Graco 3A0868G important safety instructions Error Codes, System Alarm/Advisory/Record Codes

Page 52

System Errors

Error Codes

Table 3: System Alarm/Advisory/Record Codes

Code

Description

Details

 

 

 

Alarm Codes - Alarm sounds, system stops, icon dis- plays until problem is solved and alarm is cleared.

CA

Communication Error

53

 

 

 

CAU1

USB Communication Error

53

 

 

 

EQU2

USB Installed when not in Standby

54

 

 

 

SG

Gun Flush Box Error

54

 

 

 

SAD1

Atomizing Air During Purge - Gun 1

54

SAD2

Atomizing Air During Purge - Gun 2

 

 

 

 

SFA1

PreMix Error - Color

55

SFB1

PreMix Error - Catalyst

 

 

 

 

SHA1

PreFill Error - Color

55

SHB1

PreFill Error - Catalyst

 

 

 

 

SM

MixFill Start Error

55

 

 

 

SN

MixFill Complete Error

55

 

 

 

QPD1

Potlife Error - Gun 1

55

QPD2

Potlife Error - Gun 2

 

 

 

 

R1

Ratio Low Error

56

 

 

 

R4

Ratio High Error

57

 

 

 

QDA1

Overdose A, B Dose too Short

57

QDB1

Overdose B, A Dose too Short

 

 

 

 

QTA1

Dose Time A Error

58

QTB1

Dose Time B Error

 

 

 

 

QLAX

Leak Error A

58

QLBX

Leak Error B

 

 

 

 

DJA1

Linear Sensor Error - Pump A

58

DJB1

Linear Sensor Error - Pump B

 

 

 

 

DKA1

Reed Switch Error - Pump A

58

DKB1

Reed Switch Error - Pump B

 

 

 

 

P4A1

Pressure High Error - Pump A

58

P4B1

Pressure High Error - Pump B

 

 

 

 

P6A1

Pressure Transducer Error - Pump A

58

P6B1

Pressure Transducer Error - Pump B

 

 

 

 

DDA1

Diving/Cavitation Error - Pump A

59

DDB1

Diving/Cavitation Error - Pump B

 

 

 

 

EFA1

Park Error - Pump A

59

EFB1

Park Error - Pump B

 

 

 

 

DFA1

Stall Up Error - Pump A

59

DFB1

Stall Up Error - Pump B

 

 

 

 

DGA1

Stall Down Error - Pump A

59

DGB1

Stall Down Error - Pump B

 

 

 

 

DHA1

No Stall Error - Pump A

59

DHB1

No Stall Error - Pump B

 

 

 

 

Table 3: System Alarm/Advisory/Record Codes

Code

Description

Details

 

 

 

Advisory Codes - No alarm, system continues operat- ing, icon displays on active screen until cleared

MAA1

Pump A maintenance due

N/A

 

 

 

MAB1

Pump B maintenance due

N/A

 

 

 

MEA1

Mix valve A maintenance due

N/A

 

 

 

MEB1

Mix valve B maintenance due

N/A

 

 

 

MESA

Solvent valve A maintenance due

N/A

 

 

 

MESB

Solvent valve B maintenance due

N/A

 

 

 

MGA1

Fluid Filter A maintenance due

N/A

 

 

 

MGB1

Fluid Filter B maintenance due

N/A

 

 

 

MGP1

Air Filter maintenance due

N/A

 

 

 

ES

System defaults loaded

N/A

 

 

 

Record Codes - No alarm, system continues operating, no icon displays on active screen.

EL

System powered on

N/A

 

 

 

EC

System setup changed

N/A

 

 

 

EP

Pump park operation completed

N/A

 

 

 

ET

System performed an autodump after

N/A

 

a potlife

 

 

 

 

EQU1

USB Drive connected while in Standby

N/A

 

 

 

52

3A0868G

Image 52
Contents ProMix 2KE Contents USB ModelsSeries Ratio Pumps Psi MPa, bar Port Approvals Models Related ManualsManual Description Special Conditions for Safe USE Fire and Explosion HazardElectric Shock Hazard Intrinsic Safety Skin Injection HazardEquipment Misuse Hazard Moving Parts HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Installation OverviewUsage Component Identification and DefinitionIntrinsically Safe Installation Requirements Hazardous Location InstallationNon-Hazardous Locations Display Module Air SupplyRequirements Air regulator and bleed-type shutoff valveAir Connections Fluid SupplyFluid Connections Key SVA DVASVB DVB Tubing Chart and Diagrams Used only on is modelsGFB1-A ATOM-1 ATOM-2 Power Connection non-IS units only ElectricalGrounding Grounding Display Module DisplayIG . Display Module Key FunctionIcon Key Run Mode Setup ModeTroubleshooting Screen SummaryScreen User Input Range/Options Default Ranges for User InputsErrors Pump ControlHome RunSet-Up Home Password Configure RecipeMaintenance Calibration Set-Up HomeSystem Outputs System Outputs Set-Up Home System InputsMembrane Test Power On Initial System SetupBasic Operation Pre-Operation TasksPrime the System Pump Calibration Calibrate the pumpSpraying PurgingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Mixed Material Purging Fluid Supply SystemSolenoid Valves in Control Box Pressure Relief Procedure Valve SettingsLock Mode ShutdownError Log Use of Optional USB ModuleUSB Logs Job LogSetup Sample Error LogRecommended USB Flash Drives Download ProcedureUSB Port Run Mode Details Run Mix Spray ScreenRun Home Screen Run Mix Batch ScreenRun Mix Totals Screen Run Log Errors ScreensRun Job Number Screen Run Pump Control Screen Run Pump Control ScreenPassword Screen Setup Mode DetailsSetup Home Screen Configure 1-4 Screens Confirm Change of System TypeConfigure 3 Screen 20 and Configure 4 Screen Recipe 1-1 Screen Recipe 1-2 ScreenMaintenance 1-3 Screens Maintenance RecommendationsRecommended Maintenance Component FrequencyTroubleshooting Screens Calibration 1 and 2 Screens 22Troubleshooting System Outputs Screen Troubleshooting System Inputs ScreenMembrane Test Screen General Operating Cycle, Dynamic Dosing Dynamic DosingSelect a Component B Restrictor Size Pressure Too High Pressure Too Low Pressure B Pressure B Control Range with Properly Sized RestrictorSystem Errors System AlarmsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle Error Codes System Alarm/Advisory/Record CodesAlarm Troubleshooting Alarm and Description Cause SolutionCommunication Error USB Communication ErrorEQU2 Alarm and Description Cause Solution SFA1 or SFB1 PreMix ErrorPneumatic Schematic, page 66 or PreFill ErrorRatio Low Error Already about equal, verify that comQDA1 QDB1Alarm and Description Cause Solution QTA1 or QTB1 Dose Time ErrorLeak Error Linear Sensor ErrorAlarm and Description Cause Solution DDA1 or DDB1 Diving/Cavitation ErrorPark Error Stall Up ErrorExample Dynamic Dosing Restrictor Selection GraphsRestrictor Sizes Size Code Orifice Size Differential Pressure between a and B Flow Rate cc/min Detail View500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 Schematics System Pneumatic SchematicPneumatic Schematic Non-Hazardous LocationAIR Flow Switch SIG Hazardous Location Electrical Schematic Fluid J4CONTROL ModulePower Supply Non-Hazardous Electrical Schematic Dimensions and Mounting Merkur Merkur BellowsTechnical Data ProMix 2KE MetricOn-ratio accuracy Noise levelGraco Standard Warranty Graco Information