Graco 3A0868G important safety instructions Grounding

Page 20

Installation

10

1

Key:

1 Control Box ground screw

2 Control Box ground wire

3 Pump B ground screw

4 Pump B ground wire

5 Pump A ground screw

6 Pump A ground wire

7 Gun Flush Box ground screw

8 Gun Flush Box ground wire

9 True Earth Ground - check your

2

local code for requirements.

5

6

9

FIG. 9. Grounding

10Power cable, Display Module/Control Box

3

4

7

8

ti16467a

20

3A0868G

Image 20
Contents ProMix 2KE Contents Series Ratio Pumps Psi MPa, bar Port Approvals ModelsUSB Manual Description Related ManualsModels Electric Shock Hazard Fire and Explosion HazardSpecial Conditions for Safe USE Intrinsic Safety Skin Injection HazardEquipment Misuse Hazard Moving Parts HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Installation OverviewUsage Component Identification and DefinitionIntrinsically Safe Installation Requirements Hazardous Location InstallationNon-Hazardous Locations Display Module Air SupplyRequirements Air regulator and bleed-type shutoff valveFluid Connections Fluid SupplyAir Connections SVB DVB SVA DVAKey Tubing Chart and Diagrams Used only on is models GFB1-A ATOM-1 ATOM-2 Power Connection non-IS units only ElectricalGrounding Grounding Display Module DisplayIG . Display Module Key FunctionIcon Key Run Mode Setup ModeTroubleshooting Screen SummaryScreen User Input Range/Options Default Ranges for User InputsErrors Pump ControlHome RunSet-Up Home Password Configure RecipeMaintenance Calibration Set-Up HomeMembrane Test System Outputs Set-Up Home System InputsSystem Outputs Power On Initial System SetupBasic Operation Pre-Operation TasksPrime the System Pump Calibration Calibrate the pumpSpraying PurgingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Mixed Material Purging Fluid Supply SystemSolenoid Valves in Control Box Pressure Relief Procedure Valve SettingsLock Mode ShutdownError Log Use of Optional USB ModuleUSB Logs Job LogSetup Sample Error LogUSB Port Download ProcedureRecommended USB Flash Drives Run Mode Details Run Mix Spray ScreenRun Home Screen Run Mix Batch ScreenRun Job Number Screen Run Log Errors ScreensRun Mix Totals Screen Run Pump Control Screen Run Pump Control ScreenSetup Home Screen Setup Mode DetailsPassword Screen Configure 1-4 Screens Confirm Change of System TypeConfigure 3 Screen 20 and Configure 4 Screen Recipe 1-1 Screen Recipe 1-2 ScreenMaintenance 1-3 Screens Maintenance RecommendationsRecommended Maintenance Component FrequencyTroubleshooting Screens Calibration 1 and 2 Screens 22Membrane Test Screen Troubleshooting System Inputs ScreenTroubleshooting System Outputs Screen Select a Component B Restrictor Size Dynamic DosingGeneral Operating Cycle, Dynamic Dosing Pressure Too High Pressure Too Low Pressure B Pressure B Control Range with Properly Sized RestrictorSystem Errors System AlarmsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle Error Codes System Alarm/Advisory/Record CodesAlarm Troubleshooting Alarm and Description Cause SolutionCommunication Error USB Communication ErrorEQU2 Alarm and Description Cause Solution SFA1 or SFB1 PreMix ErrorPneumatic Schematic, page 66 or PreFill ErrorRatio Low Error Already about equal, verify that comQDA1 QDB1Alarm and Description Cause Solution QTA1 or QTB1 Dose Time ErrorLeak Error Linear Sensor ErrorAlarm and Description Cause Solution DDA1 or DDB1 Diving/Cavitation ErrorPark Error Stall Up ErrorRestrictor Sizes Size Code Orifice Size Dynamic Dosing Restrictor Selection GraphsExample Differential Pressure between a and B Flow Rate cc/min Detail View500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 Schematics System Pneumatic SchematicPneumatic Schematic Non-Hazardous LocationAIR Flow Switch SIG Hazardous Location Electrical Schematic Fluid J4CONTROL ModulePower Supply Non-Hazardous Electrical Schematic Dimensions and Mounting Merkur Merkur BellowsTechnical Data ProMix 2KE MetricOn-ratio accuracy Noise levelGraco Standard Warranty Graco Information