or deflect leaks with your hand, body, glove, or rag.
•Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.
•Tighten all fluid connections before operating the equipment.
•Check hoses and couplings daily. Replace worn or damaged parts immediately.
6 | 3A0868G |