Use of Optional USB Module
Use of Optional USB Module
USB Logs
Job Log 1
See example in FIG. 22. The job log records total vol- umes for each job that the system performs, up to 2000. It records the date, time, user number, job number, total A volume, total B volume, and mix ratio. Job total vol- umes are in cubic centimeters. A log entry is made when a new job is initiated, which occurs when batch totals are cleared, or when the job number is incre- mented from Run Job Number (Screen 38). Job infor- mation is displayed on the Display Module only through use of the optional USB Module.
NOTE: User Number, Ratio, and Alarm
Error Log 2
See example in FIG. 23. The error log records all errors generated by the system, up to 500. It records the date, time, error number, error code, and error type for each error that occurs. Without the USB, the user can access the 50 most recent errors via the Display Module.
NOTE: For both the Job Log and the Error Log, when the log is full, new data automatically overwrites old data. When data in either log is downloaded via the USB, it remains in the module until it is overwritten.