Dose Size - the amount of resin (A) and catalyst (B) that is dispensed into an integrator.

Dose Time Alarm - the amount of time that is allowed for a dose to occur before an alarm occurs.

Dynamic Dosing - Component A dispenses constantly. Component B dispenses intermittently in the necessary volume to attain the mix ratio.

Grand Total - a non-resettable value that shows the total amount of material dispensed through the system.

Intrinsically Safe (IS) - refers to the ability to locate cer- tain components in a hazardous location.

Idle - if the gun is not triggered for 2 minutes the system enters Idle mode. Trigger the gun to resume operation.

Batch Total - a resettable value that shows the amount of material dispensed through the system for one batch. A batch is complete when the user resets the batch counter to zero.

Mix - when cross-linking of the resin (A) and catalyst (B) occurs.

Overdose Alarm - when either the resin (A) or catalyst

(B)component dispenses too much material and the system cannot compensate for the additional material.

Potlife Time - the amount of time before a material becomes unsprayable.

Potlife Volume - the amount of material that is required to move through the mix manifold, hose, and applicator before the potlife timer is reset.

Pump Calibration Factor - the amount of material dis- pensed per inch of pump travel.

Purge - when all mixed material is flushed from the sys- tem.

Purge Time - the amount of time required to flush all mixed material from the system.

Ratio Tolerance - the settable percent of acceptable variance that the system will allow before a ratio alarm occurs.

Standby - refers to the status of the system.

3A0868G

9

Image 9
Contents ProMix 2KE Contents Models USBSeries Ratio Pumps Psi MPa, bar Port Approvals Related Manuals ModelsManual Description Fire and Explosion Hazard Special Conditions for Safe USEElectric Shock Hazard Skin Injection Hazard Intrinsic SafetyMoving Parts Hazard Equipment Misuse HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Overview InstallationUsage Component Identification and DefinitionHazardous Location Installation Intrinsically Safe Installation RequirementsNon-Hazardous Locations Air Supply Display ModuleRequirements Air regulator and bleed-type shutoff valveFluid Supply Air ConnectionsFluid Connections SVA DVA KeySVB DVB Used only on is models Tubing Chart and DiagramsGFB1-A ATOM-1 ATOM-2 Electrical Power Connection non-IS units onlyGrounding Grounding Display Display ModuleIG . Display Module Key FunctionIcon Key Setup Mode Run ModeTroubleshooting Screen SummaryRanges for User Inputs Screen User Input Range/Options DefaultPump Control ErrorsHome RunRecipe Set-Up Home Password ConfigureCalibration Set-Up Home MaintenanceSystem Outputs Set-Up Home System Inputs System OutputsMembrane Test Initial System Setup Power OnBasic Operation Pre-Operation TasksPrime the System Calibrate the pump Pump CalibrationPurging SprayingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Fluid Supply System Purging Mixed MaterialSolenoid Valves in Control Box Valve Settings Pressure Relief ProcedureLock Mode ShutdownUse of Optional USB Module Error LogUSB Logs Job LogSample Error Log SetupDownload Procedure Recommended USB Flash DrivesUSB Port Run Mix Spray Screen Run Mode DetailsRun Home Screen Run Mix Batch ScreenRun Log Errors Screens Run Mix Totals ScreenRun Job Number Screen Run Pump Control Screen Run Pump Control ScreenSetup Mode Details Password ScreenSetup Home Screen Confirm Change of System Type Configure 1-4 ScreensRecipe 1-1 Screen Recipe 1-2 Screen Configure 3 Screen 20 and Configure 4 ScreenMaintenance Recommendations Maintenance 1-3 ScreensRecommended Maintenance Component FrequencyCalibration 1 and 2 Screens 22 Troubleshooting ScreensTroubleshooting System Inputs Screen Troubleshooting System Outputs ScreenMembrane Test Screen Dynamic Dosing General Operating Cycle, Dynamic DosingSelect a Component B Restrictor Size B Control Range with Properly Sized Restrictor Pressure Too High Pressure Too Low Pressure B PressureSystem Alarms System ErrorsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle System Alarm/Advisory/Record Codes Error CodesAlarm and Description Cause Solution Alarm TroubleshootingCommunication Error USB Communication ErrorEQU2 PreMix Error Alarm and Description Cause Solution SFA1 or SFB1Pneumatic Schematic, page 66 or PreFill ErrorAlready about equal, verify that com Ratio Low ErrorQDB1 QDA1Dose Time Error Alarm and Description Cause Solution QTA1 or QTB1Leak Error Linear Sensor ErrorDiving/Cavitation Error Alarm and Description Cause Solution DDA1 or DDB1Park Error Stall Up ErrorDynamic Dosing Restrictor Selection Graphs ExampleRestrictor Sizes Size Code Orifice Size Flow Rate cc/min Detail View Differential Pressure between a and B500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 System Pneumatic Schematic SchematicsNon-Hazardous Location Pneumatic SchematicAIR Flow Switch SIG Fluid J4CONTROL Module Hazardous Location Electrical SchematicPower Supply Non-Hazardous Electrical Schematic Merkur Merkur Bellows Dimensions and MountingProMix 2KE Metric Technical DataOn-ratio accuracy Noise levelGraco Information Graco Standard Warranty