System Errors

Alarm and Description

Cause

Solution

 

 

 

R4

There is too little restriction in the system.

• Check that the system is fully

Ratio High Error

 

loaded with material.

The mix ratio is higher than

 

• Check that the supply pump’s

the set tolerance for an A to B

 

 

cycle rate is set properly.

component volume compari-

 

 

 

son.

 

• Check that the spray tip/nozzle is

 

 

properly sized for the flow and

 

 

application, and that it is not

 

 

worn.

 

 

• Check that the fluid regulator is

 

 

set properly.

 

 

 

 

If the alarm occurs during start up, after

Restrict gun needle travel to slow

 

purging, the flow rate was probably too

down the initial fluid delivery rate until

 

high.

fluid hoses are loaded with material.

 

 

 

 

If the alarm occurred after you were spray-

Adjust component A and B fluid sup-

 

ing for some time, the pressures from the

ply regulator pressures until they are

 

fluid supplies could be unbalanced.

about equal. If the pressures are

 

 

already about equal, verify that com-

 

 

ponent A and B dose valves are oper-

 

 

ating properly.

 

 

 

 

Slow actuation of the component A or B

Manually operate the Dose Valve A

 

valves. This can be caused by:

and B solenoid valves to check oper-

 

 

ation.

 

 

 

 

• Air pressure to the valve actuators is

• Increase air pressure. Air pres-

 

too low.

sure must be 75-120 psi

 

 

(0.52-0.84 MPa, 5.2-8.4 bar); 120

 

 

psi is recommended.

 

 

 

 

• Something is restricting the solenoid or

• There may be dirt or moisture in

 

tubing and interrupting valve actuation

the air supply. Filter appropri-

 

air.

ately.

 

 

 

 

• Dose Valve B is turned in too far.

• Refer to Valve Settings, page

 

Dose Valve A is open too far.

35, for adjustment guidelines.

 

 

 

 

• Fluid pressure is high and air pressure

• Adjust air and fluid pressure. See

 

is low.

recommended air pressure

 

 

above.

 

 

 

QDA1

Valve seal or needle/seat are leaking.

Repair the valve.

Overdose A

 

 

Slow actuation of component A or B valves.

See Ratio Low Error and Ratio High

The A dose has overshot and,

 

Error, pages 56-57.

when combined with B, is too

 

 

Running a high mix ratio and a high flow

It may be necessary to restrict the

large for the mix manifold

rate.

flow rate through the component B

capacity.

 

dose valve by adjusting its hex nut.

QDB1

 

 

 

Overdose B

 

 

The B dose has overshot,

 

 

forcing an A dose that, when

 

 

combined with B, is too large

 

 

for the mix manifold capacity.

 

 

 

 

 

3A0868G

57

Image 57
Contents ProMix 2KE Contents Models USBSeries Ratio Pumps Psi MPa, bar Port Approvals Related Manuals ModelsManual Description Fire and Explosion Hazard Special Conditions for Safe USEElectric Shock Hazard Skin Injection Hazard Intrinsic SafetyMoving Parts Hazard Equipment Misuse HazardToxic Fluid or Fumes Hazard Personal Protective EquipmentImportant Two-Component Material Information Glossary of Terms Overview InstallationUsage Component Identification and DefinitionHazardous Location Installation Intrinsically Safe Installation RequirementsNon-Hazardous Locations Air Supply Display ModuleRequirements Air regulator and bleed-type shutoff valveFluid Supply Air ConnectionsFluid Connections SVA DVA KeySVB DVB Used only on is models Tubing Chart and DiagramsGFB1-A ATOM-1 ATOM-2 Electrical Power Connection non-IS units onlyGrounding Grounding Display Display ModuleIG . Display Module Key FunctionIcon Key Setup Mode Run ModeTroubleshooting Screen SummaryRanges for User Inputs Screen User Input Range/Options DefaultPump Control ErrorsHome RunRecipe Set-Up Home Password ConfigureCalibration Set-Up Home MaintenanceSystem Outputs Set-Up Home System Inputs System OutputsMembrane Test Initial System Setup Power OnBasic Operation Pre-Operation TasksPrime the System Calibrate the pump Pump CalibrationPurging SprayingBration 1 and 2 Screens 22 and 23, Purging Mixed Material Purging Fluid Supply SystemPurging Fluid Supply System Purging Mixed MaterialSolenoid Valves in Control Box Valve Settings Pressure Relief ProcedureLock Mode ShutdownUse of Optional USB Module Error LogUSB Logs Job LogSample Error Log SetupDownload Procedure Recommended USB Flash DrivesUSB Port Run Mix Spray Screen Run Mode DetailsRun Home Screen Run Mix Batch ScreenRun Log Errors Screens Run Mix Totals ScreenRun Job Number Screen Run Pump Control Screen Run Pump Control ScreenSetup Mode Details Password ScreenSetup Home Screen Confirm Change of System Type Configure 1-4 ScreensRecipe 1-1 Screen Recipe 1-2 Screen Configure 3 Screen 20 and Configure 4 ScreenMaintenance Recommendations Maintenance 1-3 ScreensRecommended Maintenance Component FrequencyCalibration 1 and 2 Screens 22 Troubleshooting ScreensTroubleshooting System Inputs Screen Troubleshooting System Outputs ScreenMembrane Test Screen Dynamic Dosing General Operating Cycle, Dynamic DosingSelect a Component B Restrictor Size B Control Range with Properly Sized Restrictor Pressure Too High Pressure Too Low Pressure B PressureSystem Alarms System ErrorsTo Clear Error and Restart Air Flow Switch AFS FunctionSystem Idle Warning Idle System Alarm/Advisory/Record Codes Error CodesAlarm and Description Cause Solution Alarm TroubleshootingCommunication Error USB Communication Error EQU2 PreMix Error Alarm and Description Cause Solution SFA1 or SFB1Pneumatic Schematic, page 66 or PreFill ErrorAlready about equal, verify that com Ratio Low ErrorQDB1 QDA1Dose Time Error Alarm and Description Cause Solution QTA1 or QTB1Leak Error Linear Sensor ErrorDiving/Cavitation Error Alarm and Description Cause Solution DDA1 or DDB1Park Error Stall Up ErrorDynamic Dosing Restrictor Selection Graphs ExampleRestrictor Sizes Size Code Orifice Size Flow Rate cc/min Detail View Differential Pressure between a and B500 1000 1500 2000 2500 3000 3500 4000 200 14 150 10 100 7 50 3.4 500 1000 Psi 40 2.8 30 2.1 20 1.4 10 0.7 500 1000 System Pneumatic Schematic SchematicsNon-Hazardous Location Pneumatic SchematicAIR Flow Switch SIG Fluid J4CONTROL Module Hazardous Location Electrical SchematicPower Supply Non-Hazardous Electrical Schematic Merkur Merkur Bellows Dimensions and MountingProMix 2KE Metric Technical DataOn-ratio accuracy Noise levelGraco Information Graco Standard Warranty